Loading...
HomeMy WebLinkAboutWTR2703530.5CONCRETE PAD 6" THICK FITTING AND PIPE SCHEDULE W/ 6x6-W2.9xW2.9 WWF OVER 4" CRUSHED SYMBOL DESCRIPTION COMPACTED TO 95% 3 0 r N Q) a� 0 a EN 0 0 m i J m� N a UOaQ Pi tb 0 ..� w %o 00 N � a'c rQ �� m a0Mwa WN Li wwmw mmmQJ ZFFZ[Z Lq.<pww I-icaa-�Cn X O12w FLANGE COUPUI` G ADAPTOR 2� 12" DI PIPE, PE x FL (LENGTH AS REQUIRED) 3'-4" 8'-0" 1'-4" 2'-0" 3'-0" 8'-0" 3'-0" 2'-0" 2'-8" 3'-4" 6'-8" ROUGH OPENING ROUGH OPENING R.O.- INSTALL HOSE BIB QD 12" x 4" DI TEE, FL x FL 4" VENEER ON WALL 18" � 4 o 12» DI SPOOL. FL x FL (LENGTH AS REQUIRED) BLOCK, TY ABOVE GRATING O 5 6 x 4 ECCENTRIC REDUCER 176 O 10 DI SPOOL, FL x FL (LENGTH AS REQUIRED) 7 10 DI 90 BEND, FL x FL 7°-8"x8'-0" FLUSH PAIR STEEL DOOR ' ,- #_ » 3 Ox7 0 I I i i.:i. i 8 » 10 RESILIENT SEAT GATE VALVE W HANDWHEEL, FL x FL / .o � ! CONTROL FLUSH STEEL �'; � , ; . IL w _ REQUIRED iv CAULK AROUND 2x8 FRAME _ — ! PANEL ! DOOR ; ;- i I 5 19 (a6 ; 14 8 9 10 DI PIPE PE x FI. LENGTH AS ( ) + » .... F.F. EL. 399.40 8'-o"x8'-O" INSULATED L J 53 I ; ; 3 16 , e10 FLANGE COUPLING ADAPTER I ROLL UP DOOR. SEE -A 11 » �4 GALV. SHACKLE RODS, WASHER, NUTS AND # i� 60" x 84" MOTORIZED ALUM. LOUVER I 4 S-4 FOR REINFORCEMENT / OF OPENING IN MASONRY 40-B: C FIRE EXTINGUISHER MOUNT » W/ TOP 50 ABOVE FLOOR ----- THRUST RETENTION PLATE L ' � 12 o 12" x 10" DI 90' BEND FL x FL �- 12 8 1 WALL.. RECESS 2" EZ-ANGLE FULL i ;r 52) I LENGTH OF WALL. SEE I i - 18') 13 » 12 x 8 DI TEE, FL x FL 4'-3" 4'-2" 4'-3" I H I DETAIL 1 i I I ,.i . __ 1 .__. 14 8" DI SPOOL, FL x FL (LENGTH AS REQUIRED) w I ! F.F. EL. 399.40 S 2 i i , :I M3 � 3611 � 15 8" RESILIENT SEAT GATE VALVE W/ HANDWHEEL, FL x FL O Q U i FROM WALL FACE i 14 16 8" DI 90' BEND, FL x FL i Z 42 17 8" DI PIPE, FL x PE (LENGTH AS REQUIRED) O ! U W I ;i 44 1 x4 TRIM J 18 8" FLANGE COUPUNi� ADAPTER AROUND OPENING. O w 1 46 �19 8w BUTTERFLY VALVE W/ AUMA ELECTRIC ACTUATOR _ PAINT TO MATCH WALLS 0 w ! � (n CONCRETE PUMP PAD 55 34 " VENEER BLOCK 22 41 L WALL MOUNTED HEATER SEE ELECTRICAL DWGS (TYP OF 3) SUPPLY FAN LIMITS OF INTERIOR PIPING BID ITEM 20 12" BUTTERFLY VALVE W/ AUMA ELECTRIC ACTUATOR -o 0_ N 2x8 TREATED w iv ! 24 21 LINK SEAL PIPE SLEEVE FOR 12" DI PIPE, WS-16-37-8" FRAME FOR v) I 22 LINK SEAL, LS-325-C_ 54"x48" w- �� 0» _1 CONCRETE M4)T 17 cD ALUMINUM Y PUMP PAD E io A N C23 2400 GPM PACO HORIZONTAL SPLIT CASE DOUBLE LE LOUVER 0 SUCTION PUMP, 195 TDH, 200 HP 1770 RPM N z 1-300 GPM E 18 15 HP 6" DI DRAIN TO ° ° cr E SANITARY SEWER W/ 2" �24 PUMP PACKAGE, 3 -- 300 GPM PACO CLOSE COUPLE, END SUCTION Q VENT THRU ROOF BOOSTER PUMP SYSTEM 110 TDH, 15 HP, 3505 RPM, MODEL 23 i 11 i LL 1-300 GPM 2 25 ADJUSTABLE PIPE SUPPORTS, GRINNELL NO. 264 OR EQUAL \ CRANE RAIL 15 HP 0 PRV #7 O 9'f � (TYP