Loading...
HomeMy WebLinkAboutWWP2703473.16a E) I 0 0 00 0 i 0 o' i 1' i 0 v 0 z 0 0 0 ry n i 0 Ln 00 co Ln N 00 z w 0 i 0 0 C6 0 0 0 i 0 0 i w Q z w w CD 0 0 N z 0 y go U C w 7 N 0 N r O Q CD z 0 D_ MISCELLANEOUS ABBREVIATIONS: AD AGITATOR DRIVE BFP BELT FILTER PRESS B BLOWER CV CONTROL VAVLE FV AUTOMATIC VALVE GR GRIT DEWATERING SCREW SA SAMPLER SC SCREW CONVEYOR SCN FINE SCREEN SLG/SG SLIDE GATE WG WEIR GATE NOTES: 1. THIS IS A GENERALIZED LEGEND SHEET. THIS CONTRACT MAY NOT USE ALL INFORMATION SHOWN. 2. INFORMATION SHOWN MAY NOT BE ALL INCLUSIVE. SEE ALSO ISA S5.1, S5.3 AND S7.3. 3. INSTRUMENTS MARKED WITH AN ASTERISK ARE FURNISHED WITH THE EQUIPMENT. 4. REFER TO ISA RP7.7 FOR INSTRUMENT AIR QUALITY STANDARDS. INSTRUMENT SYMBOL IDENTIFIERS J-3 J-4, J-5 J-1: IDENTIFICATION LETTERS (SEE TABLE BELOW) J-4: FUNCTION BLOCK (SEE TABLE BELOW) pi-6 J-2: LOOP NUMBER J-5: PANEL NUMBER J-3: VENDOR DESIGNATOR (NOTE 3) J-6: HANDSWITCH DESIGNATOR (SEE BELOW) FIRST LETTER SUCCEEDING LETTERS MEASURED OR INITIATING VARIABLE MODIFIER READOUT OR PASSIVE FUNCTION OUTPUT FUNCTION MODIFIER A ANALYSIS ALARM B BURNER, COMBUSTION USER'S CHOICE USER'S CHOICE USER'S CHOICE C USER'S CHOICE CONTROL CLOSED D DENSITY DIFFERENTIAL DAMPER E VOLTAGE SENSOR (PRIMARY ELEMENT) F FLOW RATE RATIO (FRACTION) G USER'S CHOICE GLASS, VIEWING DEVICE H HAND HIGH I CURRENT (ELECTRICAL) INDICATE J POWER SCAN K TIME, TIME SCHEDULE TIME RATE OF CHANGE CONTROL STATION L LEVEL LIGHT LOW M MOISTURE MOMENTARY MIDDLE, INTERMEDIATE N USER'S CHOICE USER'S CHOICE USER'S CHOICE USER'S CHOICE 0 USER'S CHOICE ORIFICE, RESTRICTION OPEN P PRESSURE, VACUUM POINT (TEST) CONNECTION Q QUANTITY INTEGRATE, TOTALIZE R RADIATION RECORD S SPEED, FREQUENCY SAFETY SWITCH T TEMPERATURE TRANSMIT U MULTI VARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION V VIBRATION, MECHANICAL ANALYSIS VALVE, DAMPER, OR LOUVER W WEIGHT, FORCE WELL X UNCLASSIFIED X AXIS UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED Y EVENT, STATE, PRESENCE Y AXIS RELAY, COMPUTE, CONVERT Z POSITION, DIMENSION Z AXIS DRIVER, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT GENERAL INSTRUMENT OR FIELD MOUNTED PRIMARY LOCATION ACCESSIBLE AUXILIARY LOCATION ACCESSIBLE NORMALLY INACCESSIBLE OR FUNCTION SYMBOLS TO OPERATOR TO OPERATOR BEHIND THE PANEL DISCRETE INSTRUMENTS 0 _ SHARED DISPLAY, SHARED CONTROL COMPUTER FUNCTION PROGRAMMABLE LOGIC CONTROL _ J-4 FUNCTION BLOCK DESIGNATORS Fil SUMMING LJ n� ROOT EXTRACTION 7 DIFFERENCE SQUARE ROOT ❑f INTEGRAL xn EXPONENTIAL %t DERIVATIVE F>1 HIGH SELECTING �X MULTIPLYING © LOW SELECTING DIVIDING F BIAS *�* CONVERT: F(X) NONLINEAR OR UNSPECIFIED FUNCTION * E - VOLTAGE H - HYDRAULIC I - CURRENT 0 - ELECTROMAGNETIC, SONIC P - PNEUMATIC R - RESISTANCE (ELECT) A - ANALOG D - DIGITAL B - BINARY J-6 HANDSWITCH DESIGNATORS HOA HAND -OFF -AUTO LR LOCAL -REMOTE HOR HAND -OFF -REMOTE OC OPEN -CLOSE F-R FORWARD -REVERSE OCA OPEN -CLOSE -AUTO 1-0 ON -OFF INSTRUMENT SERVICES AS>- INSTRUMENT AIR SUPPLY (NOTE 4) >_ 120 VAC ELECTRICAL SERVICE (DIFFERENT VOLTAGES ARE SPECIFICALLY NOTED) PLC INPUT/OUTPUT DISCRETE INPUT I ANALOG INPUT I 41 DISCRETE OUTPUT ♦ ANALOG OUTPUT