Loading...
HomeMy WebLinkAboutWTR2703530.12I MOTORS AND POWER EQUIPMENT RACEWAY SYMBOLS FIRE DETECTION AND ALARM ABBREVIATIONS �I O GROUND ROD IN GROUND ROD BOX TI TRANSFORMER MOTOR STARTER W/DISC❑NNECT �1 DISC❑NNECT SWITCH, NON FUSED u 60A (60A) INDICATES AMPERAGE RATING DISC❑NNECT SWITCH, FUSED 100=SWITCH RATING, €10=FUSE RATING UTILITY METERING MOTOR O PANELB❑ARD, SWITCHBOARD, MCC ® 50A FUSE WITH AMPERE RATING PACKAGED POWER AND CONTROL PANEL UTILITY METERING GROUND 0 DISCONNECT OR SWITCH ivrn TRANSFORMER I 15/1 THERMAL MAGNETIC CIRCUIT BREAKER, RATING/N❑, P ° MO = MAGNETIC ONLY THERMAL OVERLOAD RELAY ATS - AUTOMATIC TRANSFER SWITCH o MTS - MANUAL TRANSFER SWITCH �XKVAR POWER CAPACITOR WITH KVAR RATING VFD = VARIABLE FREQUENCY DRIVE VFD VSD = VARIABLE SPEED DRIVE SSS = SOLID STATE STARTER 15 MOTOR - NUMBER '15' INDICATES HORSEPOWER MS �I MS OR M = MOTOR STARTER CONTACTOR C = C❑NTACT❑R, BP = BYPASS CONTACTOR IC = ISOLATION CONTACTOR r 3 CURRENT TRANSFORMER , NUMBER '3' �— INDICATES NUMBER OF C.TS, PULL OUT SWITCH/PLUG-RECEPTACLE CONNECTION CONTROL AND INSTRUMENTATION 0 N.D. N,❑. H A NORMALLY NORMALLY X00 HOA = HAND/OFF/AUTO SWITCH OPEN CLOSED I HOR = HAND/OFF/REMOTE SWITCH 0 ❑CA = ❑PEN/CLDSE/AUT❑ SWITCH 00X R❑ = RUN/OFF SW SIN SWITCH o\o o--° PB OR INDICATING LIGHT R=RED, I PB PUSH BUTTON G=GREEN, A=AMBER, B=BLUE, 0 0 oZo W=WHITE CONTROL RELAY / CONTACTOR NO NC CR 11 X CONTACT FS FS TIME DELAY RELAY O-C O-C FLOW ;WITCH TDR LS LS Q TWISTED SHIELDED PAIR (TSP) °lam w LEVEL SWITCH Q PS PS SV SV SOLENOID VALVE PRESSURE SWITCH TS TS RTM RTM = RUN TIME METER, AMP = AMP METER, ° TEMPERATURE SWITCH CNT = COUNTER NMI = OPERATOR CONTROL INTERFACE (VFD OPERATOR & DISPLAY) ZS ZS LIMIT .'WITCH °�� °d° P) SPEED POT I I I I BATTERY. FT ❑ INSTRUMENT - FS = FLOW SWITCH, FT = FLOW XMTR, PS= PRESSURE SWITCH, PT = PRESSURE XMTR, ZS = LIMIT SW; TCH, VS = VIBRATION HORN SWITCH, VT = VIBRA1ION XMTR, MS = MOISTURE SWITCH - FIE = FLOW ELEMENT, LE = LEVEL ELEMENT, TE = TEMP ELEMENT, BLOWN FUSE INDICATOR LS INSTRUMENT - LS = LEVEL SWITCH, TS = TEMPERATURE SWITCH, OTI R INDICATING LIGHT: (� FIELD INSTRUMENT A = AMBER G = GREEN GIL B = BLUE R = RED W =WHITE ® HEATER - FEAT TRACE HOA W=3 5 31012 HOA i REVISION DATE BY I Al SELECTOR SWITCH: FOR = FORWARD/OFF/REVERSE