Loading...
HomeMy WebLinkAboutWWP2703557.2m a co U .co m 0 c al Iri U- w x N a) 7 .c w 0 Q 0 N O N N N w Q z W J_ H GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE STARTING WORK AND SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES. 2. UNLESS DETAILED, SPECIFIED, OR OTHERWISE INDICATED ON THE DRAWINGS, CONSTRUCTION SHALL BE AS INDICATED IN THE APPLICABLE TYPICAL DETAILS AND GENERAL NOTES. TYPICAL DETAILS SHALL APPLY EVEN THOUGH NOT REFERENCED AT SPECIFIC LOCATIONS ON DRAWINGS. 3. WHERE NO CONSTRUCTION DETAILS ARE SHOWN OR NOTED FOR ANY PART OF WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. ABBREVIATIONS AB ANCHOR BOLT ABC AGGREGATE BASE COURSE AC ASPHALTIC CONCRETE AFF ABOVE FINISHED FLOOR AHR ANCHOR ALM ALARM AL ALUMINUM APPROX APPROXIMATE ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS AUTO AUTOMATIC AVG AVERAGE @ AT BCV BALL CHECK VALVE BSP BLACK STEEL PIPE BV BALL VALVE C CIVIL, CONDUIT CA CONCRETE ANCHOR CB CATCH BASIN CHNL CHANNEL CJ CONSTRUCTION JOINT CL OR CENTERLINE CLP CONTROL PANEL CMP CORRUGATED METAL PIPE CND CONDUIT CO CLEANOUT COMP COMPACTED CONC CONCRETE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUE (D) (OUS) OR CONTROL CP CONTROL POINT CPLG COUPLING CTR CENTER D DRAIN, DEPTH DEG DEGREE DET DETAIL DIA OR DIAMETER DIM DIMENSION DIP DUCTILE IRON PIPE DMJT DISMANTLING JOINT DWG DRAWING E EAST, ELECTRICAL EA EACH EL OR ELEV ELEVATION ELL ELBOW ELEC ELECTRIC (AL) EMBED EMBEDMENT ENGR ENGINEER EOP EDGE OF PAVEMENT EQL EQUAL EQPT EQUIPMENT EXIST EXISTING FLG FLANGE FM FORCE MAIN FRP FIBERGLASS REINFORCED PLASTIC FT FOOT, FEET GP GRINDER PUMP ID INSIDE DIAMETER OR INSIDE DIMENSION IE, I.E. INVERT ELEVATION INVT INVERT L LENGTH LF LINEAR FEET M MECHANICAL MAX MAXIMUM MDD MAXIMUM DRY DENSITY MECH MECHANICAL MFRS MANUFACTURER'S MH MANHOLE, SANITARY MIN MINIMUM MISC MISCELLANEOUS N NORTH NE NORTH EAST NO NUMBER NOM NOMINAL NTS NOT TO SCALE NW NORTHWEST OD OUTSIDE DIAMETER PD PUMPED DRAINAGE PL PROPERTY LINE R OR RAD RADIUS RDCR REDUCER REC RECORD REF REFERENCE REINF REINFORCE (D) (ING) (MENT) READ REQUIRED RFCA RESTRAINED FLANGED COUPLING ADAPTER S SEWAGE OR SOUTH SCH SCHEDULE SCV SWING CHECK VALVE SD STORM DRAIN SE SOUTHEAST SIM SIMILAR SP SUMP PUMP SPEC SPECIFICATION SS SANITARY SEWER, GRAVITY SSFM SANITARY SEWER FORCE MAIN SSMH SANITARY SEWER MANHOLE SST, SSTL STAINLESS STEEL STA STATION STD STANDARD STL STEEL SW SOUTHWEST S/W SIDEWALK TEL TELEPHONE TDH TOTAL DYNAMIC HEAD TOC TOP OF CONCRETE TYP TYPICAL V OR VLV VALVE VERT VERTICAL VOL VOLUME W WEST, WIDTH, WATER WM WATER METER W/ WITH W/0 WITHOUT 2W NON -POTABLE WATER PMP PUMP RECORD DRAWING PNPANEL PS L POUND PER SQUARE INCH THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED PV PLUG VALVE IN PART ON INFORMATION