FLOW PRIMARY ELEMENTS ORIFICE PLATE �1 SINGLE PORT PITOT TUBE OR PITOT-VENTURI TUBE VENTURI TUBE AVERAGING PITOT TUBE FLUME WEIR TURBINE OR PROPELLER -TYPE PRIMARY ELEMENT ROTAMETER ROTAMETER WITH INTEGRAL VALVE THERMAL MASS FLOWMETER POSITIVE DISPLACEMENT TYPE FLOW TOTALIZING INDICATOR D VORTEX SENSOR TARGET TYPE SENSOR FLOW NOZZLE M MAGNETIC FLOWMETER SONIC FLOWMETER LINES MAIN PROCESS SECONDARY PROCESS 12/13 REFERENCES TO OTHER SHEET LINE CONTINUATION DRAWING REFERENCE 24" BW PIPE SYSTEM PIPE SIZE IN INCHES - PNEUMATIC - ELECTRICAL MECHANICAL ELECTRICAL OR CONNECTED - + - I NOT CONNECTED -I I NOT CONNECTED VALVES GATE VALVE GLOBE VALVE PLUG VALVE CHECK VALVE PINCH VALVE DIAPHRAGM VALVE BUTTERFLY VALVE ICI BALL VALVE NEEDLE VALVE PLUG (COCK) PRESSURE REDUCING REGULATING VALVE, SELF-CONTAINED BACK PRESSURE REGULATING VALVE, SELF-CONTAINED PRESSURE REDUCING REGULATOR WITH EXTERNAL PRESSURE TAP 3-WAY VALVE ® 4-WAY VALVE ANGLE VALVE PRESSURE RELIEF VALVE * FC = FAIL CLOSED LC = LOCKED CLOSED FO = FAIL OPEN LO = LOCKED OPEN CLOSED DURING NORMAL OPERATION SHADING INDICATES PORT TO BE CLOSED DURING NORMAL OPERATION. DOT INDICATES PORT TO BE CLOSED DURING ALTERNATE OPERATION. VALVE OPERATORS DIAPHRAGM —� CYLINDER OPERATOR DIAPHRAGM PRESSURE BALANCED SOLENOID HAND SV SOLENOID VALVE O MOTOR CV-103 CONTROL VALVE TAG TYPICAL CONNECTION DIRECT CONNECTION TO PROCESS TEMPERATURE ELEMENT WITH WELL —0— IN -LINE DEVICE 0 RADIATION OR SONIC SENSING FILLED SYSTEM, DIAPHRAGM SEAL CONNECTION S=347340 EQUIPMENT zoCENTRIFUGAL PUMP _� SUBMERSIBLE PUMP OBLOWER ECHEMICAL PUMP INJECTOR DOUBLE DIAGRAM AIR DRIVEN PUMP ROTARY LOBE PUMP OSAMPLER O I 3 M MIXER CDCD TURBINE PUMP n n PROGRESSIVE CAVITY PUMP LINE 1 LINE 2 LINE 3 EQUIPMENT EQUIP # TAG MISCELLANEOUS FLANGE UNION Y STRAINER FLOW STRAIGHTENING VANE TEE SCREWED CAP WELDED CAP BLIND FLANGE REDUCER HOSE BIBB CONNECTION DIAPHRAGM SEAL RUPTURE DISK, PRESSURE RUPTURE DISK, VACUUM PURGE U THERMOMETER WELL INTERLOCK. NUMBER IS THE CROSS REFERENCE TO A SPECIFIC ELEMENTARY DIAGRAM OR TO A SPECIFIC CONTROL STRATEGY DESCRIBED IN THE SPECS EXPANSION JOINT FLEXIBLE COUPLING FLEXIBLE HOSE CONNECTION SLUICE GATE OR SLIDE GATE 'k AV - AIR VALVE F - FILTER WATER T - TRAP FH - FIRE HYDRANT RECORD DRAWING These Record Drawings have been prepared based on information provided by the contractor and others. Kennedy/Jenks Consultants has not verified the accuracy or completeness of information provided to them and does not warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. Kennedy/Jenks Consultants STONEGATE SURVEYED: SCALE: DATE: VERTICAL NAVD 1988 DESIGNED: -- HORIZONTAL: NAD 1983/1991 CITY 0 E 06-1 1-2010 32001 32nd Avenue South, Suite 100 PAR .� RENT 0 N LIFT STATION REPLACEMENT PAGE:ROT Fliri I K: Federal Way, WA 98001 DRAWN. LMM DRAWING N0: ONE INCH DATU M Ph. 253-835-6400 AT FULL SCALE Planning/Building/Public Works Dept. PROCESS AND INSTRUMENTATION DIAGRAM Roth Hill, LLC Tel 425.869.9448 www.rothhill.com � RECORD DRAWING RFB 20 1ffAP CHECKED: NE INCH 11130 NE 33rd Place Suite 200 Bellevue, WA 98004 Fax 253-952-3435 PAR SCALEIF ACOCORDNGLY N0. REVISION BY DATE APPROVED: LEGEND SHEET: OF: 40 42