RESERVOIR SITE
0
NOTE: THAT PORTION OF THE
RESERVOIR SITE LYING WITHIN THE 7'
CHAIN LINK FENCE WAS N DT
ACCESSIBLE TO THE SURVEY CREW.
THE CONFIGURATION OF IMPROVEMENTS
WITHIN THE FENCE WAS DERIVED FROM
DRAWINGS OBTAINED FROM THE CITY
OF RENTON
0
ECO-BLOCK
WALL
Cj1L22304-9015
--,os
o ----\
122304-9016
U GT
\, I DEPICTS LI VIITS OF EASEMENT TO
SKYWAY WATER AND SEWER
DISTRICT.
LIMITS OF--EASEMFNT`
----- I_ _ —\ — PUMP
-,R- RELOCATE E_X S - _
_SCHOOL DIST. RADIO
8OX -TO -OTHER- -SID _
- - - - E F--DR!_VEWLY _ - ' —392_ _
/ —390�
CLEANOUT PER DETAIL - -
-- - --- __-SS12 (7YP11;�`L.OF-4__
_ 12" `
IE=383.2
12"CMP
°� ° j°°
IE=383.5
12"D.I,22" 1
/ �80 0 18130",(2)36" I
IE=382.1 30' BLACKBERRY
"GERRY
CUT INTO EXISTING
CITY OF RENTON 12" DI W/
1-12"x 12" TEE, FL x FL
3-12" G.V. FL x MJ
1-12"x 3' STERILE NIPPLE
1-12" SLEEVE
GRASS Ir 12 ,ONC
I
I
I
I
-CB RIM=403.51
IE 12" CONC(W)=401.8
10"
O
S. 12 6 T H S T. CONC CURB
6+62.9 1 6+00
Cn
I
W
I
CITY OF RENTON 12" TRANSMISSION MAIN (495 ZONE)
TO/FROM 460
ZONE & FROM CITY
OF SEATTLE
SOURCE OF WATER
I PIT3 I
31 20
D- 4
PIT1
o M3
tP4 P1 P2 P3
OM4
FCV1 I 1 1 1
PRV #7
SET 495
o M1 (NORMAL)
ADJACENT TO10-
SEND
OM2
—
PIT2
FUTURE 84TH AVE S.
I TRANSMISSION MAIN
-TO 84TH AVE S.
HOUSE NUMBER
FUTURE DI PIPE 8205
TO/FROM SKYWAY
TO 83RD AVE S.
DISTRIBUTION SYSTEM
(550 ZONE)
i
(550 ZONE)
1-12" 90'
BEND, RJxRJ
'
71 LF
i
SCHEMATIC PUMP
STATION
12" DIP
;
PIPING LAYOUT
2.0' MIN. 3.5' MAX
SCALE: NTS
TYP. ALL
_
ISEPARATION,
WATER MAINS SEE NOTE (4
a
1-12"x12" 45' BEND, RJxRJ
14 LF 12" D.I.
NORMAL OPERATION
2- BLOW OFF, DETAIL WA07
NOTES:
12 CAP, RJ
C11 Y OF SEATTLE TO SKYWAY 550 ZONE
1-12Mx12" TEE, FLxFL
OPEN O1 O3 ©
1, METERS 1, 2 & 4 SHALL BE ONE WAY METERS
2 12 GV, FLxMJ
CLOSED OZ 4 5
WHILE METER 3 SHALL BE CAPABLE OF
1-12" GV, FLxRJ
OPTIONAL
REGISTERING FLOW IN TWO DIRECTIONS.
11 LF 12" DIP, RJ
i 1-12" PLUG, MJ REMOVE EXIT
2. PRV #7 SHALL NORMALLY BE SET TO MAINTAIN A
TREE, 18"
ALTERNATIVE OPERATING
SCHEMES
495 ZONE ON THE DOWNSTREAM SIDE OF THE
LIMITS OF CONNECTION, SKYWAY
18 TESTING AND FLUSHING PER DETAIL
I 1] CITY OF RENTON 495 ZONE
TO SKYWAY 460 ZONE
VALVE. (WHEN 460 ZONE IS REQUIRED THE VALVE
WA 28 PRIOR TO CONN. TYP BOTH CON
OPEN 5002 QQ©
WILL NEED TO BE MANUALLY READJUSTED.)
122304-9075
CLOSED
3. ONLY MOTORIZED VALVES ARE SHOWN ON THIS
- -- S 8" ss
S SEE NOTE 4, NOTE 5
SCHEMATIC PLAN. SEE PUMP STATION FLOOR
PLAN FOR ISOLATION VALVES.
I oNN To
2� CITY OF RENTON 495 ZONE
TO SKYWAY 550 ZONE
2 _EXIST SSMH, _.
