HomeMy WebLinkAboutWWP2703557.14ILZ
O
Z
0 V 2' 3'
PEEG002
f TYPI
j
ool
ANTENNA1
FROM
ELECTRICAL
CABINET
SEE DWG
C-03
LL
w
x
x
N
a�
6
w
E
0
N
T
N
CV
�— X X
5 • �—
t i
314" RCS CONDUIT MIN.
SEE E-01 FOR $l s ,
CONTUCTOR I•
ZSO PUMP NO. 2 CHECK VALVE
02 LIMIT SWITCH
.A — X
m..m m.,m 1 I'
REQUIREMENTS LSH I I I. '.A
02 1 I -.
•
NL1031 VALVE VAULT I I
Typ FLOOD SWITCH
3 RTUI CONTROL PANEL . ' VALVE
VAULT
PUMP- CONTROL PANEL : s I SUMP PUMP
EM015 EM801 ZSO 10 I SP-01
PUMP RECEPTACLE MUST BE TYP (TYP.) VAULT HATCH TYP 03
ABLE TO FIT THROUGH OPENING INTRUSION SWITCH
FOR PUMP REMOVAL. -
�— t XP
1 '
EM108
TYP
PMP-02 PUMP NO. 2
PMP-04 PUMP NO. 1 ZSO PUMP NO. 1 CHECK VALVE
01 _LIMIT- SWITCH
J,
AB-01
AS BUILT
PHOTO
LEVEL
SWITCHES
01 SECOND CONDUIT
BEYOND THIS VIEW.
LSL
01
1 KELLEMS GRIP (TYP.)
LSLL
01 PROVIDE J-HOOK AND
KELLEMS GRIP TO MOUNT
NEW LEVEL TRANSMITTER
SUBMERSIBLE AND LEVEL SWITCHES.
LEVEL
TRANSMITTER PROVIDE STAINLESS
LT STEEL C-CHANNEL AND
01 MOUNTING HARDWARE
PROVIDE A J-HOOK AND A
a i CORD WEIGHT FOR EACH
FLOAT.
EM801
ZSO WET WELL
04 TYp INTRUSION SWITCH LEVEL TRANSMITTER
MOUNTED IN SCH80 - r
PVC STILLING WELL.
COORDINATE STILLING I'
WELL DIAMETER WITH - I?
LEVEL TRANSMITTER
MANUFACTURER.
)ELECTRICAL SITE PLAN
SCALE- 3/4" = V-0"
FILE: 8235B-ELEC SRV.DWG
RECORD DRAWING S =3557 14
THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED
IN PART ON INFORMATION PROVIDED BY OTHERS
THIS DRAWING WAS PREPARED ONLY FOR THE k«
PROJECT AND SITE SPECIFICALLY IDENTIFIED ORIGINAL
HEREON AND IS NOT TO BE USED ELSEWHERE STAMPED BY 1-REGORD DRANA
AV% % % ADAM LLOYD OLEARY
Date Z/ 8 / 2� 2 9110/20-10
n 46679
ByNO.
LT
01
3 WET- WELL S
- SCALE: NTS - -
FILE:-8235B10-M-301.DWG
(N) CONDUIT
TRENCH
NEW SIX INCH -
CONDUIT (TYP. 2)f
9
KEY NOTES:
1�
INSIDE OF WET WELL IS A CLASSIFIED AREA. EXTENT OF AREA
CLASSIFICATION AS FOLLOWS:
(a -}INTERIOR OF WET WELL IS CLASS I, DIV 1.
(b)ENVELOPE 18" ABOVE TOP OF THE WET WELL AND
TRENCH EXTENDING 36" BEYOND EXTERIOR WALL OF
EACH IS CLASS I, DIV 2.
(c)ELECTRICAL INSTALLATION IN THESE LIMITS SHALL
MEET ALL REQUIREMENT FOR CLASS t, DIV 1 AND DIV 2-
----~
LOCATIONS. ALL CONDUITS ENTERING OR LEAVING THIS
AREA SHALL BE INSTALLED WITH CONDUIT SEALS.
