HomeMy WebLinkAboutWWP2703621.2w
Q
z
U
w
0
z
LEGEND
ROADWAY
ROADWAY CENTERLINE
PROPERTY / LOT LINE
RIGHT-OF-WAY
BOUNDARY LINE
EASEMENT LINE
BUILDING SETBACK LINE
ROLLED CURB AND GUTTER
VERTICAL CURB AND GUTTER
EXISTING PROPOSED
- - _ _
- -
_ _ _ _
- -
EXISTING
WETLAND FLAG
BIKE RACK
DEBRIS PILE
FIRE PIT
BOLLARD
HORSE SHOE PIT
MAILBOX
FEATURES
POWER POLE W/DROP LINE & LIGHT
POWER POLE W/DROP LINE, LIGHT & TRANSFORMER
POWER POLE W/DROP LINE & TRANSFORMER
POWER POLE W/LIGHT
POWER POLE W/LIGHT & TRANSFORMER
POWER POLE
POWER POLE W/TRANSFORMER
CONTOUR (MINOR)
--
MILE POST MARKER
PAD MOUNTED TRANSFORMER
CONTOUR (MAJOR)
- - 820- - - -- s2o --
FOOTING DRAIN FLOWPATH
�_ _ �_
-;
SOIL LOG
POWER VAULT/MANHOLE
SPOT ELEVATION
X 2�?
SIGN
SIGNAL CONTROL BOX
O
O
TOP/TOE OF SLOPE
L-------- 1-------1 1
,
SEPTIC DISTRIBUTION BOX
SIGNAL JUNCTION BOX
CONCRETE SIDEWALK
E--=-= ===== -===========-=1
SANITARY SEWER STUB MARKER POST
TRAFFIC PEDESTRIAN POLE
U
U)
CONCRETE BLOCK WALL
IMMMIC3=CX3=CX3=CX3=CX3=r=
SEPTIC VENT
TRAFFIC SIGNAL POLE
ROCKERY
STORM PIPE INLET/OUTLET
TRAFFIC SIGNAL POLE W/LIGHT
V
BARRICADE
_
STORM DRAIN STUB MARKER POST
FIBER OPTIC MANHOLE
BOLLARDS
ROOF DRAIN
FIBER OPTIC STUB MARKER POST
}.
MAILBOX
DOWNSPOUTS
o
O
CATCH BASIN
TELEPHONE GUY ANCHOR
rr
W
STORM DRAINAGE
CABLE TV MARKER POST
TELEPHONE ANCHOR POLE
m
CATCH BASIN TYPE 1 W/GRATE
0
CABLE TV RISER
TELEPHONE JUNCTION BOX (UG)
—1
CATCH BASIN TYPE 1 W/SOLID LID
0
SATELLITE DISH
TELEPHONE MANHOLE
r
CATCH BASIN TYPE 2 W/GRATE
LUMINAIRE W/ARM
TELEPHONE STUB MARKER POST
W
CATCH BASIN TYPE 2 W/SOLID LID
Q
STORM DRAIN MANHOLE
LUMINAIRE
TELEPHONE POLE
BEEHIVE MANHOLE
LANDSCAPE LIGHT
TELEPHONE RISER
a_
YARD DRAIN (ROUND LID)
YARD LIGHT (UNDER 10' TALL)
FIRE DEPT CONNECTION
z
YARD DRAIN
GAS STUB MARKER POST
HOSE BIB
0
STORM DRAIN CLEAN -OUT
GAS VALVE
iR
IRRIGATION CONTROL VALVE
U)
STORM DRAIN PIPE
z
OIL FILLER CAP
'`
WATER MANHOLE
W
ROOF DRAIN
GUY ANCHOR
WATER STUB MARKER POST
F-
SD SERVICE 6" CPEP WITH
X
INVERT 0 END OF PIPE
GUY POLE
Mw�
MONITORING WELL
W
F, ,
SANITARY SEWER
POWER GRATE
POST INDICATOR VALVE
SANITARY SEWER MANHOLE
ELECTRICAL JUNCTION PULL/BOX
SPRINKLER HEAD
'�.