PROVIDED BY OTHERS PVC POLYVINYL CHLORIDE PVMT PAVEMENT THIS DRAWING WAS PREPARED ONLY FOR THE PROJECTAND SITE SPECIFICALLY IDENTIFIED COA% 110% HEREON AND IS NOT TO BE USED ELSEWHERE Date 288 ho 12 By /e)� SURVEY LEGEND (EXISTING LINE WORK) WATER VALVE HYDRANT FIRE DEPT. CONNECTION WATER METER POST INDICATOR VALVE MANHOLES (SS/SD) CB POWER/UTILITY POLE GUY ANCHOR JUNCTION BOX POWER TRANSFORMER POWER/TELEPHONE VAULT POWER METER TELEPHONE/TV RISER GAS VALVE GAS METER STREET LIGHT SPOT ELEVATION SIGN MAILBOX ROCKERY CONIFEROUS TREE DECIDUOUS TREE COTTONWOOD IRRIGATION CONTROL VALVE BUILDING MATERIALS MONUMENT NOT TIED THIS SURVEY FOUND CASED MONUMENT SET PK NAIL/ALUMINUM WASHER STAMPED "PACE CONTROL" SET 5/8" IRON REBAR W/ YELLOW PLASTIC CAP STAMPED L.S. #33130 UNLESS OTHERWISE STATED. CENTER LINES PROPERTY LINES RIGHT-OF-WAY LINES EASEMENT LINES LOT LINES DITCH LINE WATER LINE SANITARY SEWER LINE SANITARY SEWER FORCE MAIN STORM DRAIN LINE GAS LINE UNDERGROUND POWER LINES UNDERGROUND TELEPHONE LINES UNDERGROUND CABLE TV LINES OVERHEAD UTILITY LINES CHAIN LINK FENCE WIRE FENCE WOOD FENCE VIEW IN SECTION MATERIAL EXISTING REMOVE NEW CLASS "A" "B" AND "D" CONCRETE CLASS "C" CONCRETE STEEL CAST IRON OR FIBERGLASS ALUMINUM SOIL VIEW IN PLAN (NEW SHOWN - EXISTING SCREENED) GRATING SPAN SLURRY SEAL PAVEMENT MECHANICAL LINE WORK NEW OR EXISTING STRUCTURES NEW OR EXISTING STRUCTURES HIDDEN NEW PIPING (TRIPLE LINES) NEW PIPING HIDDEN (TRIPLE LINES) NEW PIPING (SINGLE LINE) NEW PIPING HIDDEN (SINGLE LINE) EXISTING PIPING (TRIPLE LINES) EXISTING PIPING HIDDEN (TRIPLE LINES) EXISTING PIPING (SINGLE LINE) EXISTING PIPING HIDDEN (SINGLE LINE) NEW EQUIPMENT OR PIPING CENTERLINE EXISTING- EQUIPMENT OR PIPING CENTERLINE NEW EQUIPMENT NEW EQUIPMENT HIDDEN EXISTING EQUIPMENT NEW FITTING EXISTING TO BE REMOVED NEW PIPING CALL -OUT EXISTING PIPING CALL -OUT MECHANICAL SYMBOLS SWING CHECK VALVE PLUG VALVE BALL VALVE FLANGED JOINT WELDED JOINT PUSH -ON JOINT SCREWED JOINT FLANGED COUPLING ADAPTER DISMANTLING JOINT RESTRAINED FLANGED COUPLING ADAPTER DRAWING CROSS REFERENCE A T TITI I — DETAIL OR SECTION IDENTIFICATION DETAIL OR SECTION TAKEN ON THE SAME SHEET DETAIL OR SECTION IS TAKEN ON THE DRAWING INDICATED TYPICAL DETAIL REFERENCE BUBBLE TYPICAL DETAIL NUMBER IDENTIFICATION DETAIL OR SECTION IDENTIFICATION —DETAIL OR SECTION REFERENCE BUBBLE DETAIL OR SECTION IS TO BE FOUND ON THE SAME SHEET DETAIL OR SECTION IS TO BE FOUND ON THE DRAWING INDICATED TYPICAL DETAIL IS TO BE FOUND ON THE TYPICAL DETAIL DRAWINGS AT CROSS REFERENCE DESIGN CRITERIA HYDRAULIC REQUIREMENTS PUMP TYPE NUMBER OF PUMPS RATED CAPACITY, EACH PUMP MOTOR HORSEPOWER, EACH PUMP FORCE MAIN SUBMERSIBLE, CHOPPER 2 (1-DUTY, 1-STANDBY) 125 GPM @ 24 FT TDH 5.0 4 INCH, DI s 355702