BOTH � ■ SIDES) ° ° 59 w = SEE E3) 22" WIDE ALUMINUM 26 4 DIA. GLYCERINE FILLED PRESSURE GAUGE, PSI 0-160, NOSHOK » 26 23 0 5 SHIPS LADDER W/ SERIES 500 OR EQUAL W/ 1/2 BRASS BALL VALVE TAPPED INTO PIPE `t cn ,, � Q a 1-300 GPM � S-4 26 — 14 � HANDRAIL 27 8 PUMP CONTROL VALVE, CLA VAL MODEL 60 G 73 A B 16 35 a 58 15 HP 38 — 28 12" x 8" DI REDUCER, FL x FL 26 a 55 18 a 11 37 49 29 8" x 8" DI TEE, FL x FL AIR FLOW II 17 10 11 45 --I--- ---- ---- 30 8" x 4" DI 90' REDUCING BEND, FL x FL io R -- --- --- gin- 11 1 /2" COPPER 5 " ,� ; TUBING TO 52 1 1 I 31 4 SURGE ANTICIPATOR VALVE, CLA VAL MODEL 52 G 03-B, v ' u BOTTOM OF 9 11 42 �I 3 61 CRL 20-200 PSI, CRA 2-30 PSI 4 ao C PIPE CHASE 27 --- 32 4" DI 90' BEND, FL x FL FIXED ALUM. EXHAUST LOUVER 7 - - 33 4" DI SPOOL, FL x 11, LENGTH AS REQUIRED 32 15 V4" CO ----- O SENSING LINE 34 12" Cl FLOOR DRAIN W/P-TRAP & TRAP PRIMER, J R SMITH FIG. 2131 31 16 12 46 60 2 20 cnfE 13'-4" { --- O35 25 10" x 10" SUCTION DIFFUSER, FL x FL 0 - 36 8" MAG METER SUPPLIED BY TSI, INSTALL BY CONTRACTOR i_ 47 6 DI PIPE, FL x PE _ I 30 15 25 17 M 1 14 ! i F, ; I .' 6 " 37 4 DI PIPE, FL x PE 48 6" DI FLANGE COUPLING ADAPTER 6 _ �__ p0 o0R RP > 29 56 39 36 I I 28 2 40 3 M2 52 40 13 16 11 1) 20 22 38 6" DISMANTLING JOINT, ROMAC OR EQUAL 49 4" DI FLANGE COUPLING ADAPTOR �.•�5�-OpE ® IF 53 I I 53 O 39 8" DISMANTLING JOINT, ROMAC OR EQUAL 50 4" MAG METER SUPPLIED BY TSI, INSTALLED BY CONTRACTOR 40 12" DISMANTLING JOINT, ROMAC OR EQUAL 51 6" MAG METER SUPPLIED BY TSI,- INSTALLED BY CONTRACTOR 1 0 ��SEWER 6" DI DRAIN TO SANITARY w W T2 VEN THRUr I � x o" " S2 PRESSURE TRANSDUCER SUPPLIED BY TSI, INSTALL BY CONTRACTOR 4 -0 I I 300FOM _6 41 24 x 1 /2 .STEEL F LATE W/ UNIFLANGE 42 6" RESILIANT SEAT DATE VALVE W/ HANDWHEEL 53 REMOTE O METER, REGISTER MOUNTED 4't ABOVE FLOOR 24" SO. GRAVITY LOUVER 3"x3" ANGLE SEE C/S-2 43 6" Y-STRAINER 54 12m 11 1/4 DI BEND, RJ x RJ, W/ MEGALUGS - SEE SITE PLAN Call O 8" x 6" DI TEE, FL x FL 55 6" DI PIPE, FLxFL (1'-6" LONG WHERE ADJ TO M4) PUMP STATION FLOOR PLAN before you SCALE: 1 /2"=1'-0" D 45 8" x 6" DI REDUCER, FL x FL �cl SCHEDULE CONTINUES ON NEXT SHEET 46 6" x 6" DI 90', FL :c FL ELECTRICALLY ACTUATED VALVES �( ARE NUMBERED USING THIS SYMBOL 1601 2nd Avenue Suite 1000 Seattle, WA 98101 p. 206.441.1855 1 f. 206.448.7167 .. P,,i0=E Civil Structural Planning Survey SYM REVISION DATE BYI APP'D An Engineering Services Company naceengrs.com 1-800-424-5555 UNDERGROUND SERVICE (USA) 22 57 54 v 54 3'-0" SKYWAY WATER ' AND SEWER DISTRICT DATE FEB. 2005 DIMMITT BOOSTER STATION JOB NUMBER 11909 RENTON AVENUE SOUTH DESIGNED By 04192.00 SEATTLE, WA. 98178 DRAFTED MTF P04192-FLR-AB.DWG (206) 772-1580 CHECKED .� PUMP STATION FLOOR PLAN SHEET C-5 of SCALE 1 =20 y b o � o � N Y H (