SANITARY SEWER CLEANOUT
O
ELECTRICAL STUB MARKER POST
WATER VAULT
W
U)
SANITARY SEWER GRAVITY
--- -- - _ -
ELECTRICAL METER
WATER WELL
i'
SANITARY SEWER FORCE MAIN
--- FM - -- ____��__�
GAS
D li
GUARD RAIL
Ir
Q
TRAFFIC
OIL
-0
FENCE, BOARD
STRAIGHT/RIGHT TURN ARROW
A
!#
STRAIGHT/RIGHT TURN ARROW
�
"1
POWER (BURIED)
><
FENCE, BARB -WIRE
z
Q
LEFT/RIGHT TURN ARROW
y
M
POWER (AERIAL)
-0
FENCE, CHAIN -LINK
U7
STRAIGHT/LEFT/RIGHT TURN ARROW
+
+
FIBER OPTICS
-
FENCE, ELECTRIC
LEFT TURN ARROW
f1
�1
TELEPHONE (BURIED)
-
FENCE HOG WIRE
QRIGHT
TURN ARROW
TELEPHONE (AERIAL)
FENCE, SPLIT RAIL
a_
STRAIGHT ARROW
♦
♦
—
w
TV CABLE (BURIED)
FENCE, WIRE
HANDICAP PARKING
�`
&
�
BIKE LANE
cabcoo
TV CABLE (AERIAL)
FENCE WROUGHT IRON
Q
TRAFFIC SIGN
.I f
.I..-
CREEK OR STREAM CENTERLINE
RAILROAD TRACKS
Ir
INFORMATION SIGN
T
T
STREET LIGHT
WETLAND WITH BUFFER
�
STREAM WITH BUFFER
=
T.E.S.C.P.
SURVEY
CONSTRUCTION SEQUENCE:
CLEARING LIMITS
PROPOSED MONUMENT IN CASE
1. THE CONTRACTOR SHALL COMPLETE THE INSTALLATION OF THE
FILTER FABRIC FENCE
A A
®
FOUND MONUMENT IN CASE
SANITARY SEWER LINES WITHIN ONLY ONE ROADWAY BLOCK AT
A
�s�.� CUTOFF SWALE
OO oM
PROPOSED MONUMENT (AS DEFINED)
TIME AND SHALL COMPLETE THE TEMPORARY HOT -MIX ASPHALT
RESTORATION OF EACH ROADWAY BLOCK BEFORE BEGINNING
INTERCEPTOR DITCH
@0m
FOUND MONUMENT (AS DEFINED)
WORK IN ANOTHER BLOCK.
- -� - -�- - N.G.P.E. FENCE
2. TEMPORARY RESTORATION OF
TRENCHES FOR OVERNIGHT USE
SHALL BE ACCOMPLISHED BY
USING HOT -MIX ASPHALT (HMA).
® ROCK CHECK DAM
A
DELTA
STEEL PLATES MAY BE USED
OVERNIGHT TO COVER THE LAST
(R)
RADIAL BEARING >
SECTION OF TRENCH. STEEL
PLATES MUST BE PINNED DOWN
SEDIMENT FILTER
<
AND ASPHALT RAMPS/WEDGES
MUST BE PLACED AROUND THE
(NR)
NON —RADIAL BEARING
PLATES. STEEL PLATES SHALL NOT BE USED ON STEEP GRADES
® STRAW BALE
OR WHERE STEEL PLATES PRESENT A ROADWAY HAZARD.
L
ARC LENGTH
GRAVEL CONE
® RIP RAP PAD
CONSTRUCTION ENTRANCE
WARNING:
THE UTILITY LOCATIONS SHOWN
ARE APPROXIMATE ONLY. DEPTH
UNKNOWN. CALL 1 —800-424-5555.
