NOT TO SCALE
POR OF THE NE 1/4 OF THE SE 1/4 & THE SE 1/4 OF THE NE 1/4, ALL IN SEC. 10, TWP. 23 N., RGE. 5 E., W.M.
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR JOINT(S) (3/8" MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C-443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC.,
OR APPROVED EQUAL.
LADDER -POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX- PIPE S12E - 'E'
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN SHELF.
•A,
'B
'C'
48" MH
48"
6" MIN.
5'MIN V. 21" I.D.
54" MH
54"
8" MIN.
5.5" MIR 24" I.D.
60" MH
60"
8" MIN.
6" MIN. 42" Ml\. 30" LD.
NOTES:
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS,
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 401.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6, ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF
ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443,
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR
APPROVED EQUAL.
it. IN UNIMPROVED AREAS. MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12"
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE.
IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
PUBLIC WORKS STD. PLAN - 400.1
` + DEPARTMENT STANDARD SANITARY MANHOLE
SEPTEMBER 2011
MANHOLE FRAME AND COVER
PER DRAWING 401,
ADJUSTMENT RINGS (2" MIN.)
SEE NOTE 6
MORTAR JOINTS) (3/8" MIN.)
�i
SEE NOTE 5 4" MIN. TO
e 12" MAX.
v c
X
A+ 24„ ¢
v
9 - a u)
0 d
� m
N O
m Z
m
Q
o. -
X N
Q
"
>I
454"
71.
11(
SQ 9 p.
6..
NOTES:
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PLAN 401.
4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE.
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A
COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL
RF STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND,
USE OF SHIMS IS PROHIBITED.
7, SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER
MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL
BOOTS OR APPROVED EQUAL,
11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF
12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS
POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING.
�. PUBLIC WORKS SANITARY MANHOLE STD. PLAN - 400.2
DEPARTMENT SHALLOW SEPTEMBER 2011
BOLTHCLES - 3 PLCS
EQUALLY SPACED 12C'
APART ❑N 23 1/16' (586mm)
DIA B,C, (SEE DETAIL)
RENTO
\\ SEWER
�IqE IM ISA
COVER & FRAME
PLAN VIEW
2s• DIA.
C635mm] 1'
3/4' C25mm]
C19mm]
-54
8 3/4" L 2 1/2'
C222mm] 164mm]
TYP
COVER SECTION VIEW
26 1/2' DIA
C673mm]
25 1/4' DIA
1641mm] 1 1/16'
1/4' (6mm) DIA 127mm]
NEOPRENE GASKET
6'
C152 mm]
5/8' J 23 3/81 DIA CL ❑PEN
[16mm] 7594mm]
27 5/16' DIA
C694mm]
34 1/8' DIA
COVER BOTTOM VIEW
3) BLT SDC. (ALLEN HEAD)
5/8'-11 X 1.5 SS
\ RUBBER WASHER
EON BOLTING DETAIL
I/4'
C6mm] [27mm]
1/s• #
C3mm]
i/8'
CR3mm7
GASKET GROOVE DETAIL
C867mm] NOTES:
FRAME SECTION VIEW 1, ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL.
2. USE FRAME AND COVER FOR STORM (SPECIFY
"DRAIN" ON COVER), SANITARY (SPECIFY
"SEWER"), OR WATER (SPECIFY "WATER").
Y
STD. PLAN - 401
PUBLIC WORKS MANHOLE FRAME AND COVER
DEPARTMENT
DECEMBER 2008
0-14
�\
�LJ
>
<1J�
=;, IX
o�oJ�
RECESSED
LIFT POCKET
" - 11 N.C. SOCKET HD
SCREW 1 Ya" LONG
(BRONZE OR S.S.)
" x 2" RAISED PADS
�- 12 Y4"
14" �
2„ ye„
2„
y4„
2"
11"
12 Y4"
14"
CAST IRON RING AND COVER
2" A.C- 2'-0„
6" CONCRETE
CLASS 3000 SAND OR
EXPANDABLE
FCAM
WATER TIGHT
PLUG
45' (1/8) BEND
45' (1/8) BEND
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTES:
1. B" AND 6" CLEANOUTS ON SEWER MAINS SHALL BE EAST JORDAN IRON WORKS, INC.
No, M98 OR EQUAL. CLEAN OUT SHALL BE A WATER TIGHT ASSEMBLY.
2. IN UNIMPROVED AREAS, POUR A 1'-0" THICK, 2'-D" SQUARE
CONCRETE, CLASS 3000, PAD AROUND THE RING AND COVER.
STD. PLAN - 403.1
PUBLIC WORKS B OR 6 INCH CLEAN -OUT
+� + DEPARTMENT FOR SANITARY SEINER MAINS SEPTEMBER 2011
T ~
S
SANITARY SEWER NOTES AND SPECIFICATIONS
1. ALL *ORK AND WORK MATERIAL SHALL BE /N CONFORMANCE WITH TIME STANDARDS AND SPECIFICATIONS
OF 774E CITY OF RENTON PLANN/NG/BUILD/NG11PUBLIC WORKS DEPARTMENT AND THE LATEST ED17101V OF
THE WSDOT/APWA STANDARDS AND SPECIRCA17IONS, AS APPROVED AND MODIFIED BY THE CITY OF
RENTON /N 774E RENTON STANDARD PLANS & SPECIFICATIONS A SET OF APPROVED PLANS SHALL BE
KEPT ON SI7E AT ALL 77MES DURING CONSTRUCTION.
