Loading...
HomeMy WebLinkAboutWWP2703473.38N U i U) i i 0 c� i cn CD z O 0 0 cn CD Ln 00 C_ 0 s= 0 6 Cn i N 00 N z cD 0 i 0 0 w 0 0 1-1 0 0 LL Lv 75 z w L� CD N 0 s LC > T A C1 CONTROL BUILDING SEE SHT. Al ASPHALT—` PAVEMENT SEE SHT. C7 0 HOT BOX W/ BACKFLOW PREVENTER & YARD HYDRANT 8" VAULT VENT GENERATOR SET o0 • F----------------------------------------------------------------------------------� I I 8" VAULT `IF` VENT W/ \ ST\/ON �OLLARDS �S�_ Eqq �E� r ----- ------------------------------------ • I I 7"MIN.(TYP.)_j —� 1_T— I_ - DOORS OPEN IL WIDE / I I 5'-5" L --- __-I LADDER I I I I - I 3'x5' FRP LANDING' 7 BELOW VAULT I CEILING PER I I STRUCT. DWGS. I I I I \ I I I 48"x72" ACCESS HATCH, \ I LW PRODUCTS HD-3C \ I I� I I I I A I I I 48"x72" ACCESS HATCH, C13 LW PRODUCTS HD-3C I I \ I I 1 3'x5' FRP LANDING- 7' BELOW VAULT I I I 1'x1' CONCRETE FILLET W/ CEILING PER I j 4-#4 DEFORMED REINF. STRUCT. DWGS. I- ---� j I REBAR (TYP. OF 4) I DOORS OPEN I / 18" WIDE �\ I LADDER OOP -- T------- ---- I --------------------� r-----------------1— I I I L— — — — — — — —— — — — — — — — — — — — — — — — — — — — — -----------------------------—------j 12" ROMAC STYLE 501 FLEX CPLG. UNI—HOIST CORE MOUNTED / SLEEVE PER SPECS. OVERFLOW STORAGE VAULT (TYP. OF 4) COORDINATE SEE SECTIONS, SHT. C13 LOCATIONS WITH OWNER. I X / I I I wI ZI J Q I U 0 I- I MI C :14 I CHAIN LINK SECURITY FENCE \ SEE SHT. C7 WET WELL SEE \ DETAILS, SHTS. \ C13 AND C14 / \ 12"PVC C900 5 BEND • \ SEWER BYPASS (MJxMJ) \SEE SHT. C5 8" WET WELL \STD VENT \S�TF \F " AERIAL LIGHT MOUNTED ON POLE \ (SEE ELECTRICAL DWG.) 12" GATE VALVE— (M JxM J) GRAVITY SEWER - MANHOLE SEE I i1►1T��, �� II �I�I�iI I■ hIII l"ill^�'r I I E I VALVE VAULT SEE I (; DETAILS, SHT. C15 12" ROMAC STYLE 501 FLEX CPLG. x x x x x x \ 12"PVC GRAVITY SEWER SEE SHT. C5 SHT. C5 / f i gSFMF�r / `- 8"PVC C900 FORCE MAIN SEE SHT. C5 I TRANSFORMER I BOLLARDS y / ° 4 / 4 4 ° L 4 4 a a ° 4 4 ° 4 d 4 4 ° 4 n 48" 36" 24" 12" 0 2' 4' 6' 8' SCALE IN INCHES / FEET _ m _ dL a a a — S ROTI-'rl I LL Roth Hill, LLC Tel 425.869.9448 www.rothhill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 BRO10 w41� °'V wasI�lI �r 37847 ��GISTEg����� SIONAL E�� D STD_ was�I���� 45274 �EGISTF, �SSIONAL NO. I REVISION SURVEYED: MJL DESIGNED: ELB/LDS DRAWN: CHECKED: BY DATE APPR APPROVED: SCALE: AS NOTED ONE IN AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM e CITY OF RENTON Planning/Building/Public Works Dept. 1� BR0�9 41;10 1-6 4 r 37847 ��GISTEg�� �SSIONAL FOR CONSTRUCTION RECORDS ONLY REVISED TO INDICATE CONSTRUCTION RECORDS REVISED BY: TERRY VAN WECHEL DATE: JULY 20, 2012 CONTRACTOR: SHORELINE CONSTRUCTION THESE CONSTRUCTION RECORD DOCUMENTS HAVE BEEN PREPARED BY ROTH HILL, LLC. MOST FIELD INFORMATION PROVIDED BY OTHERS. ROTH HILL HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF INFORMATION PROVIDED BY OTHERS AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS. NOTES: 1. ALL DUCTILE IRON PIPING AND FITTINGS SHALL BE CEMENT LINED CLASS 52 EXCEPT FOR FLANGED SPOOLS (CL. 53) OR WHERE OTHERWISE NOTED ON DRAWINGS. ALL DI PIPING AND FITTINGS WITHIN WET WELL SHALL HAVE EPDXY COATED EXTERIOR PER SPECIFICATIONS. 2. BACKFILL AROUND STRUCTURES AND WITHIN 5' OF STRUCTURES SHALL BE SELECT MATERIAL COMPACTED TO 95% PER ASTM D1557. 3. ALL CONCRETE SUPPORTS TO BE FORMED. 4. ALL PIPE PENETRATIONS IN WET WELL, OVERFLOW STORAGE VAULT, AND VALVE VAULT SHALL USE LINK SEALS UNLESS OTHERWISE APPROVED. KOR—N—SEAL BOOTS SHALL BE USED FOR PIPE PENETRATIONS IN MANHOLES. ALL PENETRATIONS SHALL BE MADE WATERTIGHT. 5. ALL MECHANICAL JOINT FITTINGS SHALL BE RESTRAINED w/MEGALUGS. 6. WET WELL, OVERFLOW FACILITY & VALVE VAULT SHALL BE COATED INTERNALLY AND EXTERNALLY PER SPECIFICATIONS. 7. CORE DRILL ELECTRICAL & TELEMETRY PENETRATIONS IN FIELD AS REQUIRED. 8. FOR EACH HATCH, PROVIDE ROLL —OUT SAFETY NET PER SPECS. PROVIDE SS SAFETY CHAIN AT EACH OPEN END OF HATCHES. STONEGATE LIFT STATION REPLACEMENT WET WELL AND OVERFLOW FACILITY PLAN DATE: 6/25/2010 FIELDBOOK: PAGE: