Loading...
HomeMy WebLinkAboutWWP2703556.13 0 0 0 CV z 0 0 w > c 0 N Li a z 0 3-23-5 510 500 50 0 50 100 SCALE IN FEET Ed Loll] �— G. �EX wV EX = = I I .12' CONC EXEX 14'CULV METAL EX.WM I DATUM: NAVD 88 SITE BENCH MARK EX. NAIL & ALUMINUM SHINER B.M. ELEV. = 508.37' _ EX. 12"DI W =w= _ _ =w= — =w= o —W — �--Ex.12" CMP G G G— PROPOSED CURB, SIDEWALK11 a IrcH �SPHALr .I 13' 3 1 ERM. ES T 1 EXISTING REBAR/CAP PLANTER STRIP & DRIVEWAY — D _ 2"FI I rcuizo AT THE PROPERTY CONER ( ) � TYP. EX. SEPTIC S --PROPOSED W I- 1 II I I I I I II II II II II I II II I� I I< B�UJ � I N Q V) WI X 01 w X W QI SWALE I L AND DRAINAGE FI D I I 1 0223 CA PORT ir L — — — — EX. HOUSE L _ CO ( P PROPOSED > EX. HOUSE I ABANDONED 8^pl yy � J I 1DT EX. HOME —� Q of H W #11 811 (TO REMAIN) of I = L-�� ----J PA DC I _ I I 1— _ 6" PVC S.S. STUB (F.F. - 510.3') w � oil 00 S X. B" 01 QQCyG ,pATJO EX 6 � I I I r D CHAIN UNK r'— CE 5' TYP. TR 0 30 x 5x 6 SERVE MH 1202-3 FH M 6 xl( B Q � MH 1202-2 EX. RAILROAD TIE i PR0 S A E EX. 12" CU RETAINING 2' WALL ME AL 1 O'TYP. PROPOSED PARKING (TYP.) 10' PER ESMT._— EX' SATE I —EX. 14" METAL CULV. EXIST. DRIVEWAY 3(TO BE CLOSED) 3-23- 5 II 15' PE_RM. E M. 14 n I I I C1043 Proposed Q wl 1 I ONSITE ESMT. CHURCH 11 -� MAINTAIN 5' MIN. II I II Ii t ( F.F. = 510.6' )115 I WATER / SEWER (FUTURE I Ex. SEPARATION (TYP.) EXPANSION (EXISTING 16'C I TR 0+39 — — BUILDING) 5X 10X@ I MH 1202-1 MH STUB Ln 0020X3 xC.O.x@ EX. GRAVEL ROADWAY EX. WIRE FENCE E T EE I — 0021 TO REMAIN4 CRD SHEET 1 Of 1 SERVE 0221 0222 EXISTING REBAR/CAP 1 rl I AT THE PROPERTY CORNER 6' WOOD FENCE 15' PERM. ESMT. ' I HAN NGUYEN r----------------- 8F I 1 NOTE: 0 33-23- 5 ; 20' TEMP. CONST. PERMIT 1 o FR CONSTRUCT 6 SEWER STUB SERVICE @ 2 /o 1EX. HOUSE #18833 I TL 1 04 10 FIR 1 ( MIN. LINE & GRADE. LOCATION SHALL FIT 0065 C1044 �® E_NTR_Y_LNO_BASEMEN_�; 5x�7 8"F I BUILDING S.S. OUTLET. THIS 6" STUB SERVICE OFFSITE ESMT. & PERMIT 1 I I SHALL BE OWNED & MAINTAINED BY THE REC. # 20100618000078 0% 8"SP I PROPERTY OWNER. PROVIDE CLEANOUT w/ SERVE I I i up LOCKING LID AT 5' MIN. AWAY FROM BUILDING MARION LEROY KELLY 20' TEMP. CONST. PERMIT PER DETAIL S-30. SURFACE CLEANOUT TO BE 33-23- 5 ' -----� 15"PI I INSTALLED DURING THE S.S. STUB 'S»L 15' PERM. ESMT. I CONNECTION TO THE BUILDING. 0066 C1045 z"cE I I I OFFSITE ESMT. & PERMIT i SERVE, 2"cE I I I 6' WOOD REC. # 20100618000077 EX. HOUSE #18839 I EX. GR. RW i I I EX.MH 1087-13 EX.SHEDL i ® GARAGE (NO BASEMENT) L--------- I x 6XV EX. 