_ _ OPEN 5 2 O1 ©
4. WHEN PRESSURE FALLS IN THE 460 ZONE DUE TO
W GAS _ _ _ _ _ _ _
CLOSED 03 ®
INTERRUPTION OF SUPPLY OR HIGH DEMAND IN
REMOVE EXIST BLIND FL &
I
i
THE 550 ZONE, ADDITIONAL WATER WILL BE
USING
CONNECT TO EXISTINGS RIM=399.2f
OPTIONAL
SUPPLIED FROM THE CITY OF RENTON
8"x6" HYD. TEE W/ CL CHNL
I
ALTERNATIVE OPERATION SCHEME 1❑ WHILE NORMAL
_
8" ADAPTOR, FLxMJ8 Pvc(E)=391.Of
I
SKYWAY 460 ZONE TO RENTON 495 ZONE
OPERATION CONTINUES.
1 " "
s Pvc 1`„-�r`ml_111 1., . , %�. , . Q 8 x12 INCREASER, PExMJ
RICE PR ERN ` SIGHT FOR POWER LINE I 12" DI NIPPLE EXIST 15' SEWER OPEN O3 O1 O5
EASEMENT CLOSED 2 6 5. PRESSURE IN THE 460 ZONE VARIES BETWEEN
O 1" 1 OO HYDRAULIC GRADE LINE 450 AND 490. WHEN
w i I 15",(2)12 ,(2)20" 1 122304-9189
1 OPTIONAL - OPERATING UNDER SCHEME 1Q PRESSURE IN THE
460 ZONE WILL RISE TO 495.
NOTES ® SKYWAY 550 ZONE TO SKYWAY 460 ZONE
SYMBOL DESCRIPTION PUMP STATION SITE PLAN OPEN ©4 2 O3 6. M1, M2, M3, M4, PIT-1, PIT-2, PIT-3 FURNISHED
SCALE: 1 "-20' 1 5 BY SYSTEM INTEGRATOR, INSTALLATION BY
CLOSED
FOR THE CUT- N AT THE INTERSECTION OF 82ND AVE AND 126TH STREET, THE
5 EXIST COAXIAL CABLES ARE OWNED BY METROCALL WIRELESS. OO CONTRACTOR. SEE SPECIFICATIONS.
O O -
CONTRACTOR S-1ALL EXCAVATE, EXPOSE THE EXISTING 12 INCH PIPE AND PROVIDE COVER OVER EXISTING CABLES IS REPORTED TO BE LESS THAN 12". OPTIONAL
CABLES ARE TO BE RELOCATED BY UTILITY OWNER DURING 2ND
ALL NEEDED EQUIPMENT AND MATERIALS FOR THE WORK. THE ACTUAL CUT -IN WILL QUARTER OF 2005. PRIOR TO CABLE RELOCATION, CONTRACTOR TO SEE NOTE 2
BE PERFORMED BY CITY CREWS. CITY OF RENTON CREWS WILL CUT AND DRAIN THE TAKE MEASURES TO PROTECT CABLES DURING CONSTRUCTION.
EXISTING PIPE, INSTALL THE NEW TEE, PIPE, VALVES AND CONNECTING PIECES. CONTRACTOR TO COORDINATE WITH UTILITY OWNER BEFORE AND SKYWAY 550 ZONE TO CITY OF RENTON 495 ZONE
AFTER THE CITE CREW IS FINISHED, THE CONTRACTOR WILL POUR THE CONCRETE � 353002 DURING PERIOD THAT CABLES ARE BEING RELOCATED. NOTE THAT OPEN ©®O5
BLOCK, BACKFILL AND RESTORE THE SITE. CONTRACTOR TO NOTIFY THE CITY AT W
LEAST 72 HOURS IN ADVANCE OF THE PROPOSED CUT IN DATE. DESIGN GRADES SHOWN ON DRAWINGS CAN'T BE OBTAINED UNTIL CLOSED O2 Call
EXISTING CABLES HAVE BEEN RELOCATED. METROCALL CONTACT IS
O SAWCUT AND PATCH EXISTING PAVEMENT. SEE ELECTRICAL SITE PLAN FOR ADDITIONAL MIKE BELL, (206) 592-8154. Note: Cables relocated March 2005. OPTIONAL®O before you
PAVEMENT CUTTING AND PATCHING See Electrical sheets
SEE NOTE 2 D q g
O3 2-12" 22 1 /2- BEND, RJxRJ
04 RESTRAIN ALL JOINTS UNLESS 'DOTED OTHERWISE.
REVISION
P E
DATE BflAP An Engineering Services Company
Revd to reflect construction records March 2006
1601 2nd Avenue Suite 1000
Seattle, WA 98101
p. 206,441,1855 I f. 206.448.7167
......................................................
Civil Structural ( Planning I Survey
paceengrs.com
SKYWAY WATER AND SEWER DISTRICT DATE FEB. 2005
11909 RENTON AVENUE SOUTH DESIGNED BV
SEATTLE, WA. 98178 DRAFTED MTF
(206) 772-1580 CHECKED
1'=20'
1-800-424-5555
UNDERGROUND SERVICE (USA)
DIMMITT BOOSTER STATION
PUMP STATION SITE PLAN
jj_� , ", - � S ,-, --
JOB NUMBER
04192.00
P04192C-2 AB,DWG
SHEET C - 2 OF