HOR = HAND/OFF/REMOTE HOA = HAND/OFF/AUT❑ RD = RUN/OFF PDT = POTENTIOMETER H❑L = HIGH/OFF/LOW CONDUIT RUN 3%4"C, UNLESS OTHER WISE SHOWN O SMOKE DETECTOR 4 #12 FOR POWER CIRCUITS TO PANEL A CKT 4>, Ir A-4 RATE OF RISE DETECTOR (HEAT) P-101 TAGGED C❑NDUIT RUN - O LEL GAS DETECTOR SEE C❑NDUIT & WIRE SCHEDULE FOR DETAILS, FIRE ALARM HORN AND STROBE P=POWER, C=CONTROL, S=SIGNAL P❑ FIRE PULL SATATION C UNTAGGED CONDUIT RUN - CONTRACTOR TO _ES PROVIDE ARE ❑BYCTTHEREQUIPMENTOL OR NA M I S C E LLA N O U S SYMBOLS WIRING AS UIIREDCEWAY IN ACCORDANCE TO THE WIRING DIAGRAMS, OR AS SPECIFIED . CONDUIT SIZE PER NEC; MINIMUM 3/4' H HAND CONTROL STATION WITH: 'C' = (120V) #14 CONTROL WIRE, #12 POWER WIRE HOA SWITCH 'S' = TSP SIGNAL WIRE SPEED POT (IF VSD DRIVEN) 'D' = DEVICENET CABLE CONNECTION RUN LIGHT (IF SUBMERSED) 'E' = ETHERNET CABLE CONNECTION (CAT-5) 'F' = FIRE ALARM PANEL CONNECTION PROVIDE CONDUITOF WIRES TURNED UPQEDORRTOWARD, WIRE DIAGRAMS, ONELINES, MISC. RACEWAY TURNED DOWN -- LIGHT DASHED LINE = EXISTING OR FUTU — — CONDUIT CONCEALED NEW W❑RK/EQUIPMENT CONDUIT EXPOSED, CONDUCTORS NOT CONNECTED, OJ CONDUIT JUNCTION BOX PBC HHP PB = PULL BOX HH = HANDHOLE CONDUCTORS CONNECTED, ❑ ❑ C=C❑NTROL, S=SIGNAL, P=POWER C❑NDUIT CAPPED, CORD OR FLEX CONDUIT LIGHTING & RECEPTACLE SYMBOLS FLUORESCENT LIGHTING FIXTURE - SURFACE OR O F1 PENDANT MOUNTED TV INDICATES TYPE PER FIXTURE SCHEDULE Cd�M❑D DUPLEX RECEPTACLE 2a "2" INDICATES CIRCUITING C=CIRCUIT # O F1 I "a" INDICATES SWITCHING MOD = MODIFIER 2a WP = WEATHER PROOF XP = EXPLOSION PROOF GF = GROUND FAULT FLUSH MOUNTED FLUORESCENT LIGHT A,AMP AMPERE AC AIR COMPRESSOR, ALTERNATING CURRENT AF AMPERE FRAME AFF ABOVE FINISHED FLOOR AI ANALOG INPUT PINT (PLC) AIC AMPERES INTERRUPTING CAPACITY AIL AMBER INDICATING LIGHT AL ALARM ALT ALTERNATOR AM AMMETER A❑ ANALOG OUTPUT POINT (PLC) AS AMPERE SWITCH AT AMPERE TRIP ATS AUTOMATIC TRANSFER SWITCH BAT BATTERY BC BATTERY CHARGER BH BLOCK HEATER BIL BLUE INDICATING LIGHT BP BYPASS CONTRACTOR C C❑NDUIT, CONTROL CAP CAPACITOR CB CIRCUIT BREAKER CKT CIRCUIT CNT START COUNTER CID CONTROL PANEL CPT CONTROL POWER TRANSFORMER CR CONTROL RELAY CT CURRENT TRANSFORMER CV CHECK VALVE DB DIRECT BURIED DEM DEMAND DF DEMAND FACTOR DI AC DIGITAL INPUT POINT (PLC) DO AC DIGITAL