Loading...
HomeMy WebLinkAboutTED4003545.1C' a o- LU C7 M Q o a D Ua ' A� O W a BLLJ c� Uj z n 17 17 �w N R-354501 i , r z O Lij Call 2 Working Days Before You Dig J 1=800=424=5555 Utilities Underground Location Center LU ID,MT,ND,OR,WA O CAUTION: U LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY LOCATION AND DEPTH OF UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION. SURVEY NOTE: LU EXISTING SURVEY FEATURES. BOUNDARY AND TOPOGRAPHIC DATA SHOWN ON THESE DRAWINGS HAS BEEN PREPARED, IN PART, BASED UPON INFORMATION FURNISHED BY OTHERS. WHILE THIS INFORMATION IS BELIEVED TO BE RELIABLE, J3ME CANNOT ENSURE THE ACCURACY AND THUS IS NOT RESPONSIBLE FOR HE ACCURACY OF THAT INFORMATION OR FOR ANY ERRORS OR OMISSIONS WHICH MAY HAVE BEEN INCORPORATED INTO THESE DRAWINGS AS A RESULT. CONCRETE INLET TOP 103.74± (MATCH FG) IE 100.74± r { r , EX. SDMH 48" TOP 100.7± 6" IE 98.90 (SW) EX. INLET_ 12" IE 98.75 (E) /TOP 100.0± 12" IE 98.70 (N) 6" IE 99.00 18" IE 96.25 (W) ° d Q ° . EX. FIRE Q - -- L 11 HYDRANT a---- --_ "" -� (j 50' CONCRETE EX. CB, TY E 1 _ TOP 100.7± SIDEWALK PLACE 6" EXTRUDED IE 97.75 { CONC. CURB WITH CONNECTTO EX. CB TAPERED END a CORE-DRIL OPENING & I PROVIDE V ATER TIGHT SEAL. CUFB& GUTTER 68' 12" SD @ 2% MIN. I TO BE REP -ACED PER CB-2 TYPE 1 v ! RENTON S C. PLAN F008. TOP 101.0 (MATCH FG) I, ! 1 cSe IE 98.03± EX� FIRE HYDRANT PER RENTON STD. a 1 I L 1Q, , TU PLAN 8012 (TYP.)37 l j �t 5i+ems^1.11 I 1 '0 LIJ1 ° i I 1-011 % z VZ� SDCO PER RENT0 STD. - PLAN B076.1 r L 5 6 W� of \ U , lb /ram 1 f r WHEEL 1 J00 STOP (TYP. i t; o I !f s W r 11 ,�49 d \\" CONCRE INLET �p TOP AO1.7 (MATCH FG) %� iE 98.7± _ , ful PER RAN N STD. d j PLAN.B01 (TYP.) 6" ROOF DRAIN @ 1 % MIN. r Q =I t 1a. L- -- ---- \7- -T t i r IMPERVIOUS AREA ANALYSIS: EXISTING SITE 6,929 SF (IMPERVIOUS) RE -DEVELOPED SITE 7,029 SF (IMPERVIOUS) PER CITY OF RENTON STORMWATER CODES, WATER QUALITY AND DETENTION ARE NOT REQUIRED. SINCE THE SITE IS RE -DEVELOPMENT POST FIRE, A STORMWATER REPORT HAS NOT BEEN PREPARED. INFORMATION PROVIDED IN THIS DESIGN REGARDING EXISTING CONDITIONS SUCH AS ELEVATIONS AND EXISTING FEATURES WAS PROVIDED BY RICHARD WYRICK, GENERAL CONTRACTOR. J3ME PROVIDES NO GUARANTEE OF THE ACCURACY OF SAID INFORMATION OR OUR INTERPRETATION AND USE OF IT. MODIFICATIONS AND ADDITIONAL INFORMATION HAVE BEEN ADDED THROUGH SITE RECONNAISANCE BY J3ME HOWEVER THIS INFORMATION IS NOT SURVEY ACCURATE, BUT IS PROVIDED AS A GENERAL GUIDE FOR CONSTRUCTION. THIS PLAN HAS BEEN PREPARED FOR THE SPECIFIC GRADING AND DRAINAGE SYSTEM MODIFICATION SHOWN AND MAY NOT BE USED FOR ANY OTHER PURPOSE. j G EX. FIRE HYDRANT 90, GRAPHIC SCALE 10 0 5 10 SCALE IN FEET 0 >� •!' /ter � r �r x �: ^ 0 vONTPACT1DN J IlNT N SI UE'NALK ONLY it rs !f EXPANSIO\ JONT N BOTH CCURR A\D SIDFWAi K r JO NT AND FIN SI I CFTHII SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS I. