Loading...
HomeMy WebLinkAboutWWP2703473.50 0 N z 0 ry LL, T ABBREVIATIONS a CIRCUIT BREAKER AUX. CONTACT, FLEX FLEXIBLE NTS NOT TO SCALE CLOSED WHEN BREAKER IS CLOSED FLUOR FLUORESCENT OH OVERHEAD A AMMETER, AMPERES FREQ FREQUENCY OT OVER TEMPERATURE AC ALTERNATING CURRENT FT FEET, FOOT OL THERMAL OVERLOAD RELAY A/D ANALOG TO DIGITAL FU FUSE PA PUBLIC ADDRESS ADJ ADJUSTABLE (F) FUTURE PB PULLBOX AF AMPERE FRAME FVNR FULL VOLTAGE NON REVERSING PE PHOTOELECTRIC AFD ADJUSTABLE FREQUENCY DRIVE FVR FULL VOLTAGE REVERSING PEC PHOTOELECTRIC CELL AFF ABOVE FINISHED FLOOR FWD FORWARD PF POWER FACTOR AFG ABOVE FINISHED GRADE GA GAUGE PFR POWER FAIL RELAY AIC AMPERES INTERRUPTING CAPACITY GALV GALVANIZED PH PHASE AL ALUMINUM GEN GENERATOR PLC PROGRAMMABLE LOGIC CONTROLLER ALT ALTERNATOR GFI GROUND FAULT INTERRUPTER A/M AUTO/MANUAL CONTROLLER G, GND GROUND PNL PANEL ANN ANNUNCIATOR GRS GALVANIZED RIGID STEEL PNLBD PANELBOARD APPROX APPROXIMATE H2O2 HYDROGEN PEROXIDE PRI PRIMARY AS AMMETER SWITCH HH HANDHOLE PS PRESSURE SWITCH AT AMMETER TRIP HMI HUMAN MACHINE INTERFACE PSI POUNDS PER SQUARE INCH ATS AUTOMATIC TRANSFER SWITCH HOA HAND -OFF -AUTOMATIC PVC POLYVINYL CHLORIDE AUTO AUTOMATIC HOR HAND -OFF -REMOTE PWR POWER AUX AUXILIARY HORIZ HORIZONTAL (RL) RELOCATE AWG AMERICAN WIRE GAGE HP HORSEPOWER (RLD) RELOCATED b CIRCUIT BREAKER AUX. CONTACT, HPS HIGH PRESSURE SODIUM RCPT RECEPTACLE CLOSED WHEN BREAKER IS OPEN HTR HEATER RCT REPEAT CYCLE TIMER BCG BARE COPPER GROUND HV HIGH VOLTAGE REQD REQUIRED BLDG BUILDING HZ HERTZ (CYCLES PER SECOND) RM ROOM C CONDUIT, CONTACTOR IND LT INDICATING LIGHT RPM REVOLUTIONS PER MINUTE CAB CABINET INCAND INCANDESCENT RT RESET TIMER CAP CAPACITOR INSTR INSTRUMENT, INSTRUMENTATION SCR SILICON CONTROLLED RECTIFIER CB CIRCUIT BREAKER 1/0 INPUT/OUTPUT SD SMOKE DETECTOR CC CONTROL CABLE, CLOSING COIL JB JUNCTION BOX SEC SECONDS, SECONDARY CHH COMMUNICATION HANDHOLE KA KILOAMPERES SECT SECTION CKT CIRCUIT KCMIL THOUSANDS OF CIRCULAR MILS SF SUPPLY FAN/STATIC FILTER CMH COMMUNICATION MANHOLE KV KILOVOLTS SHH SIGNAL HANDHOLE CO CONDUIT ONLY KVA KILOVOLT AMPERES SHT SHEET COMM COMMUNICATION KVAR KILOVOLT AMPERES REACTIVE SIG SIGNAL COND CONDUCTOR KVARH KILOVOLT AMPERES REACTIVE SN SOLID NEUTRAL CONT CONTINUED, CONTINUATION HOURS SPECS SPECIFICATIONS CPT CONTROL POWER TRANSFORMER KW KILOWATTS SPD SURGE PROTECTIVE DEVICE CID CONTROL PANEL KWH KILOWATT HOURS SPDT SINGLE POLE DOUBLE THROW CR CONTROL RELAY LP LIGHTING PANEL SS STAINLESS STEEL CS CONTROL SWITCH LPS LOW PRESSURE SODIUM SSS SOLID STATE STARTER CT CURRENT TRANSFORMER LTG LIGHTING SW SWITCH CWP COLD WATER