Loading...
HomeMy WebLinkAboutWTR2703488.9KEY SYSTEM REQUIREMENTS CONTRACTOR SHALL COORDINATE WITH CITY FOR DETAILS ON PROVIDING A, CORE SYSTEM THAT MEETS CITY OF RENTON STANDARDS. SEE SPECIFICATIONS. HINGED DOOR. CONTRACTOR SHALL MOUNT SECURITY LOCK IN DOOR. LOCK SHALL BE A BEST LOCK MODEL NO. 1E7D4 WITH CONSTRUCTION CORE, NO SUBSTITUTIONS. KEYED SWITCH BOX OBLIQUE NOT TO SCALE NOT TO SCALE KEYED SWITCH BOX DETAILS NO SCALE H 120 VAC CIRCUIT IN LIGHTING PANEL I I I 20 AMP PROPOSED LIGHT SWITCH TO INTERIOR BREAKER F RESERVOIR LIGHT LOCATED IN I fj RESERVOIR ROOF ACCESS HATCH. SWITCH EXISTING INTERIOR LIGHT FIXTURE i/4" GRC CONDUIT TO EXISTING 3/4" GRC CONDUIT TO TELEMETRY PANEL, "RTU". -'"- -I I I �-- EXISTING ELECTRICAL EXISTING TELEMETRY -- I 10" �� CABINET, EC-1 . PANEL, "RTU". O O 1/2" LB, TYP. INTRUSION ALARM DISABLE 1/2" FLEX FROM BOX TO RIGID CONDUIT, TYP. EXISTING 240/120 VAC, 1�, 3-WIRE KEY SWITCH AND KEY BOX KEY X. POWER PANELBOARD, CONTRACTOR . BEST MODEL N0. PROPOSED RESERVOIR SHALL INSTALL A 50 AMP 2-POLE WITH CONSTRUCTION CORE. 12" STAIRWAY LIGHT SWITCH CIRCUIT BREAKER IN EXISTING POWER NO SUBSTITUTIONS. SECURE 12" H x 10" W x 6" D PANELBO TO SUB -FEED JUNCTION BOX RIGIDLY TO OO 8 NEMA 4 JUNCTION BOX. PROPOSED ELECTRICAL RICAL CABINET, HOFFMAN ENCLOSURE WITH HOFFMAN MODEL NO. - "EC 2", LOAD CENTER, "L2". INSTALL A MINIMUM OF (1) NO. 10 j L-P3025 OR EQUAL. A 15 AMP, 1-POLE CIRCUIT BREAKER SHEET METAL SCREWS EACH 2" SECURE BOX RIGIDLY TO IN EXISTING POWER PANELBOARD FOR CORNER. EXISTING COVER SUPPORT POWERING PROPOSED CATHODIC DOOR NOT SHOWN THIS USING (4) 1/4" BOLTS. PROTECTION RECTIFIER. vlEw FOR CLARITY. KEYED SWITCH BOX DETAIL EXISTING MAIN SERVICE DISCONNECT SWITCH PROPOSED INTRUSION DISABL KEYSWITCH ENCLOSURE 7 PROPOSED INTRUSION ALARM N HORN �1 PROPOSED CATHODIC I PROTECTION SYSTEM RECTIFIER EXISTING SEWER REPEATER —, C9 PANEL TO BE RELOCATED. SEE PROPOSED LOCATION IN "EC-2". FINISHED GRADE • Q • L ' PROPOSED EXISTING CONDUCTOR, CONDUCTOR, TYPICAL TYPICAL RESERVOIR LIGHT SWITCH CIRCUIT 01 PPRO; CABINET DEPTH I f EXISTING CABINET SUPPORTS PROPOSED LOCKING DOOR HANDLE, TYP OF 2. ZINC DIECAST, PADLOCK HANDLE. PROPOSED DOOR HINGES, TYPICAL NO SCALE PROPOSED DOORS TO REPLACE '— EXISTING PANEL DOORS PROPOSED STEEL PIANO HINGE, APPROX FULL f i 1 HEIGHT OF DOORS. PROPOSED STEEL FLANGE TO BE WELDED TO EXTERIOR OF CABINET. CONT FULL PERIMETER EXISTING ELECTRICAL CABINET, "EC-1". CONTRACTOR SHALL VERIFY DIMENSIONS OF EXISTING ELECTRICAL CABINET PRIOR FLANGE FABRICATION. CABINET PLAN NOTES: - CONTRACTOR TO PROVIDE GASKET BETWEEN FLANGE AND DOOR TO ENSURE wEATHERTIGHT SEAL. - PROPOSED FLANGE AND DOORS TO BE COATED STEEL PER SPECIFICATIONS. - DOOR HINGES SHALL HAVE SST PIN WITH LEAFS COATED PER SPECIFICATIONS u F-- APPROX 7'-0' —1 FRONT VIEW WITH PROPOSED DOORS NOT TO SCALE PROPOSED NEMA 4 DOUBLE DOORS WITH GASKETING, PAINTED WHITE. PROPOSED DOORS SHALL BE SIZED TO FIT PROPOSED MOUNTING BRACKET. OUTLINE OF EXISTING ELECTRICAL CABINET, "EC-1" PROPOSED CABINET DOOR EXISTING ELECTRICAL CABINET, "EC-1" EXISTING COVER EXISTING WI-FI PANEL SEE DWG NO. E01 FOR SEE THIS SHEET FOR G�,4� oI WAS CONTINUATION. CONTINUATION. q� I PROPOSED NEMA 4 STEEL ELECTRICAL CABINET, 1ISTIS "EC-2", PAINTED WHITE, 7'W X 30"D X 4'H. CBrONALl PROPOSED ENCLOSURE SHALL BE A CUSTOM CABINET O� MANUFACTURED BY HOFFMAN OR EQUAL. \ J2 ppnonc�n rn��Q i SPACE FOR FUTURE ' RELOCATION OF -. ____ .