Loading...
HomeMy WebLinkAboutWWP2703548.3BY MEANS OF A WYE AND 45°BEN➢. TWO W 45°BENDS SHALL NOT BE ACCEPTABLE. 0 4" CLEANOUT O 2 J Z J WYE WITh 45°13END AND PLUG. Z J U W 0 0 0 NOTES: of J HOUSE a. HOUSE & a HOUSE 0� a. HOUSE 1, Prior to installation of a sanitary sewer connection, a side -sewer permit must be purchased from the City of LL Renton Public Works Department, 2, Types of pipe and fittings that can be used for sanitary sewers shall be approved by the Department of Public Works, Rubber or neoprene gaskets as specified by the manufacturer, 4" SEWER PIPE (TYPICAL) 4" SURFACE r shall be used on joints, SEWER PIPE CLEANDUT WYE `4" 4" BEND AS REQUIRED (NO MORE a 3. A minimum grade of 2% (1/4" per foot) must be THAN 45 BEND). EVERY 2N0 \ 4" CLEANDUT h 4" SEWER PIPE, SEE NOTES 2 AND 3, maintained With 4' pipe, In the event a 2% grade z CHANGE IN DIRECTION OR GRADE WYE WITH PLUG WILL REQUIRE A SURFACE 3'-Q" MIN, MINIMUM LINE SIZE FOR OTHER THAN SINGLE FAMILY 1S 6" cannot be maintained. The owner must grant a O CLEANDUT WYE �4" TEST TEE WITH PLUG FACE UP grade release to the City and then can install ;o (TYPICAL) 6' pipe at a grade of 1%, i./') PROPERTY LINE PROPERTY LINE 4, For inspection of side sewer, call 24 hours z ID 6"x a" REDUCER 6' MIN. in advance, 277-5570. Site must be ready for inspection LLJ LO F:z L7 (TYPICAL) L7 L7 and representative on site when inspector LLJ arrives at appointed time. Side sewer and stub 12 shall be tested per City specifications, Q w w MAIN SEWER L]NE w w L w Make the connection at the house, Do not backfill Z the ditch until approval is given by the inspector. TYPICAL BUILDING SEWER INSTALLATION PLAN Final approval will be granted after the existing Useptic tank has been pumped out and filled with sand, LLJ o z 4" SOIL PIPE �� 5, IF THE BUILDING SEWER IS LOWER THAN THE Install side sewer with 2' minimum cover. 18" O LL_I m 4" CALDER COUPLING z ROADWAY ELEVATION, BACKFLOW PREVENTION cover Is allowed at the house If outlet Is shallow, C/) a o OR EQUAL TO FIT X DEVICE SHALL BE INSTALLED 2-84, EQUAL TO TYLER 6. If side sewer stub is not available, The owner shalt LD SURFACE CLEANDUT A be responsible for its installation. The side sewer a f- 4"x 4"14" WYE i s 4" CALDER COUPLING OR EQUAL TO FIT shall be a mlYllmUm Of 6' In size. If tee Is not N h available, the main sewer line must be tapped SURFACE CLEANDUT l-4"x thru a cast iron saddle. All work within 4"x4" WYE street right-of-way shall be done by a licensed 4" PIPING and bonded contractor, 4"x 4"x 4" TEST TEE �4" PIPING LLJFACE UP AND PLUGGED Z w 7. All work shall be accomplished In accordance w a 3 with the Washington Industrial Safety and N Z) u 4" NIPPLE j Health Act, (WISHA) W 13 z vw, f 6"x 4" REDUCER Pq J= 8, Alt trench backfill for side sewers in m Y� L7 z --6" COUPLING T❑ FIT END 6" PIPE the public right-of-way shall consist of 5/8' Q wo Q PLAN minus crushed rock. Q REMOVE 2"x4" STUD AND CAP OR PLUG �� i ON END OR