Loading...
HomeMy WebLinkAboutWWP2703621.28W Q z U LLI U ff N W Q Q_ z 0 U) z w F_ X W w w Q z Q F-- Q J W aC W A PORTION OF THE NW 1 /4 OF THE SE 1 /4 OF SEC 13, TWP 23 N, RGE 5 E, WM, KING CO, WA 1ARTH AVE SE 169TH AVE SE PID # 7229800055 PID # 7229800060 1 PID # 7229800310 i PID # 7229800315 PID # 7229800320 PID # 7229800325 PID # 7229800330 HOUSE #16804 VACANT LOT VACANT LOT i HOUSE #16916 HOUSE #16936 HOUSE #16940 HOUSE #13851 S.S. 1 FINISHED FLOOR ELEV.=472t I ( FINISHED FLOOR ELEV.=472f FINISHED FLOOR ELEV.=474f FINISHED FLOOR ELEV.=480t FINISHED FLOOR ELEV.=487t I I I 1 f I 1 � EXi,3 i iNG JJ r-> �� I-� r� f I I /� EXISTING POWER EXISTING 12" _;,.:_ _ TELEPHONE rI 1 1 CONC. CULVERT FIBER -TIC ( /// EXISTING EXISTING 12" tp L_ _-- _-- I l ql e if WATER CMP CULVEO RT�� O ? EXISTING 12" 1 9 ` V +0o Q� 2+00 ' — L—1 �� -- ` CONC. CULVERT 6 V) EXISTING l,r LHiN -- I 4+-0-u' \ _ — _ + LINK FENCE T— 5+00 - _ LJ EX. S.S.M.H. #H1 -10, TYPE 1 -48"0 °I— --- _ + 8�0 -.�. - - — — -- ____1 J- _ Q H STA, 1 +44.63, 4.78 RT. r"' _ _ - - — _ _ �7_ _ _ �,--____ ---- _ --�- �00— � o V) EXISTING- EXISTING 12" 290 L.F., --- — GATE CONC. CULVERT 8"0 S.S GAS 1 1 1 „ _% 241 L.F., - --- H I 1 I XISTING 12 , -- __ _ W I MP CULVERT 8 S.S EDGE OF - tx1S i Iltiv `�"' `— Z OO 1 PAVEMENT GAS 400 L.F., J I 1 I I 1 8"0 S.S = I I INT'X STA. 4+39,57, SE 140TH ST W - 169TH ST SE I CLLLJ PID # 7229800066 PID # 7229800065 I PID # 7229800210 PID # 7229800205 PID # 7229800200 LIJ HOUSE #16805 HOUSE #14005 VACANT LOT VACANT LOT VACANT LOT VI FINISHED FLOOR ELEV.=472t FINISHED FLOOR ELEV.=472t 500 490 :0 470 460 450 WARNING: THE UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY. DEPTH UNKNOWN. CALL 1-800-424-5555. 1 +00 PID # 7229800195 HOUSE #14011 S.S.M.H. #H2-01, TYPE 1-48" 0 S.S.M.H. #H2-02, TYPE 1-48" 0 FINISHED FLOOR ELEV.=484t STA. 5+23.51 , 5.00 RT. STA. 9+23.51 , 5.00 RT. SE 140TH ST INT'X STA. 4+39.57, SE 140TH ST 169TH AVE SE U_ ~ W � n CIOcO 0)0r-0 Z a-�t Of d7 Q� c0 r1j L(� cD CO + W CO Q + W (',I Q + W + Cn + m+ W J N� to 4< Q 4< �LLLItH _� aX ~X aX F�-X �X F__X +XW (nW (nW U)W LnW 0W0W LnW— 290 L.F., 8"0 PVC SDR-35 S.S. @ S=0.40% I I X. S.S.M.H. H1-10 TYPF 1-60"o I E I.E. IN = 462.01, 8"0 2+00 ®CONSULTING 34400 8th Avenue South ENGINEERS L L C Suite 205 Federal Way, WA 98003 FEDERAL WAY (253) 838-6113 www.esmcivil.com EVERE,r (425) 29 —8400 MENSOURG (509) 962-2608 Civil Engineering Land Surveying Land Planning Public Works I Project Management I Landscape Architecture ESM JOB # 1352-006-007 �t3t•I•l 4+00 ORIGINAL GROUND ® CL 241 L.F., 8" 0 PVC SDR-35 S.S. @ S=0.40% �.z-.nn.n. gnz--u I , I I rr- RIM = 470.56 I.E. IN = 463.27, 8" 0 I.E. OUT = 463,17, 8" 0 5+00 N 00 + Q 0 Q X-- tJ) W i 400 L.F., 8" 0 PVC SDR-35 S.S. @ S=0.56% 48" I S.S.M.H. #H2-02, TYPE 1 -48" RIM = 471.85 I.E. IN = 464.33, 8" 0 I.E. OUT = 464.23, 8"0 6+00 7+00 0 FIRST SUBMITTAL ESM 09/18/12 SURVEYED: SCALE: VERTICAL: NAVD 7988 1 SECOND SUBMITTAL ESM 01%25/13 DESIGNED: 1 0 '50 • HORIZONTAL: NAD 1983/1991 2 MYLAR SUBMITTAL ESM 01/28/13 on 3 1 ST REVISION ESM 09/10/13 DRAWN: �L 4 REVISED MYLAR SUBMITTAL ESM 09/19/13 CHECKED:♦ ONE INCH DATUM AT FULL SCALE IF NOT ONE INCH DR APPROVED: SCALE ACCORDINGLY N0. REVISION BY DATE APB 500 490 O O O1 O(n 0V) 480 O w 470 V) 2 W 0 z st J = W 460 V) �w 450 10+00 &R CI Y O E RENTON Planning/Building/Public Works Dept. SCALE: 1"=50' HORIZ. 1"=10' VERT. 50 25 0 50 100 S.E. 133RD STREET a BRtARW00D co LEMENTA F- S.E. 134TH STREET S.E. 1 6TH STREET ��-�-_-- -`O-I LIBERTY H.S. '1 N D v D S.E. 140TH STREET N I S.E. 144TH1 (STREET MAYW00D M.S. KEY MAP NOT TO SCALE NOTES: 1. EXISTING UTILITIES ARE SURFACE LOCATED ONLY. CONTRACTOR TO VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION. 2. FOR TRENCH SECTION SHEET DT-01. 3. FOR SIDE SEWER CONNECTIONS SEE SIDE SEWER CONNECTION DETAIL SHEET SS-09. SEWER STUBS TO THE PROPERTY LINE SHALL BE 6-INCH @ 2% SLOPE FROM MAIN TO RIGHT-OF-WAY THEN UP TO SEWER STUB ELEVATION UNLESS OTHERWISE NOTED. 4. MANHOLES LOCATED IN DRIVEWAY APPROACHES SHALL BE SET TO FINISH GRADE. MANHOLES LOCATED IN UNIMPROVED AREAS ARE TO BE SET A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISH GRADE, OR MUST HAVE 2'DIA. CONCRETE RING POURED AT GRADE. WHERE MANHOLES LOCATED IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. S=362 128 CHECKED FOR COMPLIANCE TO CITY STANDARDS HERITAGE PLAT SANITARY SEWER EXTENSION PHASE 2 SE 140TH ST PLAN AND PROFILE: STA. 1 +00.00 TO STA 10+00.00 09/19/201 PAGE DRAWING NO: SS-08 SHEET: OF: 12 15