HomeMy WebLinkAboutWTR2703514.4i- i
Ln
(Yi
i
N
i
ri
S
Q
a
N 189,026t
E 1,309,735+
CONNECT TO EX/STING 8 " W
8 " x 8" VERTICAL CROSS (MJ x FL)
2- 8" BLIND FLANGES
2- 8" 90° BEND (MJ)
N 189,033 8" SLEEVE (MJ) OR ROMAC ADAPTOR
E 1, 309,734 CONCRETE BLOCKING
8 x 6 TEE (MJ x FL) SEE CONNECTION D TAIL 1, SHT W-3
6" GV (FL x MJ)
HYDRANT ASSEMBL Y
SHACKLEALL FITTINGS
REMOVE EXISTING HYDRANT
SE
o
�
�
1
1
'1
1
1
I
1
3
/
I
I
/
C)
1
1
I
1
I
CO
�'/
I
SD4
/
c -rl
N 189,.033
E 1, 309,734
...................................................................................................................
ASBUIL T
AUGUST2010 SURVEYED: SCALE:
ASBUIL T FROM INFORMA TION ` 1 "=20'
y DESIGNED:
AS PROVIDED BY TOUMA MAB
DRAWN:
MAB
ENGINEERING
ONE INCH
CHECKED: AT FULL SCALE
DMC IF NOT ONE INCH
N 0. REVISION BY DATE A P P R APPROVED: SCALE ACCORDINGLY
LH
0
DETAIL I
CONNECTION 126TH AVE NE AND SE 104TH ST
2 - 8" TEES (MJ x MJ)
8" SPOOLS AS NEEDED
8" CAP OR PLUG (MJ) EXISTING MAIN
THRUST BLOCKING AS INDICATED
ALL FITTINGS SHALL BE RESTRAINED
WITH MEGA -LUGS
DETAIL 2
EAST CONNECTION 126TH AVE NE AND SE 100TH ST
8 " x 6" TEE (MJ x FL)
6" GV (FL x MJ)
6" x 6" TEE (MJ x MJ)
6" SPOOLS AS NEEDED
6" SOLID SLEEVE (MJ) OR ROMAC ADAPTOR
6" CAP OR PLUG (MJ) EXISTING MAIN
THRUST BLOCKING AS INDICATED
ALL FITTINGS SHALL BE RESTRAINED
WITH MEGA -LUGS
W=3 51404
DATE:
VERTICAL: NAVD 1988
CITY OF
HORIZONTAL: NAD 1983/183�1991 � SEPT 2009
WATER MAIN REPLACEMENT FIELDBOOK:
RENTON }h AVEPAGE:
DATUM 126th SE DRAWING NO:
Planning/Building/Public Works Dept. SE 100TH STREET TO SE 104TH STREET W-3
SHEET: OF:
4 8
IJ-131JI141
Y
yy
t7
N
(D
to n
z
y