®CONSULTING ENGINEERS LLC � .`P CJ. O FlRST SUBMfTTAL
181 S 333rd Street I® I I I 1 SECOND SUBMI'TTAL
Bldg C, Suite 210
Federal Way, WA 98003
FEDERAL WAY (253) 838-6113
www.esmcivil.com EYERFT (425) 297-9900
ELLENSBURG (509) 962-2W8 43175
Civil Engineering Land Surveying Land Planning d�Q Q
Public Works I Project Management I Landscape Architecture
ESM JOB # 1352-020-01 1 V �ONAL�'I'�, _
REVISION
ABBREVIATIONS
AVE
AVENUE
ID
INSIDE DIAMETER
AC
ASBESTOS CEMENT PIPE
IE
INVERT ELEVATION
ADJ
ADJACENT
IN
INCHES
ALUM
ALUMINUM
L
LENGTH
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
LB
POUNDS
AP
ANGLE POINT
LF
LINEAL FEET
ASPH
ASPHALT
MAX
MAXIMUM
ASTM
AMERICAN SOCIETY OF TESTING AND MATERIALS
MFR
MANUFACTURER
ASSY
ASSEMBLY
MH
MANHOLE
BF
BLIND FLANGE
MIN
MINIMUM
BLDG
BUILDING
MJ
MECHANICAL JOINT
BLK
BLOCK
MISC
MISCELLANEOUS
BO
BLOW OFF
N
NORTH
BOW/BW
BOTTOM OF WALL
NO
NUMBER
BVC
BEGIN VERTICAL CURVE
NITS
NOT TO SCALE
BW
BACK OF WALK
OC
ON CENTER
CTR
CENTER
OD
OUTSIDE DIAMETER
CB
CATCH BASIN
OHW
ORDINARY HIGH WATER
Cl
CAST IRON
PI
POINT OF INTERSECTION
CL/�
CENTERLINE
PP
POWER POLE
CLR
CLEAR
PVI
POINT OF VERTICAL INTERSECTION
CMP
CORRUGATED METAL PIPE
PE
POLYETHYLENE
CO
CLEANOUT
PERF
PERFORATED
CONIC
CONCRETE
PVC
POLYVINYL CHLORIDE
C
CONDUIT
PVMT
PAVEMENT
CONN
CONNECTION
PVT
POINT OF VERTICAL TANGENCY
CONTR
CONTRACTOR
PC
POINT OF CURVATURE
CONT
CONTINUED
PT
POINT OF TANGENCY
CY
CUBIC YARDS
QTY
QUANTITY
CL
CLASS
RET
RETAINING
CIF
CUBIC FEET
RR
RAILROAD
CFS
CUBIC FEET PER SECOND
R
RADIUS
DC
DEGREE OF CURVATURE
RED
REDUCER
DI
DUCTILE IRON
REINF
REINFORCED
DIA/0
DIAMETER
REQ
REQUIRED
DOT
DEPARTMENT OF TRANSPORTATION
R/W
RIGHT OF WAY
DIM
DIMENSION
S
SOUTH
DWGS
DRAWINGS
SCH
SCHEDULE
D
DRAIN
SD
STORM DRAIN
EOP
EDGE OF PAVEMENT
SF
SQUARE FEET
E
EAST
SHT
SHEET
ELEV
ELEVATION
SPECS
SPECIFICATIONS
EL
ELEVATION
SQ
SQUARE
ELEC
ELECTRICAL
SS
SANITARY SEWER
EVC
END VERTICAL CURVE
STA
STATION
EXIST
EXISTING
STD
STANDARD
FDC
FIRE DEPARTMENT CONNECTION
TC
TOP OF CURB
FG
FINISH GRADE
TEL
TELEPHONE
FIG
FIGURE
THRD
THREADED
FIN
FINISHED
THRU
THROUGH
FL/FL
FLOWLINE
TOW/TW
TOP OF WALL
FL
FLANGE
TYP
TYPICAL
FT
FEET
VERT
VERTICAL
FM
FORCE MAIN
W
WEST
GA
GAUGE
W/
WITH
GALV
GALVANIZED
W/0
WITHOUT
GI
GALVANIZED IRON
WSS
WATER SAMPLING STATION
GV
GATE VALVE
1 SURVEYED-
2 DESIGNED:
DRAWN:
CHECKED:
A P P R I APPROVED
SCA_E
NM
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
GENERAL NOTES:
1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE
LATEST STANDARDS AND SPECIFICATIONS OF THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT AND THE 2008 EDITION OF
THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS
APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
RENTON STANDARD PLANS & SPECIFICATIONS. SOME STANDARD
DETAIL DRAWINGS MAY HAVE BEEN MODIFIED FOR THE CONTRACT.