2. THE HOURS OF WnRK /N THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS
UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN
APPROVED TRAFFIC CONTROL PLAN MUST BE OBTAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC
RIGHT OF WAY.
J. ALL LOCATIONS OF EXIS77NG UTILITIES SHOWN ARE APPROXIMATE AND 1T SHALL BE 774E CONTRACTOR'S
RESPONSIBILI7Y TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE.
4. A PRE-CONS7RUC710N CONFERENCE AND A 24 HOUR N077CE SHALL BE REQUIRED PRIOR TO STAR77NG
NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY
PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE
OF THE CITY OF RENTON.) IT SHALL BE THE CON7RACTOR'S RESPONSIBILITY TO N077FY THE PUBLIC
WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR 774E MEANS, METHODS AND SEQUENCES OF CONSTRUCTION
AND FOR THE SAFETY OF KURKERS AND OTHERS ON 174E CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY 07HER
RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
ZPLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE
OVER ALL OTHER PLANS.
8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB 97E WHENEVER CONSTRUCTION IS IN
PROGRESS.
9. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT DRAWING OF THE SANITARY
SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR
LICENSED PROFESSIONAL SURVEYOR.
10. BACKFILL SHALL BE PLACED EQUALLY ON 807H SIDES OF THE PIPE 1N LAYERS WITH A LOOSE AVERAGE
DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT
OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE
OF THE PIPE OR TO THE SIDE OF 774E TRENCH. MATERIALS TO COMPLETE THE FILL OVER PIPE SHALL BE
THE SAME AS DESCRIBED.
11. OPEN CUT ROAD CROSSINGS FOR U77L/TY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE
BACKFILLED WI7H CRUSHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY
12. DATUM FOR WR77CAL CONTROL SHALL BE NORTH AMERICAN VER77CAL DATUM 1988 METERS, AND FOR
HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DA77JM 198311991 METERS UNLESS OTHERWISE
APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND
ELEVA77ONS ARE N07ED ON THE PLANS
13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE
SA77SFAC71ON OF THE DEPARTMENT FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COWPLE7101V
OF CONSTRUCTION.
14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN
ACCORDANCE WITH THE STANDARDS AND SPECIFICATIONS OF 774E CITY OF RENTON
PLANN/NG/BUILD/NGIPUBL1C WORKS DEPARTMENT AND THE LATEST ED171ON OF THE WSD0T/APWA
STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY 774E CITY OF RENTON /N 174E RENTON
STANDARD PLANS do SPECIFICATIONS. THIS SHALL INCLUDE NECESSARY LEVELING OF 774E 7RENC14 BOTTOM
OR THE TOP OF THE FOUNDA77ON MAT>=R/AL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED
BEDDING MATERIAL, TO UNIFORM GRADE SO THAT 774E ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED
ON A UNIFORMLY DENSE, UNYIELDING BASE. PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES ABOVE AND
BELOW THE PIPE.
15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SOR 35,
OR DUCTILE IRON CLASS 50, UNLESS 07HERWSE APPROVED BY THE WASTEWATER UTILITY.
16. IN UNIMPROVED AREAS MANHOLE TO EXTEND MINIMUM 6 INCHES AND MAXIMUM 12 INCHES ABOVE
FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAMETER CONCRETE RING POURED AT GRADE. IN PAVED
AREA, COVER MUST SLOPE IN ALL DIREC71ONS TO MATCH PAVING.
1. BACKWATER VALVE SHALL BE LOCATED WITHIN 5' OF THE FOUNDATION.
2. SEE SHEETS 3 AND 4 FOR 774E APPLICABLE LOTS.
J. WHERE DEPTH TO PIPE INVERT IS LESS THAN 3 FEET, SUBSTITUTE CONCRETE
ME7ER BOXES FOR VALVE CHAMBER. FOG777E NO. 2 (CONC. LID WITH ALUM.
INSPECTION PLATE). STACK 2 OR 3 BOXES AS NECESSARY.
4. WHERE DEPTH TO PIPE INVERT IS GREATER THAN 5 FEET, SUBSTITUTE 48" CONCRETE
MANHOLE PER CITY OF RENTON DWG NO. BR28.
FROM h
4" SIDE
COM
SWING CHECK VAL VE
MODEL 104P3 OR EQUAL
4" SIDE SEWER BA CKWA TER
VALVE A SSEMBL Y
NOT TO SCALE
345119
CITY OF RENTON
/r
Approved by. s � 41 Date:
Approved by: - Date:
Approved by: Date:
Approved by: Date:
®2012 TRIAD ASSOCIATES
-34 1
1�
TRLAD
ASSOCIATES
12112 115th Ave. NE
Kirkland, WA 98034-6923
425.821.8448
425.821.3481 fax
800.488.0756 toll free
www.triadassociates.net
(L CL
s
6 a
bb�b
i
z
M
0 a
aw1
M 0
0
z
RICHARD A. TaWK/NS PE
T MANAGER
MAt- a. HARRISON, PLS
PROJECT SURVEYOR
RICHARD A. MMK1NS PE
PROJECT ENGINEER
JEFFERY L COX, ASLA
PROJECT LANDSCAPE ARCHITECT
FIRST SUBMITTAL DATE: 7127107
SCALE: HOW.: NIA VIET.:N/A
PEER REVIEW: TOM MATT, PE 12/13/11
A.
-O� 4 25841
�Tt
& jONALR����
STAMP NOT VALID
UNLESS SIGNED AND DATED
JOB N0. 01- 04 7
SHEET N0. 9 OF 10