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. 2. ALL CONSTRUCTION SHALL. BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. 3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 8, GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES OVER AND UNDER PVC PIPE. 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 1-3. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS ADMINISTRATOR. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK 140 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTEC I PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA (APA). 19, BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE TI HELD WITH THE CITY OF RENTON, PUBLIC WORKS DESIGN ENGINEER. 20. ALL LIMITS OF CLEARING AND AREAS OF VEGETATION PRESERVATION AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY RAGGED IN THE FIELD AND OBSERVED DURING CONSTRUCTION. 21. AREQUIRED SEDIMENTATION/EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION ALL PRIOR TO LAND CLEARING AND/OR CONSTRUCTION TO ENSURE THAT SEDIMENT LADEN WATER DOES NOT ENTER THE NATURAL DRAINAGE SYSTEM. ALL EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME THAT CLEARING AND/OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITEE. 22. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONDITIONS DICTATE, THE PERMLTEE SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION ION CONTROL FACILITIES WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. 23. APPROVAL OF THIS PLAN IS FOR EROSION/SEDIMENTATION CONTROL ONLY. IT DOES NOT CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS, OR RETENTION FACILITIES. 24. DURING THE TIME PERIOD OF OCTOBER 1ST THROUGH APRIL 30TH, ALL PROJECT DISTRIBUTED SOIL AREAS GREATER THAN 5,000 SQUARE FEET, THAT ARE TO BE LEFT UN -WORKED FOR MORE THAN 12 HOURS, SHALL BE COVERED BY MULCH, SODDING OR PLASTIC COVERING. 25. IN ANY AREA WHICH HAS BEEN STRIPPED OF VEGETATION AND WHERE NO FURTHER WORK IS ANTICIPATED FOR A PERIOD 30 DAYS OR MORE, ALL DISTURBED AREAS MUST BE IMMEDIATELY STABILIZED WITH MULCHING, GRASS PLANTING OR OTHER APPROVED EROSION CONTROL TREATMENT APPLICABLE TO THE TIME OF YEAR. GRASS SEEDING ALONE WILL BE ACCEPTABLE ONLY DURING THE MONTHS OF APRIL THROUGH SEPTEMBER, INCLUSIVE. SEEDING MAY PROCEED, HOWEVER, WHENEVER IT IS IN THE INTEREST OF THE PFRMITEE, BUT MUST BE AUGMENTED WITH MULCHING, NETTING OR OTHER TREATMENT APPROVED BY THE CITY OF RENTON, OUTSIDE THE SPECIFIED TIME PERIOD. 