Loading...
HomeMy WebLinkAboutWWP2703473.46i 0 0 00 0 0 Y / 0 0 z 0 v a 0 / U) 0 / Ln 00 0 _o 6 / LO N 00 z 0 LJ 0 / 0 O 0 0 0 / 0 0 / w c z w co 0 0 N z 0 r w M 6 Lj HVAC/PLUMBING LEGEND 24x12 =24xi2 DUCT — FIRST FIGURE IS SIDE SHOWN 12x12 12x12 ------------------------ DUCT WITH ACOUSTICAL LINING DIMENSIONS ARE NET FREE AREA DIRECTION OF FLOW INCLINED RISE (R) OR DROP (D), ARROW IN DIRECTION OF AIR FLOW SUPPLY DUCT — ELBOW UP OR DOWN STANDARD BRANCH WITH SPLITTER DAMPER RETURN DUCT — ELBOW UP OR DOWN VD VD= MANUAL VOLUME DAMPER - STANDARD BRANCH WITH SPLITTER DAMPER AND TURNING VANES BD gD BACK DRAFT DAMPER FD FD FIRE DAMPER (PROVIDE ACCESS DOOR FOR INSPECTION AND LINK REPLACEMENT.) c T c - EDn ED GRILLE AND REGISTER CONNECTION WITH EXTRACTION DAMPER CD CONTROL DAMPER AD r___,Ap AD AD!---' DUCT ACCESS DOOR FC FC FLEXIBLE DUCT CONNECTION ��12 1?0 1 .x 00 CSD CSD CEILING SUPPLY DIFFUSER INDICATING NECK SIZE, THROW, & AIR QUANTITY X SUPPLY DUCT IN SECTION z EXHAUST OR RETURN DUCT IN SECTION 12x1 200 CER I ; 1� 200 CER CEILING EXHAUST OR RETURN REGISTER INDICATING NECK SIZE, THROW, & AIR QUANTITY OT THERMOSTAT �12xl �0„`' WSD (�1� �l �00 WSD WALL SUPPLY DIFFUSER INDICATING NECK SIZE, THROW, & AIR QUANTITY TS TEMPERATURE SENSOR 12x120�12x1 200 WER WER WALL EXHAUST OR RETURN REGISTER INDICATING NECK SIZE, THROW, &AIR QUANTITY HS HAND SWITCH M❑ FLOW METER TURNING DUCT WH WATER HEATER HB HOSE BIBB OI INTERLOCK GATE VALVE OM MOTOR IOI BALL VALVE HVAC AND PLUMBING ABBREVIATIONS FAN SCHEDULE TAG NO. LOCATION AREA SERVED TYPE DRIVE RPM CFM ESP (IN. W.C.) HP VOLTS/PHASE NOTES EF-1 CONTROL BUILDING CONTROL SIDEWALL DIRECT 1550 650 0.25 1/8 120/1 1,2,3 BUILDING EXHAUST NOTES: 1. PROVIDE BACK DRAFT DAMPER. 2. ALL ONE —PHASE FRACTIONAL HP MOTORS TO BE FURNISHED WITH FACTORY —MOUNTED DISCONNECT SWITCHES. 3. THERMOSTAT —CONTROLLED. ELECTRIC HEATER SCHEDULE TAG NO. LOCATION AREA SERVED TYPE AIRFLOW kW VOLTS/ NOTES (CFM) PHASE EH-1 CONTROL BUILDING CONTROL BUILDING UNIT 700 2 208/1 1 NOTES: 1. REMOTE THERMOSTAT CONTROLLED. CONTROL DAMPER SCHEDULE LOUVER INTAKE/ AIRFLOW WIDTH HEIGHT VOLTS/ TAG NO. LOCATION SERVED EXHAUST (CFM) (IN) (IN) PHASE CD-1 CONTROL BUILDING L-1 INTAKE 650 24 24 120/1 LOUVER SCHEDULE TAG NO. LOCATION AREA SERVED INTAKE/ EXHAUST AIRFLOW (CFM) WIDTH (IN) HEIGHT (IN) TYPE L-1 CONTROL BUILDING CONTROL BUILDING INTAKE 650 24 24 6" ACOUSTIC L-2 CONTROL BUILDING CONTROL BUILDING EXHAUST 650 24 24 6" ACOUSTIC NOTES: 1. SEE SECTION 10.10200 FOR ADDITIONAL REQUIREMENTS. 