PIPE LTS LIGHTS SWBD SWITCHBOARD DC DIRECT CURRENT (M) MODIFIED SWGR SWITCHGEAR DIA DIAMETER mA MILLIAMPERES SYNC SYNCHRONIZING DIAG DIAGRAM MAX MAXIMUM TB TERMINAL BOX, TERMINAL BOARD DISC DISCONNECT MCC MOTOR CONTROL CENTER TC TELEPHONE CABINET DISTR DISTRIBUTION MCP MOTOR CIRCUIT PROTECTOR TEL TELEPHONE DN DOWN MFR MANUFACTURER TEMP TEMPERATURE DP DISTRIBUTION PANEL MH MANHOLE TSP TWISTED SHIELDED PAIR DPDT DOUBLE POLE DOUBLE THROW MIN MINIMUM TYP TYPICAL DPST DOUBLE POLE SINGLE THROW MISC MISCELLANEOUS UG UNDERGROUND DWG DRAWING MOV MOTOR OPERATED VALVE UH UNIT HEATER (E) EXISTING MS MOTOR STARTER V VOLTS EA EACH MTD MOUNTED VA VOLT-AMPERES EF EXHAUST FAN MTG MOUNTING VFD VARIABLE FREQUENCY DRIVE EHH ELECTRICAL HANDHOLE MTS MANUAL TRANSFER SWITCH VAR VOLT AMPERES REACTIVE EL, ELEV ELEVATION (N) NEW VERT VERTICAL ELEC ELECTRIC, ELECTRICAL NC NORMALLY CLOSED VH VAR -HOUR ELEM ELEMENTARY NEC NATIONAL ELECTRICAL CODE VS VOLTMETER SWITCH EMERG EMERGENCY NEMA NATIONAL ELECTRICAL W WIRE, WATTS ENCL ENCLOSURE MANUFACTURER'S ASSOC. WHIM WATTHOUR METER EQ EQUAL NEUT NEUTRAL WHDM WATTHOUR DEMAND METER EQPT EQUIPMENT NIC NOT IN CONTRACT WP WEATHERPROOF ETM ELAPSED TIME METER NO NORMALLY OPEN, NUMBER WT WATERTIGHT FDR FEEDER WTP WATER TREATMENT PLANT XFMR TRANSFORMER GENERAL NOTES: G1. THESE DRAWINGS ARE G2. THIS IS A GENERALIZED LEGEND G4. INFORMATION SHOWN MAY NOT DIAGRAMMATIC ONLY; EXACT SHEET. THIS CONTRACT MAY BE ALL INCLUSIVE. SEE ALSO LOCATIONS OF ELECTRICAL NOT USE ALL INFORMATION ANSI C37.2, Y1.1, Y32.2, AND EQUIPMENT SHALL BE DETERMINED SHOWN. Y32.9. IN THE FIELD BY THE ENGINEER. G5. VERIFY ALL COLOR THE INSTALLATION OF ALL G3. NOTIFY THE ENGINEER REQUIREMENTS BEFORE EQUIPMENT SHOWN ON THESE IMMEDIATELY IF CONFLICTS IN ORDERING MATERIALS. DRAWINGS OR DESCRIBED IN THE EQUIPMENT LOCATIONS ARE SPECIFICATIONS SHALL CONFORM TO DISCOVERED OR IF PROBLEMS G6. REFER TO THE MECHANICAL THE REQUIREMENTS SET FORTH IN ARISE DUE TO FIELD CONDITIONS, DRAWINGS FOR CERTAIN THE LATEST EDITIONS OF ALL LACK OF INFORMATION OR ANY CONTROL DIAGRAMS AND APPLICABLE CODES AND UTILITY OTHER REASON. NO PAYMENT EXACT LOCATIONS OF COMPANY STANDARDS. CONTACT WILL BE MADE FOR CHANGES MECHANICAL EQUIPMENT AND THE UTILITY COMPANY WHICH HAVE NOT BEEN FOR CERTAIN CONNECTIONS TO REPRESENTATIVES AND VERIFY FAVORABLY REVIEWED BY THE BE MADE TO ELECTRICAL THEIR REQUIREMENTS ENGINEER. CIRCUITS. PLAN NOTES: P1. CONDUIT SIZE AND FILL SHALL BE AS INDICATED WHERE NO SIZE IS SHOWN, THE CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE EDITION OF THE NATIONAL ELECTRICAL CODE ADOPTED BY THE AUTHORITY HAVING CODE