's I - -} — — — -EX. 8"DI W— — —� �T� EX-MH 087-12 T'� - SERVED I 246 3 -23- 5 10'TYP. 114 7 SERVED I S1028 E . 15' PERM. SMT. I EX.MH I\\ 0804070012 6 o SE 189TH L. LU ii I 22 > I I' r I 1 14 (5 ii I ( ii w 1 III III 0 I� — 1 z 24 II I III I EX.FH (D 1 9 10 11 . f�• II II t u I I II // X.MH 1087-10 I 1 *-EX.MH 10 7-6 89 H P I ;, , I EX.WV's --- I Ex.wv's-------- I- — — � � TRACT 'B' ' :X. 8"DI w — —--— ----- — -. _ EX ---- -- ----------------- _---------------------------- — EX.FH �S r-------1 I I "r- o I APPROX. EX. 3 3 GARAGE I w TR 0+87 x 1 OxTx10xT7 -- 1O'TYP. 0243 0247 -- SERVE ' o 3 ----------� I APPROX. I i I EX. HOUSE X i #18838 w a I FF=510.4t 0 \ ore 5 G VEL DRIVE UP ------EXISTING REBAR/CAP X. 6' w000 AT THE PROPERTY CORNER — 5' --EX. 8"DI W �-EX. 8" SAN. SEWER (TYP.) EX-MH 1087-11 SF'Q1iF 0260 SFR�F II EX.FH — — — _ EX1v S EX.j1 2"DI W — —11 —W— — —w— X., V's I I Ljj � II II II Q �I 04 �I � II �I 5-355601 NOTE: TYPICAL ALL SIDE SEWER STUBS. • SCWS DISTRICT OWNERSHIP TERMINATES AT PROPERTY LINE. • INSTALL TEST TEE AT PROPERTY / EASEMENT LINE. • DEVELOPER CONTRACTOR MAY EXTEND BEYOND PROPERTY LINE. (SEE STUB SERVICE CONSTRUCTION DETAIL.) SEWER GENERAL NOTES" (REVISED09/26/01) 1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE SPECIFICATIONS OF SODS CREEK WATER AND SEWER DISTRICT, ALSO REFERRED TO HEREINAFTER AS "DISTRICT". 2. THE DEVELOPER SHALL FURNISH THE DISTRICT A COPY OF THE COMMERCIAL AND/OR SUBDIVISION PLANS APPROVED BY THE GOVERNING AGENCY PRIOR TO ANY SEWER MAIN CONSTRUCTION. 3. PRIOR TO CONSTRUCTING ANY SEWER MAINS, THE APPROPRIATE STREETS AND LOTS SHALL BE CLEARED, GRADED, AND STAKED BY THE DEVELOPER AND ALL EXISTING UTILITIES SHALL BE LOCATED BY THE CONTRACTOR. 4. FOLLOWING SEWER MAIN CONSTRUCTION, ANY REVISION OF ROADWAY OR EASEMENT GRADES REQUIRING THE MAINS TO BE RECONSTRUCTED SHALL BE MADE AT THE DEVELOPER'S EXPENSE. RECONSTRUCTION SHALL CONFORM TO THE SPECIFICATIONS OF THE DISTRICT. ALL COSTS FOR INSPECTING SUCH RECONSTRUCTION SHALL BE CHARGED TO THE DEVELOPER IN ADDITION TO THE STANDARD CHARGES, AND SHALL BE PAID BEFORE ACCEPTANCE BY THE DISTRICT. 5. NO SIDE SEWER CONNECTIONS SHALL BE MADE TO THE EXISTING SYSTEM UNTIL COMPLETION OF THE BILL OF SALE AND ALL EASEMENTS. OBTAIN SIDE SEWER PERMIT FORM SOOS CREEK WATER AND SEWER DISTRICT FOR EACH SIDE SEWER CONNECTION PRIOR TO MAKING CONNECTION. BILL OF SALE WILL NOT BE PROCESSED UNTIL PUGET SOUND ENERGY HAS INSTALLED THEIR VAULTS, HAND HOLES AND LIGHT STANDARDS. 