Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WTR2703488.8
EXISTING LIGHT FIXTURE AND MOUNTING BRACKETS (TYPICAL OF 5). CONTRACTOR SHALL REPLACE EXISTING LIGHT FIXTURE AND MOUNTING BRACKETS WITH PROPOSED LIGHT FIXTURE AND MOUNTING BRACKETS AS SHOWN IN LANDING LIGHT AND STAIRWAY LIGHT DETAILS THIS SHEET. ., 20"W X 25 3/4„H X 3/8" D STAINLESS STEEL PLATE. EXISTING LIGHT REPLACEMENT DETAIL NO SCALE LOWER ACCESS LANDING PROPOSED LOWER ACCESS LANDING HATCH INTRUSION SWITCH PROPOSED CONDUIT AND HARING. ROUTE CONDUIT INSIDE VANDAL SHIELD AND SECURE CONDUIT EVERY 3'-0" ALONG LADDER. PROPOSED VANDAL SHIELD INTRUSION SWITCH. CONTRACTOR SHALL USE LEVER ARM SPECIFlED ON DWG NO. E03. CONTACT SHALL BREAK WHEN SHIELD IS OPENED. SECURE 3/8" THICK STAINLESS STEEL PLATE ON INSIDE OF RAILING IN 4 LOCATIONS USING STAINLESS STEEL U—BOLTS. LOWER ACCESS SECURE BOTTOM OF LANDING 3/8" THICK STAINLESS GUARDRAIL. STEEL PLATE TO LOWER ACCESS LANDING BRACKET IN 2 SECURE TOP OF 3/8" LOCATIONS USINGSTAINLESS STEEL THICK STAINLESS STEEL BOLTS. PLATE ON INSIDE B GUARDRAIL IN 2 0 LOWER LOCATIONS USING __-j ACCESS STAINLESS STEEL ! LANDING U-BOLTS. SPIRAL r STAIRCASE ICI EXISTING ROOF ACCESS HATCH JUNCTION BOX. CONTRACTOR SHALL SPLICE EXISTING ROOF ACCESS HATCH INTERIOR LIGHT FIXTURE CONDUCTORS WITH PROPOSED LIGHT 20"W X 16 1/4"H X 3/8" D SWITCH CONDUCTORS WITHIN JUNCTION BOX. STAINLESS STEEL PLATE. RAILING PROPOSED LOWER ACCESS PROPOSED RESERVOIR STAIRWAY LANDING LIGHT MOUNTING DETAIL LIGHT MOUNTING DETAIL NOT TO SCALE © SEE DWG NO. E03 FOR EQUIPMENT AND INSTRUMENTATION SCHEDULE. LOWER ACCESS LANDING LADDER nurn ACCESS LANDING HATCH Hai PROPOSED CONDUIT AND WIRING TO EXISTING TELEMETRY PANEL i PROPOSED VANDAL SHIELD AND LOWER ACCESS LANDING A INTpIMICIN SWITf:N r1FT011 Eo, NOT TO SCALE NOT TO SCALE NOTE: PROPOSED SPARE CONDUITS AND CONDUITS CONTAINING ANTENNA CABLES SHALL HAVE SWEEPS ONLY. CONDUIT TEES, ELBOWS, OR LB'S SHALL NOT BE ALLOWED UNLESS SPECIFIED. EXISTING ANTENNA CABLE EXISTING LIGHT FIXTURE AND MOUNTING BRACKETS TO BE REPLACED, PROPOSED ANTENNA CONDUIT J1 TYPICAL. SEE THIS CONTRACTOR SHALL PULL EXISTING SHEET FOR DETAIL. ANTENNA CABLE THROUGH PROPOSED CONDUIT TO EXISTING RADIO EQUIPMENT LOCATED WITHIN EXISTING ELECTRICAL CABINET. TO EXISTING RADIO EQUIPMENT LOCATED WITHIN EXISTING ELECTRICAL CABINET, "EC-1" m PROPOSED CONDUITS, SEE DWG N0. E03 FOR