ENFORCEMENT JURISDICTION. WHERE NO FILL IS INDICATED, THE FILL SHALL BE 2#12. PROVIDE 3/16 INCH NYLON PULL ROPE IN EACH EMPTY CONDUIT. P2. CONDUIT AND WIRE LAYOUT FOR LIGHTING AND RECEPTACLES NOT SHOWN. PROVIDE PER NEC. P3. LETTERS ADJACENT TO A LIGHT FIXTURE INDICATE CIRCUIT INFORMATION. THE FIRST LETTER DENOTES THE FIXTURE TYPE PER THE FIXTURE SCHEDULE. PANEL AND CIRCUIT IDENTIFICATION IS SHOWN IN BRACKETS. THE SWITCH IDENTIFICATION IS SHOWN AS A LOWER CASE LETTER. P4. NUMBER OF CIRCLES DOES NOT REPRESENT THE NUMBER OF CONDUITS IN THE ENCASEMENT. ROTFIHI Roth Hill, LLC Tel 425.869.9448 www.rothhill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 Kennedy/Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, WA 98001 Ph. 253-835-6400 Fax 253-952-3435 PLAN SYMBOLS OH OVERHEAD POWER LINE UNDERGROUND CONDUIT UNDERGROUND DUCT LINE (CONCRETE ENCASEMENT) 01 NOTE P4 UNDERGROUND DIRECT BURIAL CONDUITS NOTE P4 O MULTIPLE CONDUIT RUN CONDUIT CONCEALED IN FLOOR - - - - - - - - CONDUIT CONCEALED IN WALL & CEILING CONDUIT EXPOSED CALLOUT INDICATING CONDUIT 3/4"C-3#12, SIZE, NUMBER OF WIRES AND 1#12G WIRE SIZE CALLOUT INDICATING CONDUIT 100 PER SCHEDULE CONDUIT RUN, HATCH MARKS INDICATE NO. OF #12 CONDUCTORS NO HATCH MARKS IS 2#12 UNLESS OTHERWISE NOTED CONDUIT RUN, HATCH MARKS #10 INDICATE NUMBER OF CONDUCTORS III CALLOUT INDICATES CONDUCTOR SIZE HOME RUN TO PANELBOARD OR AS INDICATED FLEXIBLE CONDUIT CONDUIT RUN, BROKEN AND CONTINUED ON SAME SHEET OR AS NOTED CONDUIT WITH SEAL FITTING ] CAP ON CONDUIT STUB OPEN CIRCLE DENOTES UPWARD CONDUIT RISER SOLID CIRCLE DENOTES DOWNWARD CONDUIT RISER INDICATES REMOVAL F FIRE ALARM CONDUIT T TELEPHONE CONDUIT T/D TELEPHONE/DATA CONDUIT SURFACE MOUNTED PANELBOARD FLUSH MOUNTED PANELBOARD O MOTOR DISCONNECT SWITCH COMBINATION MOTOR STARTER AND DISCONNECT SWITCH SMS MANUAL MOTOR STARTER ❑e CONTROL STATION �— EQUIPMENT MOUNTING STAND GROUND ROD AND BOX ® INSTRUMENT ❑D MAGNETIC DOOR HOLDER K] INTRUSION REMOTE KEY PAD O INTRUSION DOOR SWITCH SAP SECURITY ALARM PANEL S SECURITY ALARM CONDUIT PA PUBLIC ADDRESS INDOOR SPEAKER �PAJ PUBLIC ADDRESS OUTDOOR SPEAKER PA PUBLIC ADDRESS CONDUIT S* SINGLE POLE SWITCH �k 2= 2 POLE, 3= 3 WAY, 4= 4 WAY, K = KEY OPERATED WP = WEATHERPROOF D = DIMMER P = SWITCH WITH PILOT LIGHT Sab SINGLE POLE SWITCH (NOTE P3) Sab DUAL RELAY WALL SWITCH INFRARED OCCUPANCY SENSOR O FLUORESCENT FIXTURE (NOTE P3) O FLUORESCENT FIXTURE WITH NIGHT LIGHTING (UNSWITCHED) OR FLUORESCENT FIXTURE WITH SELF-CONTAINED EMERGENCY BALLAST/BATTERY ❑ WALL/CEILING MOUNTED FIXTURE j �( WALL/CEILING MOUNTED FIXTURE ' N� �1,� NIGHT LIGHTING (UNSWITCHED) 0-0 