EXISTING 6" SEWER PIPE, BUILDING DRAIN 9. All building sewer and side sewers shall have R_ AND INSTALL BUILDING SEWER COUPLINGS, REDUCER, TEES, AND BENDS AS REQUIRED. FOR LOW HOUSE bedding in accordance with drawing BW18C or IT, BR09 as applicable, PROPERTYI I LINE w SEE SIDE SEWER ➢ETAIL z 3LJ 6" PIPING TO 6-0" r H w N BEYOND PROPERTY LINE z ry 6" SIDE OUTLET TEE f o K a O N IL SEE NOTE 6 SEWER MAIN PLAN BUILDING SEWER INSTALLATION TYPICAL BUILDING SEWER SIDE SEWER (PROPERTY LINE) TO BLDG CONNECTION INSTALLATION PLAN NOT TO SCALE (C.O.R. STD. DETAIL BR35) W (SEE NOTE 4) LIMITS OF PIPE ZONE BACKFILL MATERIAL (SEE NOTE 5) 6 CONCRETE CLASS C i NOTES: (SEE NOTE 8) 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. C FOUNDATION LEVEL �� 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. \\\ f� i HAND TAMP ONLY. (CLASS A DESIGN) "EXCAVATION 4. SEE AND PREPARATION OF TRENCH" IN THE SANITARY SEWERS SECTION OF THE STANDARD SPECIFICTATIONS FOR TRENCH WIDTH "W" AND TRENCHING OPTIONS. THE PIPE ZONE WILL BE THE ACTUAL TRENCH WIDTH, EXCEPT FOR CLASS A BEDDING. THE MINIMUM CONCRETE WIDTH SHALL BE 1-1/2 I.D. + 18". — W (SEE NOTE 4) OF PIPE ZONE 5. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING SEWER TRENCHES" IN THE ,1/,-LIMITS SANITARY SEWERS SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS BACKFILL MATERIAL OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER SHALL NOT BE USED IN THE (SEE NOTE 5) 6" BACKFILL MATERIAL. BEDDING MATERIAL 6. SEE "BEDDING MATERIAL FOR RIGID PIPE" IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS FOR THE MATERIAL SPECIFICATIONS. FOR RIGID PIPE C (SEE NOTE 6) 7. SEE "BEDDING MATERIAL FOR FLEXIBLE PIPE" IN THE AGGREGATES SECTION OF B STANDARD SPECIFICATION FOR THE MATERIAL SPECIFICATIONS. FOUNDATION LEVEL 8. PIPE MUST BE ANCHORED IN SUCH A MANER AS TO ENSURE FLOW LINE IS A MAINTAINED. BEDDING MATERIAL FOR FLEXIBLE PIPE (SEE NOTE 7) FOUNDATION LEVEL (CLASS B, C, D, DESIGN) BEDDING FOR RIGID PIPE �-- W (SEE NOTE 4) (CLASS F DESIGN) BEDDING FOR FLEXIBLE PIPE IMITS OF PIPE ZONE _T 1 = O>> L BEDDING CLASS DESIGN DIMENSION CLASS A CLASS B CLASS C CLASS D CLASS F A 4" MIN. 1/4 I.D. 12" MAX. 6" MIN 6" MIN ZERO 6" MIN B 1/4 O.D. 1/2 O.D. 1/8 O.D. ZERO O.D. C 3/4 O.D. 1/2 O.D. 1/8 O.D. O.D. — PIPE BEDDING FOR SANITARY SEWER NOT 10 SCALE (C.O.R. STD. DETAIL B077) 11 SEAL WITH AR 4000 AND DRY SAND AFTER PATCHING PATCHED AREA A OUTSIDE DIA, 2" A.C. CLASS "G" 4" CONCRETE , - VI-.4 SECTION A -A PLAN REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS TWO FEET. ADJUST CASTING FRAME TO PAVEMENT SURFACE USING CONCRETE BLOCKS, REPLACE ALL BUT TOP 2" OF EXCAVATED MATERIAL WITH CLASS 3000 CONCRETE (3/4). FINISH PAVEMENT SURFACE WITH 2" OF A.C. CLASS "G", SEE CITY OF RENT❑N SUPPLEMENTAL SPECIFICATI❑NS SECTION 7-05.3(1), TYPICAL UTILITY COVER ADJUSTMENT FOR PAVEMENT OR OVERLAY NOT TO SCALE (C.O.R. STD. DETAIL BR36) R/W Ii- ---�_ _-.