HomeMy WebLinkAboutSWP2703531.2T
LO
N
ABBREVIATIONS
AVE AVENUE
AC ASBESTOS CEMENT PIPE
ADJ ADJUST
ALT ALTERNATE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AP ANGLE POINT
ASPH ASPHALT
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS
ASSY ASSEMBLY
BF BLIND FLANGE
BLDG BUILDING
BLK BLOCK
BO BLOW OFF
BOP BEGINNING OF PAVEMENT
CTR CENTER
CAP CORRUGATED ALUMINUM PIPE
CB CATC H BAS I N
CENTER IRONLINE
CLR CLEARANCE
CMP CORRUGATED METAL PIPE
CO CLEANOUT
CONC CONCRETE
C CONDUIT
CONN CONNECTION
CONTR CONTRACTOR
CONT CONTINUOUS
CPEP CORRUGATED POLYETHYLENE PIPE
CPLG COUPLING
CY CUBIC YARD
CONT CONTINUED
CL CLASS
CF CUBIC FEET
CFS CUBIC FEET PER SECOND
ABBREVIATIONS
RED
REDUCER
REINF
REINFORCE
READ
REQUIRED
R W
RIGHT—OF—WAY
S
SLOPE
S
SOUTH
SCH
SCHEDULE
SF
SQUARE FEET
SFM
FOUND MONUMENT
SHT
SHEET
SPECS
SPECIFICATIONS
SQ
SQUARE
SSCO
SANITARY SEWER CLEANOUT
SSMH
SANITARY SEWER MANHOLE
SSNT
SET NAIL/TAG
SSRC
SET REBAR/CAP
STA
STATION
STD
STANDARD
TB
THRUST BLOCK
TC
TOP OF CURB
TEL
TELEPHONE
THRD
THREADED
THRU
THROUGH
TYP
TYPICAL
VERT
VERTICAL
W
WEST
W/
WITH
W/0
WITHOUT
WTR
WATER
SYMBOL LEGEND
DC DEGREE OF CURVATURE EXISTING
DI DUCTILE IRON
DIA DIAMETER
DOT DEPARTMENT OF TRANSPORTATION
DIM DIMENSION
DWGS DRAWING(S)
D
DRAIN
EOA
EDGE OF ASPHALT
E
EAST
EA
EACH
EL
ELEVATION
ELEC
ELECTRICAL
EOP
EDGE OF PAVEMENT
EXIST
EXISTING
F
FORCE MAIN
FIG
FIGURE
FIN
FINISHED
FL
FLANGE
FT
FEET
0
FIBER OPTIC
FOC
FACE OF CURB
GA
GAUGE
GALV
GALVANIZED
GI
GALVANIZED IRON
GV
GATE VALVE
HDPE
HIGH DENSITY POLYETHYLENE PIPE
ID
INSIDE DIAMETER
I
INVERT ELEVATION
NV
INVERT
N
INCH
LENGTH
LB
POUND
LF
LINEAR FEET
MAX
MAXIMUM
MFR
MANUFACTURER
MH
MANHOLE
MIN
MINIMUM
MJ
MECHANICAL JOINT
MISC
MISCELLANEOUS
N
NORTH
NO
NUMBER
NTS
NOT TO SCALE
OC
ON CENTER
OD
OUTSIDE DIAMETER
PI
POINT OF INTERSECTION
PP
POWER POLE
PVI
POINT OF VERTICAL INTERSECTION
PE
END
PERF
P RIFORATED
PVC
POLYVINYL CHLORIDE:
PVMT
PAVEMENT
PVT
POINT OF VERTICAL TANGENT
PC
POINT OF CURVATURE
PT
POINT OF TANGENCY
QTY
QUANTITY
R
RADIUS
RET
RETAINING
RR
RAILROAD
P.
of WAS
� �
x
�O
7338
ICI STE¢�
�sSI�NAL
p wW
1�
ANN
of WAS
AI
m � x
38311 q c i
S T % 1� ass f�NAL
c4CE5 >i
Crap ar Ombor xe, LmN
CONSULTING ENGINEERS
701 DEXTER AVENUE NORTH SUITE 200
SEATTLE, WASHINGTON 98109 (206) 284-0860
PROPOSED DESCRIPTION
11
i
110a
W
u
SURVEY AN
WAHLSTROM, PLS#44651
(INFORMED LAND SURVEY)
THE ORIGINAL PLANS WERE STAMPED
BY SC AND BB ON 2/14/2011 & 2/1512011
CURB & GUTTER
ASPHALT PAVEMENT
GRAVEL SURFACING
CONCRETE SURFACING
SECTION 32, TWP 24 N, R 5 E, W.M.
