R=25' MIN
M
FILTER FABRIC AS NECESSARY
4 TO 8 IN ROCK
12" DEPTH MIN
12 _►
CONSTRUCTION ENTRANCE DETAIL (TYP
SCALE: NTS
FILE: 8235C10-C-08
INSTALL TEMPORARY GRAVEL BEFORE
GRADING PHASE OF PROJECT,
REMOVE PRIOR TO PAVEMENT
INSTALLATION
zl�
NOTE: ONLY INSTALL
TEMPORARY GRAVEL AROUND
CATCH BASINS IN UNPAVED
AREAS. USE FILTER FABRIC TO
PROTECT EXISTING CATCH
BASINS IN PAVED AREAS.
INSTALL TEMPORARY FILTER FABRIC
BETWEEN FRAME AND GRATE OF ALL
CATCH BASINS AND INLETS INSIDE
OR ADJACENT TO DISTURBED AREAS.
8"
MIN.
PLAN
TEMPORARY CATCH BASIN PROTECTION
SCALE: NTS
FILE: 8235C10-C-08
APPROX LOCATION OF
CENTURY LINK 4" PVC
CONDUIT (LOOKING NORTH)
4" - 6" MOUND
UNDERGROUND WARNING TAPE
PER SUB -SECTION 10.15052
TRACER WIRE PER SUB -SECTION
10.15052
18" TOPSOIL STA 1+00 TO 8+60 T
(EXCLUDING STREAM CROSSING) ONLY. j
MATCH EXISTING GRADE. SEE I 15
SUB -SECTION 10.02900 FOR SALVAGE/
IMPORT REQUIREMENTS. BACKFILL FOR i I
ALL OTHER STATIONING AS INDICATED
ON THE DWGS AND AS SPECIFIED. i)
15" SS
NATIVE SOIL
TRENCH BACKFILL DETAIL I
SCALE: NTS
FILE: 8235C10-C-08
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED
IN PART ON INFORMATION PROVIDED BY OTHERS
THIS DRAWING SET WAS PREPARED ONLY FOR THE
PROJECT AND SITE SPECIFICALLY IDENTIFIED
HEREON AND IS NOT TO BE USED ELSEWHERE
Date
By iz/6/13
r ESA
—PER CITY STD PLAN 405 EXCEPT PIPE
ZONE MATERIAL SHALL BE GRAVEL
BACKFILL FOR PIPE ZONE BEDDING
PER WSDOT SECTION 9-03.12(3). IN NO
CASE SHALL PEA GRAVEL BE
PERMITTED.
TYP)
5309 Shilshole Ave. NW
Seattle, WA 98107
P: (206) 789-9658
F: (206) 789-9684
BURIED UTILITIES IN AREA
PLEASE CALL BEFORE YOU DIG
1.800.424.5555
2"
ST
OF
0
Lo
FILTER FABRIC MATERIAL 60" WIDE
Rni.LS. USE STAPLES OR WIRE
GS TO ATTACH FABRIC TO WIRE
3Y 2" BY 14 GA. WIRE
3RIC OR EQUIV.
FILTER FABRIC
MATERIAL
4 2" BY 2" BY 14 GA. WIRE
FABRIC OR EQUIV.
8" '►
MIN
MR
CV Z N
g
0
10
BURY BOTTOM OF �2" BY 4" WOOD POST
FILTER MATERIAL IN
8" BY 12" TRENCH
Stu i iON
NOTE: FILTER FABRIC FENCES SHALL BE INSPECTED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING
PROLONGED RAINFALL. ANY REQUIRED REPAIRS SHALL BE MADE IMMEDIATELY.
K*�2 SILT FENCE DETAIL
C-02 SCALE: NTS
FILE: 8235C10-C-08
SACKS SHALL BE #10 JUTE BURLAP
OR APPROVED ALTERNATE FILLED
WITH 48 TO 55 LBS. OF PEA GRAVEL
BACKFILL DR DRAINS
INSTALL APPROXIMATELY 3 FEET
ABOVE CHANNEL INVERT. ALIGN
LOW POINT IN DAM WITH CENTER
OF CHANNEL.
ADD VISQUEEN
THROUGH FILLED
BURLAP SACK STACK
PLACE SACKS FIRMLY
AGAINST GROUND LINE
AND ADJACENT SACKS.