26. FOR ALL EROSION/SEDIMENTATION CONTROL PONDS WHERE THE DEAD STORAGE DEPTH EXCEEDS 6 INCHES, A FENCE IS REQUIRED WITH A MINIMUM HEIGHT OF THREE (3) FEET, 3:1 SIDE SLOPES. 27. A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE, 24 FEET X 50 FEET X 8 INCHES OF 4 TO 6 INCH QUARRY SPALLS SHALL BE LOCATED AT ALL POINTS OF VEHICULAR INGRESS AND EGRESS TO THE CONSTRUCTION SITE. fr BROOMED FINISH 4° WICE. SMODT}- i'- -ROV51 FI'_ zFRIMFTFR r CENENT CONCRETE CURS i ZURB AND ^UTT=R SHOWV) hOT INCLUDED IN B1D ITEV t i /NE11 TH ST E y�cT w w z z 40 w NE 9 T_� ST 1 p SITE < o 0 � `c z z Y of hF > �NSyC w zw - m¢ a cn x O z 0 o N NE 4TH ST SS t3E 30.0 NOT TO SCALE LEGAL DESCRIPTION: RENTON HIGHLANDS #2 CORRECT PLAT LOT 2 RENTON SP 188 78 REC AF # 7808170836 SD PLAT DAF BLK 33 RENTON HIGHLANDS #2 CORRECTED PLAT TGW POR OF RENTON HIGHLANDS PLAT LY E OF E MGN OF H ST LESS POR OF SD BLK 33 DAF BEG NLY COR OF SD BLK 33 AT NXN OF SLY LN OF NE LOTH ST & SELY LN OF 20 FT PLANTING AREA ALG SE LN OF NE SUNSET BLVD TH S 35-41-33 W ALG SE LN OF SD PLANTING AREA 214.38 FT TO CRV TO RGT TH CONT ALG SD SE LN OF PLANTING STRIP & ALG CRV TO RGT WITH RAD OF 459.51 FT DIST OF 50.41 FT TH S 7-39-07 E 297.97 FT TH N 55-35-23 E 47.83 FT TH S 31-09-37 E 78.15 FT TH N 54-03-28 E 265.35 FT TH N 1-58-51 E 260.18 FT TAP ON SELY LN OF NE 10TH ST TH N 54-35-42 W 229.11 TO POB AND LESS POR OF SD BLK 33 DAF BEG AT NE COR OF SD BLK 33 TH NWLY ALG S MGN OF NE 10TH ST ON CRV TO RGT WITH RAID OF 930 FT DIST OF 212.93 FT TO POT TH N 54-35-42 W 32.07 FT TH S S-09-24 W 240 FT TH S 65-27-01 E 245 FT TAP ON WLY MGN OF J ST SD PT BEING 220 FT SLY OF NE COR SD BLK 33 TH N 2-51-18 E ALG SD WLY MGN 220 FT TO TPOB & LESS POR CONDEMNED IN KCSC CAUSE NO 744378 FOR ST PURPOSES DATUM: ASSUMED GENERAL NOTES: 0%VNER: DAVID AND CHRISTINA LAI 8933 SE 54TH STREET MERCER ISLAND, WA 98040 PROJECT MANAGER: RICHARD WYRICK 21320 11TH PLACE WEST LYNNWOOD, WA 98036 (425) 478-0355 Ci'AL ENGINEER: J3 MECUM ENGINEERING, INC. 1375 MALL STREET, SUITE 3 ISSACiUAH, WA 98027 (425) 313-1078 CONTACT: EDWARD MECUM, P.E. S1- -TION, TOWNSHIP & RANGE: NW 1/4, SEC. 9, T. 23N., R. 5E., W.M. K _. PARCEL NO. 722780 %-028 SITE AREA: 7,029 S1= SLOPE ROUNDINI VARIES (SEE COIQTRA_-) WII[PJ SPECIFIED ]3IDEV/A.LK MAY DC ADJACCNT IN CONTRAC- TO A WALL i SEE DETAIL) \� SIDEIVALI<. VARIES - 6' 0" PAIN. (SFFF CONTRACT) -HRR TINT i- NCLUDED BID ITEM / pia ` " 11 -�EMULUEU InINT Ell FIR CEMENT CONCRETE SIDEWALK ADJA-'E\T TC CURD CEMENT CONCRETE SIDEWALK C.O.R. DETAIL F005 NOT TO SCALE ,SHE. I OF OX P,-- 35►}5oi