SYMBOL LEGEND
EXISTING PROPOSED DESCRIPTION
CONCRETE SIDEWALK (PERVIOUS CONCRETE/
CEMENT CONCRETE)
PAVEMENT GRINDING LIMITS
RIGHT—OF—WAY LINE
CENTERLINE OF ROADWAY
PROPERTY LINE
PERMANENT EASEMENT
LINE
TEMPORARY EASEMENT
LINE
CONTOUR LINE
BURIED CABLE TV
BURIED FIBER OPTIC
BURIED POWER
BURIED TELEPHONE
WATER MAIN (SIZE AS
NOTED)
GAS MAIN
IRRIGATION LINE
SANITARY SEWER
STORM DRAIN
SANITARY SEWER FORCE MAIN
DITCH
CULVERT (SIZE & TYPE AS NOTED)
FENCE (TYPE AS NOTED)
FENCE (WITH GATE)
TELEPHONE VAULT
POWER VAULT
TELEPHONE MANHOLE
NO. I REVISION
x
NOTED
QED
BY
MANHOLE OR DRYWELL (AS NOTED)
CLEANOUT
■ TYPE 1 CATCH BASIN OR CURB INLET
® TYPE 2 CATCH BASIN
POLE WITH GUY WIRE
POWER / TELEPHONE / GUY POLE
LUMINAIRE
YARD LIGHT
JUNCTION BOX (AS NOTED)
N GATE VALVE
BUTTERFLY VALVE
WATER METER
fi FIRE HYDRANT
REDUCER
THRUST BLOCK
TRANSITION COUPLING OR
FLANGE COUPLING ADAPTER
7 CAP/PLUG
T BLOW —OFF
AIR RELEASE VALVE
MAIL BOX (NOTED)
SIGN
TREE (CONIFER)
TREE (DECIDUOUS)
SHRUBS
BUILDINGS
ROCK WALL
ELEVATION POINT
MONUMENT
ANGLE POINT / CONTROL POINT
BENCH MARK
DETAIL NUMBER
1
REFERENCE SHEET
GEOTECHNICAL BOREHOLE
TOE OF FILL
F—EMBANKMENT
ONE a"
AT PJLL SCALE
F NOT ONE s1CH
SCALE ACCORDN8I.Y
va"Mm: Nmm lsee
r1oR MWA_ WD IW3/11s1
DATU M
GRADING QUANITIES
CUT: CIV56rc-y
FILL: 3A8(rcy 450q
GE CONSTRUCTION
ALL APE 2 CATCH BASINS AND ACCESS RISERS SHALL HAVE FLAT TOPS
2. LENGTHS OF PIPE AND INVERT ELEVATIONS ARE SHOWN AT CENTERLINE OF
STRUCTURE.
3. CONSTRUCTION WORK HOURS SHALL BE FROM 7:00 AM TO 5:00 PM, MONDAY
THROUGH FRIDAY UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS.
CONTRACTOR SHALL ABIDE BY THE CITY OF RENTON NOISE ORDINANCE.
4. LOCATE ALL CATCH BASIN AND MANHOLE FRAMES AND GRATES OUTSIDE OF
VEHICLE WHEEL PATH WHERE FEASIBLE (WHERE NOT FEASIBLE, INSTALL ROUND
COVERS).
5. ALL TYPE 1 AND 2 CATCH BASINS SHALL HAVE VANED GRATES EXCEPT WHERE
NOTED ON THE PLANS.
6. CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL PLAN FOR OWNER'S APPROVAL.
UTILITY NOTE:
THE CONTRACTOR SHALL CALL THE UTILITY LOCATION REQUEST CENTER
(ONE CALL CENTER; 1-800-424-5555) FOR FIELD LOCATION OF UTILITIES.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION,
DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WITHIN THE PROJECT,
WHETHER SHOWN ON THESE PLANS OR NOT, BY POTHOLING THE UTILITIES
AND SURVEYING THE VERTICAL AND HORIZONTAL LOCATION PRIOR TO
CONSTRUCTION. ALL POTENTIAL UTILITY CONFLICTS SHALL BE POTHOLED A
MINIMUM OF FIVE WORKING DAYS IN ADVANCE OF ANY PIPELINE TRENCH
EXCAVATION. THE UTILITIES SHOWN ON THE PLANS ARE BASED UPON
AVAILABLE INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS
OCCUR THE CONTRACTOR SHALL CONSULT THE PROJECT ENGINEER TO
RESOLVE THE PROBLEM PRIOR TO PROCEEDING WITH CONSTRUCTION.
CI TY OF
ML
RENTON
Public Works Dept.
AS -BUILT
D-353
LAKE WASHINGTON BLVD NORTH
STORM WATER & WATER MAIN
IMPROVEMENTS
SYMBOL LEGEND, ABBREVIATIONS
0 ti
i'..
2
2 27
o
y�
x
N � O
00
z
G