DETAIL PROPOSED CONDUIT -- AND CABLE CHASE. EXISTING CONDUIT a � AND CABLE CHASE. PROPOSED ANTENNA CONDUIT DETAIL NOT TO SCALE EXISTING ROOF ACCESS HATCH _ TO PROPOSED LIGHT SWITCH TO EXISTING ROOF ACCESS HATCH ;I f JUNCTION BOX. PROPOSED LIGHT SWITCH DETAILS D NOT TO SCALE E01 EXISTING YAGI ANTENNA, TO BE lwwREMOVED. EXISTING YAGI ANTENNA CABLE, TO BE REMOVED. EXISTING RESERVOIR SHELL PROPOSED CONDUIT, TYPICAL PROPOSED STAINLESS STEEL CONDUIT CLAMPS. SECURE CONDUIT CLAMP TO rys EXISTING CONDUIT/CABLE TOP OF EXISTING CONDUIT/CABLE SUPPORT BRACKETS SUPPORT BRACKETS, TYPICAL. CONTRACTOR SHALL PROVIDE AND INSTALL CONDUIT EXTENSION CLAMPS AS NECESSARY ON EXISTING SUPPORT BRACKETS SO THAT ALL PROPOSED, CONDUITS WALL FIT BELOW EXISTING STAIRWAY. CONDUIT SUPPORT DETAIL NO SCALE REVISED TO CONFORM TO CONSTRUCTION RECORDS 03122111 RH2 ENGINEERING AC'. DATE SEE DWG NO. E01 FOR PROPOSED CONDUIT CONTINUATION. EXISTING CONDUIT AND CABLE TRAY PROPOSED LIGHT SWITCH. CONTRACTOR SHALL MOUNT PROPOSED LIGHT SWITCH TO INSIDE OF EXISTING TOP RAILING NTH STAINLESS STEEL HARDWARE. EXISTING SHED EXISTING ELECTRICAL CABINET, "EC-1" INSTALL FLEXIBLE METAL CONDUIT AT BENDS FOR CIRCUITS J1, AND J3 TO PREVENT 90' BEND IN ANTENNA CABLES. CONDUITS SHALL TRANSITION TO RIGID CONDUIT FOR STRAIGHT VERTICAL RUNS. FLEXIBLE CONDUIT SHALL BE SUPPORTED WITH UNISTRUT PER NEC. EXISTING RESERVOIR FOUNDATION H 672? �19Tt4t'91 3MAI, SIGNED: 04 /23/10 SIGNED. 04123,/10 o z Q �► QaA cn V T J Q W 0 Q W J W 0 W cn W ENGINEERS PLANNERS PROPOSED CONDUIT SCIENTIST S ROUTING DETAIL RH2 ENGINEERING, INC. http: ;`jwww.rh2.cam NOT TO SCALE mailbox®rh2.com 1.800.720 $05? BELLINGHAM 3w.6 454 West Horton Road CENTERLINE OF CENTERLINE OF BOTHELL 425s81 CONDUCTORS/CORDS 12100 NE 195th Street, Su - OF OF CONDUIT "Cl" PROPOSED OF CONDUIT "C2" PROPOSED ENATCHEE soo.as CONDUIT "C2" CONDUIT "Cl" 300 Simon Street, Suite 5 RICHLAND 509.9".5181 114 Columbia Point Drive, Suite C SILVERDALE 2021 NW Mhyre Rc TACOMA 2: PROPOSED CONDUIT SCALE: SHOWN TEE ADAPTER PROPOSED CONDUIT "C3" j 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG W=341 8808 Pl 48 EN(,'MFh DY E02 PROPOSED CONDUIT TEE CONNECTION DETAIL E DATE:REVIEED MAR SHEF Nji- E01 °A� MAR 23, 2011 NOT TO SCALE CLIENT REN 07 REVISED TO CONFORM TO CONSTRUCTION RECORDS MWB CMR 03/22/11 Boa No 109-062 09 NO REVISION BY REVIEW DATE FILENAME WHR—D—ELECO2