Loading...
HomeMy WebLinkAboutWWP2703557.9I U) w ril N D CT ui 0 E Lo Lo N CD N N N WET WELL P662 3'-0" TYP N�RTN GRADE EL 27.20 2'-6" TOP SLAB E 8'-0" INSIDE DIA PRECAST CONCRETE —71 MANHOLE W/ 10'-6" DIA EXTENDED BASE o a M-03 PER SUB -SECTION 10.02084 Q WET WELL 1 4 1 6" PVC VENT ❑ P662 (TYP) M-03 I TYP ll 17 a G a 4 5 9 0 II WELL BOTTOM I I M-03 1 a Q / 13 lil EL CCESS HATCH A257 I I PENING 4'-0" x 5'-6"" TYP TYP a ( ) � FRP LEAR OPENING) HANDRAIL FFSET 3" FROM Z-\. 6 / P656 (TYP) ENTER �� _ _ _ _ a I I TYP FRP GRATING AND 3 I I - -i - - - - - - - M-03 � PUMP NO. 2 HANDRAIL � � 13 � G I PMP-02 I I 1 I FRP HANDRAIL 18 I I II rB x1l 1 11 (TYP) 4" SSFM (TYP) o I ! Q 7 (TYP) WET WELL I I < a PUMP NO: 1 _ a EL 18.24_ EL 18.0 I o I PMP-01 I I 1 o I I r I OPEN I I a EL 17.03 I I a a . P668 (TYP) FRPIBEAM TYP I I I I I I I -- -- --� a TEE I I I EL 15.58 a ILA C P302 (TYP) IE 15.91 4 TYP 16 I I Q -L a 8 SS \\\ HIGH LEVEL ALARM EL 13.3 I I \ I I PUMP 2 ON EL 13.0 PUMP 1 ON EL 12.5 BEVEL CUT ! I EL 12.0 � AT 45° ANGLE I I 2 1 3 (TYP) a PUMP(S) OFF EL10.8 12 �1 FRP GRATING (TYP) -{ 8� LEVEL TRANSMITTER #4 EPDXY GROUTED DOWEL W/ STD 180 4"x3" RED HOOK. MIN 6" EMBEDMENT IN WET WELL a WALL. MIN 12" EMBEDMENT IN CONC FILL. - III I 8 FLOAT SWITCHES (TYP 4) SPACE DOWELS @ 2'-0" EACH WAY a I I CLASS C CONCRETE PER a F SUB -SECTION 10.03300 Z M-03 a #4 EPDXY GRO EXTENDED BASE - 60° 15 HOOK. MIN 6" E 4TYP) a C WALL. MIN 6" E a @ PUMP DISCH a G LADDER = MIN EL 8.12 WET WELL PLANG a A 14 a C-04 j SCALE: 1" = 1'-0" FILE:8235B10-M-102 a RECORD DRAWING THESE RECORD DRAWINGS HAVE BEEN PREPARED BASED IN PART ON INFORMATION PROVIDED BY OTHERS THIS DRAWING WAS PREPARED ONLY FOR THE PROJECT AND SITE SPECIFICALLY IDENTIFIED 9140% HEREON AND IS NOT TO BE USED ELSEWHERE 1: � Date 288 /20 2 By 3 WET WELL - SCALE: 3/4" = 1'-0" FILE: 82351310-M-302 SECTION 22.91 GENERAL NOTES: A. ALL SUPPORTS AND FASTENERS SHALL BE CONSTRUCTED OF STAINLESS STEEL. B. NOT ALL OF THE REQUIRED PIPE SUPPORTS ARE SHOWN ON THE DRAWINGS. CONTRACTOR SHALL PROVIDE ALL OF THE PIPE SUPPORTS SHOWN ON THE DRAWINGS AND ADDITIONAL PIPE SUPPORTS AS REQUIRED PER SPECIFICATIONS. SUPPORT SPACING SHALL BE AS SPECIFIED UNLESS SPECIFICALLY INDICATED OTHERWISE. C. NOT ALL OF THE REQUIRED FITTINGS ARE SHOWN ON THE DRAWINGS. CONTRACTOR SHALL PROVIDE ALL OF THE FITTINGS AS REQUIRED FOR PIPING ARRANGEMENTS SHOWN ON THE DRAWINGS AND PER EQUIPMENT FURNISHED_ KEY NOTES: 1 SEE CIVIL DWGS FOR CONTINUATION. 2 PUMP MFR TO PROVIDE SST INTERMEDIATE GUIDE BRACKETS. 3 FITTINGS, PIPING, AND APPURTENANCES SHOWN SHALL BE THE SAME FOR BOTH PUMPS. OFABRICATED SST ANGLE, 3x3x1/4" THICK, LENGTH AS REQD. SUPPORT TO WALL USING TWO 1/2" CONCRETE ANCHORS. FABRICATE ANGLE WITH SLOTTED HOLES FOR ANCHORAGE. STRAP PIPE TO ANGLE USING SST U-BOLT AND NUTS. OSST CHAIN AS SPECIFIED IN SUB -SECTION 10.11311 OFRP LADDER PER TYPICAL DETAIL A257/TYP. EXTEND 3'-6" ABOVE FRP GRATING. OBLOCK OUT FOR BASE SUPPORT. COORDINATE DIMENSIONS W/ PUMP MFR OSEE ELECTRICAL DWGS FOR DETAILS. 9 ROUTE DOWN WALL. TERMINATE AT EL 14.0. 10 SEE DWG C-04, ENLARGED SITE PLAN FOR DOOR SWING DETAILS. 11 MAX DISTANCE FROM INSIDE EDGE OF HATCH OPENING TO FURTHEST POINT ON PUMP = 2'-0". 12 MINIMUM PUMP OPERATING LEVEL = EL 10.6. 13 FASTEN 1" THICK X 5" WIDE FRP STEP TO LADDER WITH SST CONNECTIONS. LENGTH AS REQUIRED TO SPAN WIDTH OF LADDER. MODIFY LADDER CONNECTION TO WET WELL AS REQUIRED TO ACCOMODATE FRP STEP. 14 ANCHORAGE AS RECOMMENDED BY MFR. 15 4 7/8" PER SPECIFIED PUMP MFR. ADJUST PER PUMP MFR RECOMMENDATIONS FOR OTHER MFR. 16 INFLUENT 8" SS SHOWN ROTATED OUT OF SECTION. 17 PER TYP DET A251, SIM, NO GUARDRAIL, GATE, AND FLOOR ANCHORAGE. SUPPORT TO ACCESS HATCH OPENING PER MFRS RECOMMENDATIONS. 18 PROVIDE SST CHAIN AND HOOK AT TOP OF HAND RAIL FROM HAND RAIL TO WET WELL WALL. ANCHOR INTO WET WELL WITH 3/8" SST EYE BOLT, EMBED MIN 4" WITH EPDXY. UTED DOWEL W/ STD 180° MBEDMENT IN WET WELL MBEDMENT IN CONC FILL (TYP ARGE ELBOW AND LADDER, 3" EMBEDMENT IN CONC FILL) 12" CSBC COMPACTED TO 95% MDD PER ASTM D1577. 5-355109