OUTPUT POINT (PLC) DWG DRAWING E,EXIST EXISTING EF EXHAUST FAN F FUSED FACP FIRE ALARM CONTROL PANEL FS FLOW SWITCH FT FLOW TRANSMITTER FVNR FULL VOLTAGE N❑N-REVERSING FVR FULL VOLTAGE REVERSING G,GND GROUND GEN GENERATOR INDICATES FIXTURE ON EMERGENCY CIRCUIT GFI GROUND FAULT INTERRUPTER GIL GREEN INDICATING LIGHT GRS(GRC) GALVANIZED RIGID STEEL (CONDUIT) FLUORESCENT STRIP LIGHT SURFACE OR PENDANT H HOT, HIGH, HAND MOUNTED (b m(x) SURFACE METAL RACEWAY WITH RECEPTACLE AT X' D.C. HH HAND HOLE HID HIGH INTENSITY DISCHARGE F1 INCANDESCENT, COMPACT FLOURSCENT, OR H.I.D. HOA HAND OFF AUTO (SELECTOR SWITCH) CEILING MOUNTED HS HAND STATION (HOA SWITCH & PDT) FOURPLEX RECEPTACLES HTR HEATER Fl INCANDESCENT, COMPACT FL❑URSCENT, OR IC ISOLATION CONTRACTOR H,I.D. WALL MOUNTED SINGLE RECEPTACLE. ISR INTRINSICALLY SAFE RELAY ® EXIT LIGHT, J INDICATES DIRECTION OF ARROW ® SPECIAL PURPOSE RECEPTACLE, AS NOTED kVA KILO VOLT AMPS kVAR KILO AMP REACTIVE 41 DUPLEX RECEPTACLE MOUNTED 6' ABOVE kVARH AR H KIL❑VDUR COUNTER BACKSPLASH. kW KIL❑WATT W EMERGENCY WALL PACK. Q DATA OUTLET kWH KIL❑WATT HOUR L L❑W H,LD, LIGHTING FIXTURE, POLE MOUNTED. DIC INTERCOM LC LCP LIGHTING CONTACTOR LOCAL CONTROL PANEL Zk SPLIT TELEPNONE DATA OUTLET LE LEVEL ELEMENT PE PHOTO ELECTRIC RELAY . TELEPHONE OUTLET LS LEVEL SWITCH LT LEVEL TRANSMITTER 10 1DD SINGLE POLE SWITCH SUPERSCRIPT CIRCUIT IDENTIFIER (1,2,3, ETC.) AND SWITCHING CONTROL: (a,b,c ETC,) MAY BE D COMBINED INSTRUMENT EXAMPLE la, 6c, 31oC ETC, P-101 RACEWAY TAG - P=POWER, C=CONTROL, S=SIGNAL, D=DATA, T=TELEPH❑NE, S=SPARE INSTRUMENT ("I SUBSCRIPT MODIFIER INDICATES: 2 = DOUBLE POLE 3 = THREE WAY XX EQUIPMENT TAG 4 = FOUR WAY P = WITH PILOT LIGHT K = KEY OPERATED M = MOTOR RATED WP = WEATHER PROOF SHEET NOTE (KEYNOTE) T = TIMER DETAIL NUMBER XP = EXPLOSION PROOF A MC = MOMENTARY CONTACT, THREE POSITION SHEET ON XX D = DIMMER " WHICH DETAIL R = RE❑STATE - SPEED APPEARS CONTROL I Engineering Planning Surveying PenhaNegon Associates Consulting Engineers, Inc. 750 Sixth Street South Kirkland, WA 98033 www.paceengrs.com PH: (425) 827-2014 1-800-945-8408 FAX: (425) 827-5043 Kirkland Seattle t � "041, iRl REFERENCE SYMBOLS SKYWAY WATER AND SEWER DISTRICT DATE FEB 2005 11909 RENTON AVENUE SOUTH DESIGNED TMH SEATTLE, WA. 98178 