PLAN
SECTION A
FLOWLINE
STREAM DEWATERING COFFERDAM DETAIL I
SCALE: NTS
FILE: 8235C10-C-08
INSTALL NATIVE STREAMBED MATERIAL WHERE
SUITABLE OTHERWISE PROVIDE STREAMBED
SEDIMENT PER WSDOT SECT
DEPTH OF 12". MATCH EXIST
APPROX LOCATION OF
CENTURY LINK 4" PVC
CONDUIT (LOOKING NORTH)
TRENCH
SCALE: NTS
FILE: 8235C10-C-08
CLSM PEI
SECTION
NATIVE Si
TYP
UNDERGROUND WARNING TAPE
PER SUB -SECTION 10.15052
TRACER WIRE PER SUB -SECTION
10.15052
BACKFILL ONLY
BACKFILL AT STREAM CROSSING DETAIL
J: oAda PWA#ft lf#AV%
KEY NOTES:
OTHE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE BARRIER TO AVOID USE OF
JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST, WITH A
MINIMUM 6-INCH OVERLAP, AND BOTH ENDS SECURELY FASTENED TO THE POST.
OTHE FILTER FABRIC FENCE SHALL BE INSTALLED TO FOLLOW THE CONTOURS (WHERE FEASIBLE). THE FENCE POSTS SHALL
BE SPACED A MAXIMUM OF 6 FEET APART AND DRIVEN SECURELY INTO THE GROUND (MINIMUM OF 30 INCHES).
OA TRENCH SHALL BE EXCAVATED, ROUGHLY 8 INCHES WIDE AND 12 INCHES DEEP, UPSLOPE AND ADJACENT TO THE WOOD
POST TO ALLOW THE FILTER FABRIC TO BE BURIED.
O4 WHEN STANDARD STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO
THE UPSLOPE SIDE OF THE POSTS USING HEAVY-DUTY WIRE STAPLES AT LEAST 1 INCH LONG, TIE WIRES OR HOG RINGS.
THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF 4 INCHES AND SHALL NOT EXTEND MORE THAN 36 INCHES
ABOVE THE ORIGINAL GROUND SURFACE.
O5 THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED THE FENCE, AND 20 INCHES OF THE FABRIC SHALL
BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN 36 INCHES ABOVE THE ORIGINAL GROUND
SURFACE. FILTER FABRIC SHALL NOT BE STAPLED TO EXISTING TREES.
OWHEN EXTRA -STRENGTH FILTER FABRIC AND CLOSER POST SPACING ARE USED, THE WIRE MESH SUPPORT FENCE MAY BE
ELIMINATED. IN SUCH A CASE, THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE POSTS.
O7 PROVIDE 3/4"-1.5" WASHED GRAVEL BACKFILL IN TRENCH AND ON BOTH SIDES OF FILTER FENCE FABRIC ON THE SURFACE.
OINSTALL UPSTREAM SCREENED DIVERSION PUMP. PUMP SHALL, AT A MINIMUM, BE A 6 INCH GAS POWERED TRASH PUMP,
SUFFICIENT TO HANDLE EXPECTED STREAM FLOWS OF 0.5 TO 3 CUBIC FEET PER SECOND INCLUDING FLEXIBLE PIPE
SYSTEM.
OSELECT DISCHARGE POINT DOWNSTREAM OF IMPACTED AREA TO AVOID EROSION. LINE DISCHARGE AREA WITH VISQUEEN
OR EQUIVALENT TO DISSIPATE FLOW ENERGY AND PREVENT CHANNEL SCOUR.
10 INSTALL UPSTREAM COFFERDAM WITH LOW POINT ALIGNED WITH CENTER OF ACTIVE CHANNEL. COORD LOCATION WITH
TEMPORARY STREAM CROSSING.
11 INSTALL DOWNSTREAM COFFERDAM BELOW IMPACTED AREA.
12 COMPLETE ALL IN WATER WORK, GRADE SITE AND INSTALL COIR LOGS AND COIR BLANKET WHILE CHANNEL IS
DE -WATERED. WORK SHALL BE COMPLETED AFTER INSTALLATION OF PIPELINE AND DURING REMOVAL OF TEMPORARY
STREAM CROSSING. DECOMMISSION BYPASS PUMPING SYSTEM UPON ACCEPTANCE BY OWNERS REPRESENTATIVE.
13 WHERE DEWATERING PIPE CROSSES EQUIPMENT CROSSING OR INTERFERES WITH CONSTRUCTION, BURY PIPE IN A
TRENCH AND COVER WITH STEEL PLATES.
14 USE HIGH VISIBILITY FENCING TO DELINEATE IN -STREAM LIMIT OF WORK.
15 BACKFILL AS INDICATED ON PIPING PLAN AND PROFILE SHEETS.
z
0
4
10 _ 14
8
i
i
4 12
11
9 13
14
TY P
A STREAM DEWATERING PLAN
SCALE: 1" = 10'-0"
FILE: 8235C00-C-100
S 0354910