HomeMy WebLinkAboutSWP2703531.10of SECTION 32, TWP 24 N, R 5 E, W.M.
N
r
1-00
W
O
m
Q
w
w
O
Ln
f
a
W
z
J
U
H
Q
P "3
7
O 37338 W
rs1 �C I S T
�sSIONAL
a
W
z
J
w
W
H
z
W
U
3
0
LLI
LIJ
EXISTING FOG o
LINE z
z
G�A A
of ea
r� x
pp 38311 ,cy'w
.� �OISTES
�SS.1 NAL
4c�__"'4
-w ay & 0&b0x-ne, Ins
CONSULTING ENGINEERS
701 DEXTER AVENUE NORTH SUITE 200
SEATTLE, WASHINGTON 98109 (206) 284-0860
W
z
Q
J
W
0
W
W
z
0
W
m
11+
z
0
U gF1!NGTON BLVD_N• ---------------
0
J LgKE WA
J
ULj
_ _ _ REPLACE EX. CENTERLINE �jJ
tnX----__---
+ - 5 STRIPE WITH NEW RPMS AT w
-----
Q EXISTING FOG SAME LOCATION -
� REPLACE EX. CENTERLINE LINE
(A 14+00 _------_ O
5 STRIPE WITH NEW RPMS AT - O
SAME LOCATION 13+00
1:iL
Ln
12+00
Cn
RIGHT-OFf .•�- -WAY -------- W
----- - J
IL—w---- --------- _-----------_—" --
U)
+WO
U Q
�Q0
(n :2 J
W
C�
tZ'
m
z
0
W
a.
--_---_
w
U
Q
z
0
W
En
X
W
m W
U U
Q
mm
E
L
UTILITY NOTE:
THE CONTRACTOR SHALL CALL THE UTILITY LOCATION REQUEST CENTER
(ONE CALL CENTER; 1-800-424-5555) FOR FIELD LOCATION OF UTILITIES. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING
UTILITIES WITHIN THE PROJECT, WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE
UTILITIES AND SURVEYING THE VERTICAL AND HORIZONTAL LOCATION PRIOR TO CONSTRUCTION.
ALL POTENTIAL UTILITY CONFLICTS SHALL BE POTHOLED A MINIMUM OF FIVE WORKING DAYS IN
ADVANCE OF ANY PIPELINE TRENCH EXCAVATION. THE UTILITIES SHOWN ON THE PLANS ARE
BASED UPON AVAILABLE INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS OCCUR
THE CONTRACTOR SHALL CONSULT THE PROJECT ENGINEER TO RESOLVE THE PROBLEM PRIOR TO
PROCEEDING WITH CONSTRUCTION.
AS -BUILT SURVEY BY: EVAN
WAHLSTROM, PLS#44651
(INFORMED LAND SURVEY)
THE ORIGINAL PLANS WERE STAMPED
BY SC AND BB ON 2/14/2011 & 2/15/2011
NO.
SPEED
LIMIT
25
R2-1
a
W
REVISION
BY I DATE I APPR
REPLACE EX. WIDE EDGE LINE _
2 STRIPE WITH NEW STRIPE AT V
SAME LOCATION
Q
DESKM B.P.B.
DMM
C.J.K.
CHMK .
S.A.C.
+M.
B.P.B.
ONE RCH
AT FULL SMALE
IF NOT 011E NM
SCA E ABM MY
N
H
W
w
w
w
O
O
N
Q
H
U)
w
z_
J
2
CU
H
Q
GENERAL NOTES:
1. ALL SIGN TYPES, COLORS AND DIMENSIONS ARE
STANDARD PER THE MUTCD, UNLESS NOTED
OTHERWISE.
2. CONTRACTOR SHALL FURNISH AND INSTALL TEMPORARY
PAVEMENT MARKINGS IMMEDIATELY FOLLOWING PAVING.
3. SIGN SHEETING SHALL BE HIGH INTESNITY GRADE FOR
ALL NEW SIGNS.
CHANNELIZATION NOTES:
OCONTRACTOR SHALL FURNISH AND INSTALL PAINTED
DOUBLE YELLOW CENTERLINE STRIPE.
O CONTRACTOR SHALL FURNISH AND INSTALL PAINT
OCONTRACTOR SHALL FURNISH AND INSTALL 24" WIDE
PLASTIC STOP LINE PER RENTON STANDARD PLAN
H 008.
WIDE EDGE LINE.
Q
CONTRACTOR SHALL FURNISH AND INSTALL
PLASTIC
TRAFFIC ARROW PER RENTON STANDARD PLAN H008.
OCONTRACTOR
SHALL FURNISH AND INSTALL
TYPE 1
AND TYPE 2E RPM PER RENTON STANDARD
PLAN
H002 APPROACH LINE.
OCONTRACTOR
SHALL FURNISH AND INSTALL
TYPE 1
AND TYPE 2D RPM PER RENTON STANDARD
PLAN
H001 DOUBLE YELLOW CENTERLINE.
OCONTRACTOR
SHALL FURNISH AND INSTALL
PLASTIC
BICYCLE LANE SYMBOL PER WSDOT STANDARD
PLAN
M-9.50-01.
OCONTRACTOR SHALL PROTECT EXISTING STRIP AND
RPMS DURING CONSTRUCTION.
SIGNING NOTES:
Q CONTRACTOR SHALL FURNISH AND INSTALL NEW
SIGN(S)AND POST PER RENTON STANDARD PLANS.
CONTRACTOR SHALL SALVAGE SIGN TO THE CITY AND
WASTEHAUL POST/FOUNDATION.
AS -BUILT
mmmmmmmm
"°'" NO 1S3'101 CI TY OF 2/14/11
LAKE WASHINGTON BLVD NORTH Fes:
RENTON STORM WATER & WATER MAIN �:
DATUM DPAWM IMPROVEMENTS M
Public Works Dept. 19
CHANNELIZATION PLAN SHEETS �: OF.27
y
O
T�
y�
V
�yy
a�
�d
w
00
N
z
y