THE CONTRACTOR SHALL REFER TO DETAIL DRAWINGS INCLUDED
IN THE CONTRACT DOCUMENTS. A SET OF APPROVED PLANS
SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
DISTURBANCE. FOR UTILITY LOCATES CALL 800-424-5555 (OR
81 1) A MINIMUM OF 72 HOURS PRIOR TO EXCAVATION.
3. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE
SUBMITTED AT THE PRE -CONSTRUCTION MEETING. ANY
MODIFICATIONS TO THE APPROVED TRAFFIC CONTROL PLAN SHALL
BE RESUBMITTED AND APPROVED PRIOR TO IMPLEMENTATION.
4. ALL FITTINGS SHALL BE BLOCKED PER CITY OF RENTON
STANDARD DETAILS UNLESS OTHERWISE NOTED.
5. THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO
REMOVE DUST AND DEBRIS FROM PAVEMENT AREA AS DIRECTED
BY THE ENGINEER. FLUSHING OF STREETS SHALL NOT BE
PERMITTED.
6. BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR
SHALL PROVIDE A CATCH BASIN FILTER FOR ALL DOWNHILL
STORM DRAIN INLETS AND CATCH BASINS. THE CONTRACTOR
SHALL PERIODICALLY INSPECT THE CONDITION OF ALL FILTERS
AND REPLACE AS NECESSARY.
7. PAVEMENT MARKINGS (E.G. LANE LINE BUTTONS OR PAINT, STOP
BARS, CROSSWALKS, ETC.) DAMAGED OR REMOVED DURING
CONSTRUCTION SHALL BE REPLACED IN KIND.
AIr1TC .
1. LOT LINES ARE BASED ON CIS INFORMATION AND ARE FOR
GENERAL INFORMATION ONLY.
2. GRAVITY SANITARY SEWER PIPE MATERIAL:
• PVC SDR35 - 4' TO 15' OF COVER
• PVC C900 - LESS THAN 4' OF COVER
• PVC C900 - OVER 15' OF COVER
• PVC C905 - PIPE DIA. GREATER THAN 18" WITH LESS THAN
4' OF COVER OR GREATER THAN 15' OF COVER
SURVEY DATUM:
HORIZONTAL DATUM:
NAD83(91) WASHINGTON STAE PLANE COORDINATE SYSTEM NORTH
ZONE
VERTICAL DATUM:
NAVD 1988 CITY OF RENTON PUBLISHED BENCH MARKS
#1909 CASED MONUMENT WITH LEAD AND TACK AT THE INTERSECTION
OF SE 139th PLACE AND 156TH AVENUE SE.
ELEVATION = 408.64
#2088 CASE MONUMENT WITH M- BRASS DISC AT THE INTERSECTION
SE 142ND PLACE AND 156TH AVENUE SE.
ELEVATION = 372.34
CITY OF RENTON PUBLISHED BENCH DESCRIPTIONS ARE REVERSED
FOR
BENCHMARKS #2088 AND #1909
SITE CONTROL:
ESM CONTROL POINT LOCATED 27' NW OF THE INTERSECTION OF SE
136TH ST AND 168TH AVENUE SE.
N 178033.9669, E 1323118.6406, ELEVATION = 466.25
ESM CONTROL POINT LOCATED 511' WEST OF THE INTERSECTION OF
SE 136TH ST AND 168TH AVENUE SE ON THE SOUTHERLY EDGE OF
ASPHALT.
N 178031.6592, E 1322625.8698, ELEVATION = 454.97
-362102
CHECKED FOR COMPLIANCE TO CITY STANDARDS
VERTICAL NAVD 1986 HERITAGE PLAT SANITARY SEWER EXTENSION DATE:02/0/�6/20
HORIZONTAL: NAD 1983/199'. }� CITY
T � O � 02 W Ly1
PHASE 1 (LIBERTY HIGH SCHOOL) FIELDBOOK
RENTON PAGE.
DRAWING NO
DATUM Planning/Building/Public Works Dept. LEGEND AND GENERAL NOTES LG-01
IHFF' 2 OF:' 6
7�
Y