POLE MOUNTED FIXTURE WALL/CEILING MOUNTED EXIT b ®b LIGHT - DIRECTIONAL ARROW WHERE INDICATED, SHADED AREA INDICATES ILLUMINATED FACE EMERGENCY LIGHT WITH SELF CONTAINED BATTERY A(LX-X)a LIGHT FIXTURE IDENTIFICATION (NOTE P3) IO SINGLE RECEPTACLE, 120V H� SINGLE RECEPTACLE, 208V OR 240V DUPLEX WALL RECEPTACLE, 120V WP = WEATHERPROOF G = GROUNDED IG = ISOLATED GROUND GF = GROUND FAULT INTERRUPTER DOUBLE DUPLEX WALL RECEPTACLE 120V DUPLEX FLOOR RECEPTACLE, 120V MULTI -OUTLET ASSEMBLY WITH DUPLEX RECEPTACLE, 120V. SPACING AS NOTED, MOUNTING HEIGHT AS NOTED. SD RECEPTACLE, 480V I_ O WALL/CEILING MOUNTED '��J JUNCTION BOX FLOOR RECESS MOUNTED JUNCTION BOX ST THERMOSTAT, WALL MOUNTED Q WALL TELEPHONE OUTLET ® FLOOR TELEPHONE OUTLET T WALL TELEPHONE/DATA OUTLET u FLOOR TELEPHONE/DATA OUTLET r LTJ FIRE ALARM PULL STATION MF FIRE ALARM HORN `ice FIRE ALARM HORN WITH VISUAL OHEAT DETECTOR OSMOKE DETECTOR EOL END OF LINE RESISTOR FACP FIRE ALARM CONTROL PANEL CR CARD READER 0 ❑ ELEC MANHOLE/ELEC HANDHOLE EMH EHH ❑ ❑ SIGNAL HANDHOLE/TEL HANDHOLE SHH THH SINGLE LINE SYMBOLS GROUND CONNECTION 0�0 SWITCH, 3 POLE EXCEPT WHERE NOTED. RATING IN AMPERES AS NOTED AUTOMATIC TRANSFER SWITCH 3 POLE, RATING AS NOTED ST SHUNT TRIP ® FUSE o�o FUSE CUTOUT CIRCUIT BREAKER, 3 POLE EXCEPT WHERE ° MCP ° )OOOAT NOTED. RATING IN AMPERES AS NOTED. IF TWO RATINGS APPEAR (EG. 100/625) THEN 0 OOAT 0 OOOAF DEVICE IS MCP; NUMERATOR IS CONTINUOUS CURRENT RATING & DENOMINATOR IS INSTANTANEOUS TRIP SETTING. POWER CIRCUIT BREAKER DRAWOUT ABOVE 1500V RATING AS NOTED SURGE ARRESTER SCURRENT TRANSFORMER VOLTAGE TRANSFORMER UI)i POWER OR DISTRIBUTION TRANSFORMER RATING AS NOTED 100 MOTOR. NUMBER INDICATES HORSEPOWER OGEN GENERATOR O CONTROL PACKAGE PROVIDED WITH THE DRIVEN EQUIPMENT BUS STAB ON MCC OR SWITCHGEAR, u CORD & PLUG CONNECTION FOR MOTORS o �Cro THERMAL OVERLOAD * A — AMMETER O V — VOLTMETER WH — WATTHOUR METER GS — GROUND FAULT SENSOR AS AMMETER SWITCH VS VOLTMETER SWITCH 127 ELEMENTARY ELEMENTARY DIAGRAM NUMBER K KIRK KEY INTERLOCK POWER RECEPTACLE FOR PORTABLE EQUIPMENT # RELAY DEVICE FUNCTION, # PER ANSI NUMBER C37.2 TERMINATOR / POTHEAD —}— SPLICE, TERMINATION T 2 MOTOR STARTER. NUMBER INDICATES NEMA SIZE ,T` CAPACITOR — KVAR INDICATED AFD * AFD — ADJUSTABLE FREQUENCY DRIVE SSS — SOLID STATE STARTER CALLOUT INDICATING CONDUIT 100 PER SCHEDULE P001 CALLOUT INDICATING CIRCUIT NUMBER PER SCHEDULE SPD SURGE PROTECTIVE DEVICE SURVEYED: SCALE: VERTICAL: NAVD 1988 - - HORIZONTAL: NAD 1983/1991 DESIGNED: VAB DRAWN: LMM ONE INCH i RECORD DRAWING RFB 20 1 PAR CHECKED: DATUM PAR AT FULL SCALE IF NOT ONE INCH NO. REVISION