- F— ____ �_ CAP EXISTING SANITARY SEWER (REMOVE) EXISTING SIDE SEWER EXISTING G" SEWER A EQUIRFrI — STUB (REMOVE TO R/W)� _ V 6"x 4" REDUCER l \ 6" WYE 1/8 OR 1/16 BEND PROPOSED 6" SEWER STUB MAIN RUN SIZE X 6" TEE PROPOSED SEWER MAIN TYPICAL STUB CONNECTION FOR SEWER REPLACEMENT NOT TO SCALE (C.O.R. STD. DETAIL BR33) PROPERTY LINE 3'-0" MIN 6'-0" FUTURE G" BUILDING SEWER PIPE I BUILDING SEWER TEE WITH 6" SIDE OUTLET 6" SIDE SEWER AND BUILDING SEWER 1:3:5 MIX - CONCRETE BLOCKING _6" SIDE OUTLET TEE IN. SEWER MAIN F6" M CONCRETE BL❑CKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION 60" ALLOWABLE MAX, FOR CAST IRON PIPE OR DUCTILE IRON PIPE. ADJUSTING RINGS OR BLOCKS AS REQUIRED./72 24" - 24" x 6" FRAME AND LOCKING LID PER DRAWING BR29, 4" MIN. TO 12" MA PRECAST VALVE 7. ADAPTOR COLLAR CHAMBER CONE �. 8" OR 12" 16" R.C.P. OR EQUAL �� RUBBER GASKET PIPE 31" MIN. TO 48" MAX. h 5, D e D p. A A D ,, vn ° D D. G" MIN. W z 2"x 4" STUD SERVICE MARKER PAINT UPPER J PORTION WHITE ANS STENCIL ON SIDE WORDING 'SEWER" WITH 3" HIGH BLACK LETTERS, AND #6 WIRE WRAPPED AROUND THE STUD AND w EXTENDED TO THE TOP OF THE STUD, a 0 a UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN. VITRIFIED CLAY, PLAIN AND REINFORCED CONCRETE, D1 PIPE AND C1 PIPE SEWER MAINS ARE TO BE CORE DRILLED C�N 27. MIN SLOPE HORIZONTAL SEWER MAIN TYPICAL SIDE SEWER ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER, STANDARD SIDE SEWER INSTALLATION 5 REVISED PER CITY COMMENTS 4 REVISED PER CITY & OWNER COMMEN 3 REVISED PER CITY & OWNER COMMEN 2 REVISED PER CITY & OWNER COMMEN NO. I REVISION NOT TO SCALE (C.O.R. STD. DETAIL BR39) KAL 2 10 KAL suRl�° BILL SHIPLEY, PLS KAL 1 1 KAL DESIGNED: K. LITCHFIELD P.E. KAL KAL KAL 5 09 KAL Dom" I K. LITCHFIELD P.E. KAL 10 07 KAL I CHECKED: K. LITCHFIELD P.E. BY I DATE APPR I APPROVED: 1 " = 20' ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY 354803 VERTICAL: NAVD IM HORIZONTAL- NAD 1983/1991 DATUM /e1 48" POURED IN PLACE BASE -ALL 90'TLRNS SHALL BE ACCOMPLISHER SANITARY MANHOLE DETAIL EXTRA SHALLOW TYPE C NOT TO SCALE (C.O.R. STD. DETAIL BR39) 4— 1/2" WEB 8 PL. FRAME (NON -LOCKING) TYP. 5/8"-11 N.C. ON 2PL.)"B.C.(TYP, 3 PL.) FR 11G) — 23-1/4" — 33-1/4" — X J'- X J/b IVUN-JICIL -RN CAST INTEGRAL ON TOP COVER (N❑N-L❑CKING) FOR 5/8"-11 N,C, x 1-1/4" S,S. S❑C, HD. CAP SCREW (3 REQ'D.) TYP. N❑N-SKID PATTERN 0 7 o B 2" RAISED LETTERS AS REQ'D, SEE NOTE No,3 BELOW UNDERSIDE SHOWN FOR CLARITY 3/4" CORE (TYP,) ON 23" B,C. I-1/2" CORE(TYP.) (LOCKING) 1 �1-3/8" 1� 5/8" `3/8" �2„ 16 T 1" SEAT t ,- I— 2-1/2" 3/4" 25" - NOTES: 1, FOR N❑N-L❑CKING USE ❑LYMPIC FOUNDRY No, MH 30 OR EQUAL, 2, FOR L❑CKING LID USE ❑LYMPIC FOUNDRY No, MH 30 D/T OR EQUAL, 3, USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). MANHOLE FRAME AND COVER L 1 7' C 29176 NA ti~ STAMP NOT VALID UNLESS SIGNED AND DATED 4061 4`4R 1 CITY OF It- RENTON Planning/Building/Public Works Dept. NOT TO SCALE (C. O. R. STD. DETAIL BR29) LEADBErTER SFR SEWER EXTENSION NOTES AND DETAILS PAGE 1/2010 3 ur 3