Loading...
HomeMy WebLinkAboutWWP2703557.15N a) 7 6 C ut a F- a 00 0 c) 0 w Q z W LL r7L77ETE7AN7F CABINET f100A 120/240V, 30, 4W, 60HZ, 22KAIC MECHANICAL 3P 6 TM INTERLOCK 3P TM 100A 100A -3 &=F- O METERING f SECTION L MOBILE GENERATOR 1� RECEPTACLE o - (MATCH EXISTING) O U U) U O � D_ Q N N *k 120/240V, 30,4W OPEN DELTA SECONDARY UTILITY TRANSFORMER r7PUMP CONTROL PANEL 77UPANE7 2" PCS CONDUIT- ' 100A 120/240V, 30, 4W, 60HZ, 22KAIC ' 4 #2 AWG (0) & 1#6 (G) _T 17- M 0 th P 0 c� - � RA TEA HMCP HMC TM TM 15A ` 15A 4 4 FVNR FVNR SIZE 1 SIZE 1 PM POWER MONITOR RELAY 73VO(C 30 242403 W m Q U W W CY H U Q U- D z Q PMP-01 240VAC FLA=15.2 LIFT STATION PUMP 1 W m Q U U) W H U Q U- z z Q 0 Z o O U � U) U o � N PMP-02 240VAC FLA=15.2 LIFT STATION PUMP 2 1 P 1 P 2oA 20A O WP CONVENIENCE RECEPTACLE � � � � � � 0 1220 0V o � 1 z 3 O06 LLI (7 m d Q Q o U U) 4t ct N W F_ U Q W D < 0.5 1 120V/ FLA=f FLOOD HEATED VALVE V LIGHT ENCLOSURE SUMP P ( „ � LIFT STATION ONE -LINE DIAGRAM SCALE: NTS FILE: 1 ' r RUG9 RTU r KEY NOTES: 1 CONTRACTOR TO INSTALL OWNER PROVIDED RTU PANEL. 2 TERMINATE INSTRUMENTATION AND CONTROL SIGNALS AT 1/0 LOCATIONS AS DIRECTED BY OWNER. OMETER PEDESTAL MUST MEET EUSERC SPECIFICATIONS. REFER TO PSE ELECTRIC SERVICE HANDBOOK FOR ADDITIONAL REQUIREMENTS. OSHOWN WITH OUTER DOOR REMOVED. PROVIDE LOCKING THREE-POINT LATCH ON OUTER DOOR. LSHH-01 LSH-01 LSL-01 LSLL-01 120/240 VAC DISCONNECT RECEPTACLE MANUFACTURER'S CABLE (TYP.) PUMP 1 PUMP VALVE 0.5 VAULT SUMP PUMP PUMP 1 HIGH TEMP MOIST. PUMP 1 MOISTURE PUMP 2 HIGH TEMP MOIST. PUMP 2 MOISTURE PUMP RTU PANEL CONTROL POWER PANEL NEMA 3R ENCLOSURE LEVEL (FLOAT) PUMP 1 PAINTED DARK GREEN MILBANK SWITCH (TYP.) _ LSLL-01 CP3B MODIFIED PER PSE RUN PUMP REQUIREMENTS OR EQUAL. COMMAND RUN COMMAND �, ISOLATED UTILITY #14 XHHW-2 r PULL SECTION AND METER SOCKET 3 (TYP.) > METERING SECTION WITH BYPASS ZSO-04 PUMP 1 y m O BLOCK PER UTILITY RUNNING PUMP 1 H y REQUIREMENTS. WET WELL INTRUSION SWITCH TO ONTR L RUNNING Z ' RTU O PANEL PANEL 240V CBs ZSO-01 PUMP 2 Y Z PUMP 1 CHECK VALVE RUN PUMP 2 m � GENERATOR RECEPTACLE LIMIT SWITCH COMMAND COMMAND Z x (MATCH r EXISTING) ZSO-02 PUMP 2 PUMP �/ s 3 PUMP 2 CHECK VALVE RUNNING PUMP 2 RTU RTU PANEL _ _...._�.. RUNNING POWER/METERWG CABINET SCALE: NTS FILE: RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS THIS DRAWING WAS PREPARED ONLY FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED 910% HEREON AND lS NOT TO BE USED ELSEWHERE 4:000* �0M Date 288/20 I2 By .SCHEMATIC 1 (RTU PANEL SCALE: NTS FILE: PUMP 1 HIGH TEMP PUMP 1 MOISTURE PUMP 2 HIGH TEMP PUMP 2 MOISTURE SM3557 15 SCHEMATIC 2 SCALE: NTS FILE: PUMP 1 HIGH TEMP PUMP 1 MOISTURE PUMP 2 HIGH TEMP PUMP 2 MOISTURE PUMP CONTROL PANEL