6. ALL COSTS OF SEWER MAIN RE -STAKING SHALL BE PAID BY THE DEVELOPER. 7. PROPERTY CORNERS SHALL BE PINNED WITH REFERENCE TACK ON CURBS BY THE DEVELOPER. 8. CONTRACTOR SHALL NOTIFY SOOS CREEK WATER AND SEWER DISTRICT AT (253) 630-9900 TO SCHEDULE A PRE -CONSTRUCTION MEETING AT THE DISTRICT OFFICE. AFTER THE PRE -CONSTRUCTION MEETING THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION REVIEW REPRESENTATIVE FOR SOOS CREEK WATER AND SEWER DISTRICT AT LEAST 48 HOURS (REGULAR WORKING DAYS) BEFORE STARTING WORK. 9. CONTRACTOR SHALL OBTAIN ALL REQUIRED FINAL INSPECTIONS TO MEET PERMIT REQUIREMENTS. INSPECTIONS MUST BE SCHEDULED AT LEAST 48 HOURS IN ADVANCE. NOTES RELATIVE TO CONNECTION TO EXISTING FACILITIES: 1. CONNECTION TO EXISTING LINE SHALL BE MADE ONLY WITH THE WRITTEN APPROVAL OF SOOS CREEK WATER AND SEWER DISTRICT. 48 HOURS (TWO REGULAR WORKING DAYS) ADVANCE NOTICE MUST BE GIVEN. 2. EXISTING SEWERS TO REMAIN IN SERVICE AT ALL TIMES. 3. ALL WATER AND/OR CONSTRUCTION DEBRIS SHALL BE REMOVED FROM NEW SEWERS AND SHALL NOT BE PERMITTED TO ENTER THE EXISTING SYSTEM. 4. EXISTING MANHOLE NO.1087-12 SHALL BE CORE DRILLED AND RE -CHANNELED AS REQUIRED TO RECEIVE INCOMING FLOW FROM THE NEW SEWER LINE. w co LLi Tn W 00 SIR P u —3o�� 39406 ISTEgF,� W �ssIONAL FOR CONSTRUCTION RECORDS DRAWING ONLY REVISED TO INDICATE CONSTRUCTION RECORDS FIELD REP: KEN HAINES REVISED BY: IZABELLA MIROCHNIK DATE: JANUARY 3, 2011 wv� C01"TRACTOR: GREEN EARTH ENTERPRIZES 6"PVC PIPE: 54 L.F. SDR35/ VINYL TECH. 8"PVC PIPE: 459 L.F. SDR35/ VINYL TECH. MANHOLES: 3-48" CONCRETE/QUALITY SERVICES: 2-ONSITE, 5-OFFSITE ORIGINAL DRAWINGS: SHEETS 2, 3 AND 4 NOT A PART OF CRD SET. CRD SHEET 1 OF 1 176TH ST SE 186TH SE 156TH ST SE 14rH ST IIIcn w W CN Q SE 186TH ST > 0 Q Z SE 188TH ST co 189 H PROJEC_ L SE 191 ST 0 SE 192ND ST W U) w a VICINITY MAP 0 N 1 4N Q o rn Wz 14 o a 0 U m Q Q-j z o 0 O UO w m O Q a Q O � U U o � co J W z = o Y G t 2 a LO a) Q Q' U w CID CID LO cn O 0 oco (D v U 2 a CD a)z CL N m FCID LL ao � � Y .o (Do U CO � Q w o ° a c w 0 oLO I� �I L o w N ... 0 U O W �-UO=� z z Q cn U w w O J LL X O W C) Z W W O z NJ g U3:�U)z Q s..C/)W Otn WSJ wo � 06 U) N. U) I-- BASE MAP E-4 SHEET 'I OF 4 DRAWING B-261 SCANNED APR 0 2 2011