HEATED
ENCLOSURE.
O
INSIDE OF VALVE VAULT IS A CLASSIFIED AREA. EXTENT OF
AREA CLASSIFICATION AS FOLLOWS:
(a)INTERIOR OF VALVE VAULT IS CLASS I, DIV 2.
(b)ELECTRICAL INSTALLATION IN THESE LIMITS SHALL
MEET ALL REQUIREMENT FOR CLASS I, DIV 2 LOCATIONS.
ALL CONDUITS ENTERING OR LEAVING THIS AREA SHALL
BE INSTALLED WITH CONDUIT SEALS.
3
CONTRACTOR TO INSTALL OWNER PROVIDED RTU PANEL.
/
4
PROVIDE SUN SHIELD FOR THE PUMP CONTROL PANEL AND
OWNER FURNISHED RTU PANEL.
OEMPTY
COMMUNICATION CONDUIT INSTALLED FOR RENTON
INFORMATION TECHNOLOGY DIVISION.
WP CONVENIENCE
RECEPTACLE _
L=l
' LSHH
m
01
LIFT PUMP RECEPTACLES,
o
'
MUST BE ABLE TO FIT
THROUGH OPENING FOR
n
PUMP REMOVAL.
LSLL•
BOTTOM OF RECEPTACLE
01
PCS CONDUIT UNBROKEN
FROM 18" ABOVE GRADE
LSLL
_ TO 6" BELOW GRADE.
01
KELLEMS GRIP (TYP}
z
2 PUMP SIGNAL CABLE
PUMP- POWER CABLE
NEW CONDUIT
TO HEATED <
ENCLOSURE
TRANSMITTER
NEW CONDUIT TO
STONCO GP2 175W
METAL HALIDE VANDAL
RESISTANT FLOOD LIGHT
MOUNTEQON SWIVEL -
BASE.
PUMP
CONTROL
PANEL
PER
SUB -SECTION
10.11311
LEVEL SWITCH
CABLES
EM230 w
TYP -
(NTS)
MOUNTING METER AND TRANSFER L
SHOWN OUT OF
SECTION SWITCH CABINET
FOR CLARITY NEW CONDUIT
TO VALVE VAULT POWER TRENCH IGNAL TRENCH
TRENCH SHOWN OUT OF SECTION FOR
CLARITY. PROVIDE PARTITION TO
SEPARATE AC AND DC SIGNALS
SCALE NTS
\ FILE: -
SPACE RESERVED -
FOR OWNER FURNISHED
RTU. APPROXIMATELY
36 Hx24 Wxll D.
(CONTRACTOR TO INSTALL)
REUSE EXISTING YAGI
ANTENNA. PROVIDE NEW
MAST. MATCH EXISTING
HEIGHT (APPROX. 25 FEET
ABOVE GRADE).-AWUST
FOR BEST SIGNAL.
2"x2"x24" LONG ANGLE
FOR SUPPORTING LADDER
WELD TO MAST.
3" HEAVY WALL
GALVANIZED STEEL
PIPE FOR ANTENNA MAST,
ONE CONTINUOUS LENGTH.
PROVIDE OPENING FOR
ANTENNA CABLE.
2" PCS CONDUIT
PROVIDE WATER TIGHT CORROSION
RESISTANT QUICK DISCONNECT AND
PLUG. PUNCH NEW HOLES IN PANEL
AS REQUIRED. WIRE NEW
RECEPTACLE TO EXISTING
TERMINALS -
NOTCH TRENCH COVER ON NON
HINGED SIDE FOR CABLE ENTRY.
LEVEL AK RUBBERIZE EDGES AND PACK WITH
TRANSMITTER �. NON -SETTING DUCT SEAL TO
CABLE `4 , MINIMIZE ODORS.
NEW CONDUIT
TO VALVE VAULT
L: '4G
L. � r
PANEL ELEV/DETAI
Af3: S-3ss-7 / y