650 CFM L-2 BACKFLOW PREVENTER SCHEDULE SIZE PRESSURE TAG NO. LOCATION TYPE (INCHES) RATING NOTES (PSI) RPBA CONTROL REDUCED 1 175 1 BUILDING PRESSURE NOTES: 1. SEE SECTION 10.15400 FOR ADDITIONAL REQUIREMENTS. AC AIR CONDITIONING F FAN NC NORMALLY CLOSED I I \IJ AH AIR HANDLING UNIT FC FAN COIL NO NORMALLY OPEN SP=60 F FD FLOOR DRAIN BD BELT DRIVE OSA OUTSIDE AIR BFP BACKFLOW PREVENTER GPM GALLONS PER MINUTE P PUMP BR BOILER I CONTROL BUILDING CONTROL BUILDING BTU BRITISH THERMAL UNIT H HEATING PD PRESSURE DROP HC HEATING COIL PROP PROPELLER I CC COOLING COIL HOA HAND/OFF/AUTO PW POTABLE WATER CD CONTORL DAMPER HP HORSEPOWER RF RETURN FAN CENT CENTRIFUGAL HS HAND SWITCH RPBA REDUCED PRESSURE BACKFLOW ASSEMBLY CER CEILING EXHAUST RETURN HSPF HEATING SEASONAL PROFICIENCY FACTOR RPM REVOLUTIONS PER MINUTE CFM CUBIC FEET PER MINUTE HTG HEATING CH CHILLER HVAC HEATING VENTILATING AIR CONDITIONING SEER L -------------- CHWS CHILLED WATER SUPPLY HWR HEATING WATER RETURN SP STATIC PRESSURE/SET POINT CHWR CHILLED WATER RETURN HWS HEATING WATER SUPPLY SQ. FT. SQUARE FEET CO CLEAN OUT CSD CEILING SUPPLY DIFFUSER IN. INCHES V VENTILATING CV COEFFICIENT, VALVE FLOW VD VOLUME DAMPER L LOUVER VTR VENT —TO —ROOF r-- I ------------- D DRAIN LAV LAVATORY VVT VARIABLE VOLUME/TEMPERATURE DB DRY BULB LBS POUNDS I / � DH LOSS IN FEET LWT LEAVING WATER TEMPERATURE WB WET BULB I I EER ENERGY EFFICIENCY RATIO MBH BTU PER HOUR (THOUSANDS) WC WATER CLOSET I 1 EF EXHAUST FAN MFGR. MANUFACTURER WER WALL EXHAUST OR RETURN ESP EXTERNAL STATIC PRESSURE WG WATER GAUGE I EWT ENTERING WATER TEMPERATURE WH WATER HEATER I WSD WALL SUPPLY DIFFUSER i NOTES: 1. ELECTRICAL INSTALLATION BY THE ELECTRICAL CONTRACTOR IS LIMITED TO THE CONDUIT AND WIRE NECESSARY TO PROVIDE POWER TO THE UNITS. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY CONDUIT, WIRING, CONTROLS AND APPURTENANCES FOR A COMPLETE AND OPERABLE HVAC SYSTEM. 2. ALL SPACE CONDITIONING EQUIPMENT SHALL MEET THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE AND SECTION 10.15800. 3. PROVIDE PLUMBING AND DRAIN PIPING IN ACCORDANCE WITH SECTION 10.15400. PROVIDE SERVICE CONNECTION AND METER IN ACCORDANCE WITH KING COUNTY WATER DISTRICT NO. 90 STANDARD DETAILS. SEE CIVIL DRAWINGS FOR LOCATION. ROTFIHI LL Roth Hill, LLC Tel 425.869.9448 www.rothhill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 Kennedy/Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, WA 98001 Ph. 253-835-6400 Fax 253-952-3435 HVAC SCHEMATIC SURVEYED: I SCALE: DESIGNED: DBT DRAWN: JW t RECORD DRAWING RFB 20 12 JMF CHECKED: ONE INCH RPR AT FULL SCALE IF NOT ONE INCH N 0. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY 1 I - - I 650 CFM VERTICAL: NAVD 1988 HORIZONTAL- NAD 1983/1991 DATU M S=347320 CITY OF RENTON Planning/Building/Public Works Dept HOT BOX PLUMBING SCHEMATIC RECORD DRAWING These Record Drawings have been prepared based on information provided by the contractor and others. Kennedy/Jenks Consultants has not verified the accuracy or completeness of information provided to them and does not warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. STONEGATE LIFT STATION REPLACEMENT HVAC AND PLUMBING SCHEMATICS AND EQUIPMENT SCHEDULES M �0 �42 09 `SS'IONAL DATE: 06-11-2010 PAGE: DRAWING NO: M1 art r S , -3 (+ -) -3 ao 20 42