BY DATE AP P R APPROVED: SCALE ACCORDINGLY ELEMENTARY DIAGRAM SYMBOLS CROSS REFERENCE TO ® FUSE. RATING IN AMPERES ANOTHER DIAGRAM NORMALLY OPEN CONTACT M MOTOR ETM ELAPSED TIME METER ON THE OTHER DIAGRAM 1)_ 2-2, 3, 0, 0 /1 7 * * CONTROL DEVICE COIL. PREFIX NUMBER, CIR - S WHEN USED, DISTINGUISHES BETWEEN SPARE CONTACTS ON RELAY. DEVICES OF THE SAME TYPE. IF OMITTED, THEN THE SPEC. REQUIREMENTS REGARDING ALT - ALTERNATOR LR - LATCH RELAY SPARE CONTACTS APPLY. CR - CONTROL RELAY SV - SOLENOID VALVE NORMALLY CLOSED CONTACT GR - GENERAL RELAY PR - PROBE RELAY ON THIS DIAGRAM ISR - INTRINSICALLY SAFE TR - TIMING RELAY RELAY INDICATING LIGHT o * PUSH -TO -TEST INDICATING LIGHT 1 f0 * COLORS: A - AMBER R - RED B - BLUE N - NEON C - CLEAR W - WHITE G - GREEN Y - YELLOW 0N OFF SINGLE POLE SWITCH EMERGENCY PUSHBUTTON 0 0 �Q PUSHBUTTON, 0 0 NORMALLY OPEN / CLOSED 0 -0 o% vI SWITCH, ° ISO 1-POLE / 3-POLE I 0�0 MULTI —POSITION SELECTOR SWITCH 0 H 0 A HAND -OFF -AUTOMATIC SWITCH I` I X-INDICATES CONTACTS CLOSED I I I S0 1 0->K- H1 H3 H2 H4 X1 X2 SENSING SWITCHES CLOSE ON SENSED VARIABLE RISING FALLING FLOW LEVEL O-Z PRESSURE TEMPERATURE LIMIT SWITCHES V CLOSE ON REACHING LIMIT 0­__j6 CLOSE ON LEAVING LIMIT TIMED CONTACTS SYMBOL NORMAL OPEN TO CLOSED CLOSED TO OPEN 0-f OPEN DELAYED INSTANTANEOUS CLOSED INSTANTANEOUS DELAYED OPEN INSTANTANEOUS DELAYED CLOSED DELAYED INSTANTANEOUS HAND -OFF -REMOTE SWITCH ELEMENTARY DIAGRAM NOTES: X-INDICATES CONTACTS CLOSED E1. UNDERLINED WORDS SHOWN AT A PUSHBUTTON, LIGHT, SELECTOR SWITCH, ETC. INDICATE THE LEGEND PLATE REQUIREMENT FOR THAT PARTICULAR DEVICE. ANY ADDITIONAL NAMEPLATES ARE INDICATED ON ELEVATIONS WITH THE REQUIRED NAMEPLATE INSCRIPTIONS. TERMINAL E2• "NORMAL" STATUS OF SWITCHES OR CONTACTS IS THE SHELF POSITION. E3. NUMBERS AND LETTERS IDENTIFY DEVICE. CONTROL POWER TRANSFORMER MOTOR HEATER MOTOR HEATER o I o 0 4--, CIRCUIT BREAKER, o ° I ° 1—POLE / 3—POLE 0 GROUND CONNECTION CONTACT, NORMALLY OPEN / CLOSED BUS STAB ON MCC; CORD & PLUG CONNECTION FOR MOTORS OL OjXro THERMAL OVERLOAD g BELL �1 HORN S=347329 RECORD DRAWING These Record Drawings have been prepared based on information provideti by the contractor and others. Kennedy/Jenks Consultants has not verified the accuracy or completeness of information provided to them and does not warrant the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loss resulting from their use. �31892 �QVAL � DATE: '4R STONEGATE 05-24-2010 CITY OF LIFT STATION REPLACEMENT FlELDBOOK: RENT 0 N PAGE: DRAWING NO: Planning/Building/Public Works Dept. ELECTRICAL ABBREVIATIONS AND SYMBOLS El SHEET: OF: 29 42