SANITARY SEWER NODES & SPECIFICATIONS
1. ALL WORK MA TER/ALS SHALL BE /N CONFORMANCE WITH THE STANDARDS AND
SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST
EDITION OF THE WSD T/APWA STANDARDS AND SPECIFICATIONS.
2. THE HOURS OF WORK /N THE STREET RIGHT -OF- WA Y SHALL BE LIMITED TO 8. 30
A. M. TO J. 30 P. M. ON WEEKDA YS UNLESS O THER WISE APPRO VED IN WRI TING B Y
THE DEPARTMENT OF PUBLIC WORKS AT 235-2620. ALL STREET CLOSURES,
PARTIAL, OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24
HOURS IN ADVANCE. THE POLICE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24
HOURS IN ADVANCE.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD SPECIFICATIONS
FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STATE
CHAPTER AMERICAN PUBLIC WORKS ASSOCIATION, LATEST EDITION (APWA) AND
CITY OF RENTON STANDARD SPECIFICATIONS.
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL
BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT
LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE.
5. A PRE -CONSTRUCTION CONFERENCE AND A 24 HOURS NOTICE SHALL BE REQUIRED
PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING
CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTA TI VE OF
THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILL ALL
CONSTRUCTION.
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE
CONSTRUCTION SITE.
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE
AND ANY RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS.
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER
CONSTRUCTION IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS -BUILT
DRAWING OF THE SANITARY SEWER SYSTEM WHICH HAS BEEN STAMPED AND
SIGNED BY A LICENSED PROFESSIONAL ENGINEER OF LICENSED
PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS
WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 81 INCHES,
THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE
COMPACTED LAYERS MUST EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS HOT MIX PATCH SHALL BE
PLACED WITHIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT
STANDARDS.
13. DATUM SHALL BE CITY OF RENTON, U.S.C. AND G. S.
14. ALL DISTURBED AREAS SHALL BE SEEDED MULCHED OR OTHERWISE STABILIZED TO
THE SA TI SFA C TION OF THE DEPARTMENT FOR THE PREVENTION OF ON- SI TE EROSION
AFTER THE COMPLETION OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED
FOUNDATION IN ACCORDANCE WITH SECTION 7- 02.3(1) OF THE CURRENT STATE OF
WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION.
THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF
THE FOUNDA TION MA TERIAL AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED
BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE
WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING
SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED
ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS 50.
17. IN UN -IMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCH AND MAXIMUM 18
INCH ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL
DIRECTIONS TO MATCH PAVING.
1/2'� -i
1/8" RAISE-1/2- WIDE
BORDER
10"
9„
8 3/4"
l 1l
CAST IRON RING AND COVER
1'
12"
3/4" SPACES SPACED-3/4" FIBER JO
AS INDICATED -HT 1/8" PACKING
PIPE MA TER/AL
AS SPECIFIED.
1/8
PROPERTY LINE
SIDE SEWER MAIN TO BUILDING SEWER
,jj_ : I- U I UKL
6 " SEWER PIPE ' 6. 0' BL D G SE WER
6" SIDE OUTLET TEE ? 2"X4" STUD SERVICE IMARKER
PAINT UPPER PORTION WHITE
w AND STENCIL ON SIDE WORD
"SE WER " WITH 3 " HIGH
BLACK LETTERS.
6" SIDE SEWER & BUILDING SEWER
PLAN
6" SIDE SEWER
1: J. 5 MIX \ NO TE:
CONCRETE 60' ALLOWABLE MAX SIDE SEWER SHALL HA VE A
BLOCKING FOR CAST OR MINIMUM 5' COVER AT PROPERTY
UCTILE IRON PIPE. LINE OR 3-5' LOWER THAN THE
6"MIN 4 MAX LOWEST HOUSE ELEVATION, WHICH-
25" MIN EVER IS LOWER.
6 "MIN HORIZONTAL
6" SIDE OUTLET TEE
SEWER MAIN
CONC. BLOCKING ANGLE
OF TEE A T MAIN OVER 25'
ELEVA TION
29 MIN SLOPE
TYPICAL SIDE SEWER
ELEVA TION
— 4 3/4"
PLUG TO BE SEALED IN SAME
MANNER AS MAIN SEWER JOINTS.
CLEAN -OUT DETAIL
EXISTING SEWER MAIN
f6" SIDE SEWER
f 6 "TEST TEE
TO BE INSTALLED
A T CONNECTION
NO TE:
MAKE TAP THROUGH CAST IRON
SADDLE SECURED TO SEWER MAIN
WITH STAINLESS STEEL BANDS
WHEN CONNECTING NEW SIDE
SEWERS TO EXISTING MAIN.
VITRIFIED CLAY, PLAIN &
REINFORCED CONCRETE, D 1 &
Cl PIPE SEWER MAINS ARE TO
BE CORE DRILLED.
SIDE SEWER SERVICE D E TA I L
TYP. SEE SH TS. 15 & 16
CASTING INLAND FDRY
)R EQUAL. P T#714
EE DETAIL 5.1.4
I DJUSTMEN T 4" MIN.
'ONE
fORTAR JOINTS
> TEPS-3/4" DEFORMED BAR
> TEPS SHALL BE INCLUDED
112"
NRETE RISER BY Ply INC.
APPROVED EQUAL
MAX. PIPE SIZE-21 " I.D.
LADDER -STD. ALUMINUM
OR GALVANIZED STEEL.
CONCRETE SHELF
PRECAST BASE SECTION
OR CAST IN PLACE
6" MIN.
I - -{ I `-- 6 MIN.
SANITARY MANHOLE TYPICAL DETAIL
(NTS)
TYP. SEE SH TS. 15 & 16
NOTES:
1, STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFTTY STEPS OR EQML
2, STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTI❑NS ARE INSTALLEI~
3, CASTING TO BE ❑LYMPIC FOUNDRY MH30 WITH MH30 D/T OR EQUAL, PER DWG, BR29
4, MANHOLE SECTIONS TO BE OF REINF❑RCED PRECAST CONCRETE
5, ❑PENING SHOULD BE ON DOWNSTREAM SIDE,
6, ALL JOINTS SHALL BE GROUTED,
7, SANITARY SEWER MANHOLES SHALL HAVE ALL INTERI❑R
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH S❑LIDS URETHANE COATING;
WASSER MC-CONSEAL OR APPROVED EQUAL;
COLOR OF C❑ATING SHALL BE WHITE.
oRH.
WA.5, �lr
1
`SIGNAL
"AS -BUILT" NOTE:
"AS -BUILT" IS BASED ON A ACTUAL FIELD SURVEY
BY TOUMA ENGINEERS AND INFORMATION SUPPLIED
BY CONTRACTOR.
RECOMMENDED
FOR APPROVAL
BY DATE
BY DATE
BY DATE
BY DATE 871-005-071