____. PROPOSED ELECTRICAL CABINET, PROPOSED WI-FI PANEL "EC-2", LOAD CENTER, "L2". RECEPTACLE P4 EXISTING RADIO EQUIPMENT EXISTING WI-FI PANEL JUNCTION BOX P2 P8 P9 P10 4 d SURFACE MOUNT PROPOSED CONDUITS TO EXISTING TANK. CONTRACTOR SHALL WELD UNISTRUT CONDUIT MOUNTING BRACKETS TO TANK FOR `- SURFACE MOUNT INSTALLING PROPOSED CONDUITS. EXISTING SEWER CONTRACTOR SHALL PAINT PROPOSED CONDUITS REPEATER PANEL AND MOUNTING BRACKETS TO MATCH TANK COLOR. RELOCATED. MAINTAIN 2 SEPARATION FROM TANK SURFACE. PANEL RELOCATION DETAIL F NOT TO SCALE E01 ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE ITEM - 'ON MANUFACTURER MODEL NO. O LOAD CENTER - NEMA 12 ENCLOSURE, THERMAL MAGNETIC SQUARE D 50 AMP MAIN CIRCUIT BREAKER, 12 CIRCUIT, 240/120 VAC, 1�, QO SERIES OR EQUAL 3-WIRE. © OUTDOOR AREA WALL LIGHT - 120 VAC, (1) - 150 WATT ELCAST 850-S-INC-120-BZ-G INCANDESCENT LAMP, DIE-CAST ALUMINUM HOUSING, IMPACT RESISTANT GLASS LENS, U.L. LISTED FOR WET LOCATIONS, SURFACE MOUNT TO RAILING PER DETAILS ON DWG NO. E02. © INTRUSION ALARM SWITCH - HEAVY DUTY ALARM SWITCH, SQUARE D TYPE C, CLASS 9007 CONTRACTOR SHALL USE ADJUSTABLE LENGTH LEVER ARM WITH OR EQUAL STEEL ROLLER 9007 HA1, WIRE IN SERIES. ALARM ANNUNCIATION HORN - 24 VDC. UNIT SHALL PRODUCE FEDERAL SIGNAL 99 dB VIBRATONE SOUND BLAST AT 10 FEET. THE UNIT SHALL 450 BE RATED FOR OUTDOOR USE. PANEL SCHEDULE L2 NO. L2 LOCATION: ELECTRICAL CABINET, "EC-2" SERVING: WEST HILL RESERVOIR 1 3 5 7 19 11 2 4 6 8 10 12 240/120 VOLTS 3 WIRE 50 AMP MAIN CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION ELECTRICAL CABINET "EC-2", RECEPTACLE 0.18 20 20 0.65 SEWER REPEATER PANEL SPARE - 20 20 - SPARE SPARE - 20 20 - SPARE SPARE - 20 20 - SPARE SPACE - - SPACE SPACE - - - - SPACE CONNECTION LOAD: DEMAND: LIGHTING AND CONTROL LOAD DEMAND LOAD: .83 KVA 3.46AMPS .83 KVA 3.46AMPS PROPOSED PIANO HINGE W/ SST PIN. SEAL WELD TO DOOR AND FLANGE. CONTRACTOR TO SIZE HINGE TO SUPPORT CABINET DOOR. „ HINGE TO HAVE LEAF OFFSET TO ACCOUNT FOR GASKET THICKNESS. ~�- PROPOSED FLANGE EXISTING CABINET - HINGE DETAIL B2 4" = 1'-0" 03 GASKET, CONT FULL PROPOSED 2"xY4" PL, CONT PERIMETER 1/8 PROPOSED PANEL DOOR EXISTING CABINET ENCLOSURE EXISTING ELECTRICAL CABINET DOOR REPLACEMENT DETAILS B NOT TO SCALE E01 SECTION a4"-1 REVISED TO CONFORM TO CONSTRUCTION RECORDS 03 22 11 RH2 ENGINEERING INC. DATE EXISTING ANTENNA a a SPACE FOR FUTURE RELOCATION OF WI-FI JUNCTION BOX FINISHED GRADE J2 C8 EXISTING STAIRCASE AND RAILING f' EXISTING SEWER REPEATER PANEL CONDUIT PROPOSED CONDUIT J2 CONTRACTOR SHALLINTERCEPT EXISTING SEWER REPEATER PANEL CONDUIT WITH PROPOSED CONDUIT. CONTRACTOR SHALL PULL AND RE-ROUTE EXISTING SEWER REPEATER PANEL CABLES/CORDS THROUGH PROPOSED CONDUIT INTO RELOCATED EXISTING SEWER REPEATER PANEL. PROPOSED CONDUIT AND CABLE CHASE SIGNED: 04 23 '10 SIGNED: 04123110 U 7�N F-i O fi+ �..I.y OVA x V — (n _J — Q W 0 J Q V - cc W J W — O W W SCALE: SHOWN 6m� 0 1" 2" DRAWING IS NOT TO SCALE W 348809 TO RELOCATED `�'� IF BAR IS NOT 2" LONG EXISTING SEWER PLOT: 12 REPEATER PANEL. ENGINEER DY E03 EXISTING SEWER REPEATER CONDUIT CONNECTION DETAIL DATE � CMR C onTE APR 27, 2011 JJ�� L NOT TO SCALE E01 O i.+�,. i ` 1 " CLIENT: REN REVISED TO CONFORM TO CONSTRUCTION RECORD MWB CMR 03/22/11 JOB NO 109-062 09 NO. REVISION BY REVIEW DATE I HLENAME WHR-D-ELEC03