DRAFTED TMH (206) 772-1580 CHECKED VMF SCALE AS SHOWN TYPE N DESIGNATION 00� P FUNCTION INSTRUMENT NUMBER LTG LIGHTING M METER MCC MOTOR CONTROL CENTER MCP MAIN CONTROL PANEL MFGR MANUFACTURER MH MANHOLE MO MAGNETIC ONLY (CIRCUIT BREAKER) MOV MOTOR OPERATED VALVE MS MOTOR STARTER MTS MANUAL TRANSFER SWITCH N NEUTRAL NC NORMALLY CLOSED NF NON FUSED NO NORMALLY OPEN ❑I OPERATOR INTERFACE ❑IT OPERATOR IN TROUBLE OIL OVERLOAD RELAY ❑T OVER TEMP P POWER PS PUMP STATION PB PUSH BUTTON PBC PULLBOX (CONTROL) PBD PULLBOX (DATA) PBL PUSH BUTTON - LIGHTED PBP PULLBOX (POWER) PBS PULLBOX (SIGNAL) PE PHOTO ELECTRIC RELAY PFR PHASE FAILURE RELAY PLC PROGRAMMABLE LOGIC CONTROLLER PMD POWER MONITORING DEVICE PNL PANEL POT P❑TENTI❑METER PS PRESSURE SWITCH PT POTENTIAL TRANSFORMER PVC POLY VINYL CHLORIDE (CONDUIT) RCP REMOTE CONTROL PANEL RIL RED INDICATING LIGHT RO RUN - OFF RTD RESISTANCE TEMPERATURE DEVICE RTM RUN TIME METER RV REDUCED VOLTAGE RVAT REDUCED VOLTAGE AUTO TRANSFORMER STARTER S SIGNAL SA SURGE ARRESTOR SE SERVICE ENTRANCE SHT SHEET SS STAINLESS STEEL SSS SOLID STATE STARTER SV S❑LEN❑ID VALVE T THERMOSTAT TC TIME CLOCK TD❑D TIME DELAY ON DE-ENERGIZATI❑N TDOE TIME DELAY ON ENERGIZATI❑N TDR TIME DELAY RELAY TEL TELEPHONE TNI TELEPHONE NETWORK INTERFACE TS TEMPERATURE SWITCH TSP TWISTED SHIELDED PAIR TST TWISTED SHIELDED THREE CONDUCTOR (TRIAD) TYP TYPICAL UH UNIT HEATER UPS UNINTERRUPTIBLE POWER SUPPLY V VAULT VS VIBRATION SWITCH VFD VARIABLE FREQUENCY DRIVE VSD VARIABLE SPEED DRIVE W WATT WHIM WATT HOUR METER WIL WHITE INDICATING LIGHT WP WEATHER PROF XFMR TRANSFORMER XP EXPLOSION PROOF XMTR TRANSMITTER ZS LIMIT SWITCH EQUIPMENT TYPE NUMBER P08TSLPPCO01 EQUPMENT DESIGNATION SYSTEM ABBREVIATION PLANT AREA FOLLETT ENGINEERING ELECTRICAL ENGINEERING CONSULTING REDMOND, WA 425-836-3333 DIMMITT BOOSTER STATION ELECTRICAL SYMBOLS AND ABBRIEVATIONS l)� Gr - j 5aU l �' 28947 s`S10 L EXPIRES 1/8/07 JOB NUMBER 03231.00 SHEET E -1 OF EQUIPMENT TYPE NUMBER P08TSLPPCO01 EQUPMENT DESIGNATION SYSTEM ABBREVIATION PLANT AREA FOLLETT ENGINEERING ELECTRICAL ENGINEERING CONSULTING REDMOND, WA 425-836-3333 DIMMITT BOOSTER STATION ELECTRICAL SYMBOLS AND ABBRIEVATIONS l)� Gr - j 5aU l �' 28947 s`S10 L EXPIRES 1/8/07 JOB NUMBER 03231.00 SHEET E -1 OF d O ova O � � 1 W