Loading...
HomeMy WebLinkAboutWTR2703471.10 N C:) F_ W X Ld J z U Q Lij 0�z n O F_ z LLi rr FRI LEGEND PROPOSED GATE VALVE — TEE (FL) ADAPTER (FL X MJ) a CONCRETE BLOCKING BEND (MJ) W/BLOCKING 0 SLEEVE (MJ) OR FLEX COUPLING PROPOSED WATER MAIN W EXISTING WATER MAIN r►. PROPOSED FIRE HYDRANT ASSY. EXISTING FIRE HYDRANT ASSY. -� EXISTING WATER METER —SS SS-- SEWER MAIN ASPHALT RESTORATION ' MATCH EXISTING SECTION O EXISTING MANHOLE CATCH BASIN _CT ST- EXISTING STORM 16'X16'X8' WET TAPPING TEE (MJXFL) 8' TAPPING GATE VALVE (FLXMJ) !N L CONNECTION BY CITY FORCES STAi 11+85.07 a SAW CUT 4' TRENCH REPLACE ASPHALT AND PAVEMENT MATCH EXISTING PAVEMENT SECTION (26' TEST TEE WITH PLUG FACE UP (TYP,) 24 PVC SIDE SEWER RUBER GASKETED, ASTM 3034 c+ @ 13.20% 16, F 4 24 PVC SIDE SEWER RUBER GASKETED, ASTM 3034 @ 16327 5� 6' SURFACE CLEANOUT WYE (TYPJ I ® 4' DI SAW CUT 4' TRENCH REPLACE ASPHALT AND PAVEMENT MATCH EXISTING PAVEMENT SECTION NOTE: BOUNDARY AND TOPOGRAPHY ARE BASED ON MAPPING PROVIDED TO E3RA BY GEODATUM SS AND OBSERVATIONS MADE IN THE FIELD. THE INFORMATION SHOWN DOES NOT CONSTITUTE A FIELD SURVEY BY E3RA. ALL DETAILS CAN BE FOUND ON CITY OF RENTON WEBSITE STANDARD DETAILS, SEE SHEETS 4 AND 5 FOR NOTES. SEE SHEETS 9 AND 10 FOR DETAILS THIS PLAN SUPERSEDES ALL PREVIOUS PLANS ALL UTILITY SHALL BE POTHOLED AND VERIFIED BY CONTRACTOR PRIOR TO BEGINNING CONSTRUCTION. SHOULD CONFLICTS EXIST THE ENGINEER IS TO BE NOTIFIED IMMEDIATELY. Call 2 Working Days Before You Dig 1-800-424-5555 Utilities Underground Location Center � w o 0 135.2' F1+80 I I i �25.6' STA: 1 14 +70 I wl ' ' r I ao h EAASS DISK W/PUNCH IN 3"x3" CONC z POST IN ASE y -1+60 i i STA: 11+20 A D4 ' N❑RTHING: 53756.917 I EASTING: 395980,70 1 STA: 10+00 316.07' BEARING) FOUND 1 1/2" BRASS DISK S. 6th STREET W/PUNCH IN 3"x3" CONC POST IN CASE (C.O.R. PT #1898) NORTHING: 53756.917 i +20 EASTING: 395983.750 j 0+10 i EXISTING FIRE HYDRANT 0+00 FIRE HYDRANT Q Jiur_ JLWr_m IE: 23,50 (APPROXIMATE) MAINTAIN MIN 2' COVER EXISTING SSMH RW=25.93 IE=17.79 8" N iE=17.79 8" S 10 0 10 20 SCALE IN FEET 66 ok ro- Vowca�tr' st►v��s. f� 3 � I I SSMH RIM=27.91 I__IE=23.40 8" S i 6' CI SADDLE I �— IE 20.49 i s 1-8' VERTICAL CROSS (FOR POLYPIGGING) i 2-8' BLIND FLANGE W/2' TAP AND 3 o, 2' PLUG d' 1-8' PLUG (MJ) r` 2' PERMANENT BLOW —OFF ASSEMBLY I SEE DETAIL B114 AND B105 SHEETS SHEET 10 > STAt 13+25.07R �-- NORTHINGj 53842.59 m EASTINGs 396024.66 i NOTE: SEE SHEET S-1 SURVEY BY GE❑DATUM INC. FOR VERTICAL AND H❑RI70NTAL C❑NTR❑LS, ALL TRENCH REST❑RATI❑N SHALL BE PER THE CURRENT CITY OF RENT❑N TRENCH REST❑RATI❑N AND STREET OVERLAY DETAIL, SW 1/4, SE 1/4, SEC 18, TWN 23N, RGE 5E, W,M, 530 SHATTUCK AVE S RENT❑N, WA 98057 - _ CHECKED FOR COMPLIANCE TO CITY STANDARDS r Date Iyw�' 'Al Date 9 08 DateglslQ.? p J� PROJECT: Renton Triplexes No, Date Revision BY RA Inc. 5 E. Bh'1 Renton WA 1 5/5/08 RESPONSE TO CITY COMMENTS CRL gg02 29th Ave. W. _ ��``$og CIA S���TITL :Water, Side Sewer, and \' _- 5 Q� 2 6/15/08 RESPONSE TO CITY COM' ,AFNITQ CRL Suite B102 Fire Plan Everett, WA 982041. 3 7/17/08 RESPONSE FIRE COMMENTS CRL - �tr 425-356-3372 ,� f '�o ,� � � DESIGNER: CRL JOB NO: T07250 IST 4 8/7/08 RESPONSE CITY COMMENTS CRL 425-356-3374 f11 <'{ ass ONAG�Q_ Q `; BY: CRL SCALE: 1 "' = 10' WWW.e3ra.com CHECKED BY: RCE SHEET- 4 EXPIRES 0, 3 }Q DATE- 6/15/08 FILE: phrent.d j- b " 0 - '_s� (00,'s-34?fCG,