HomeMy WebLinkAboutWWP2703621.34LEGEND
PROPOSED
EXISTING FEATURES
z
_O
U)
z
W
X
W
W
w
0
{)
ROADWAY
ROADWAY CENTERLINE
PROPERTY / LOT LINE
RIGHT—OF—WAY
BOUNDARY LINE
EASEMENT LINE
BUILDING SETBACK LINE
ROLLED CURB AND GUTTER
VERTICAL CURB AND GUTTER
CONTOUR (MINOR)
CONTOUR (MAJOR)
FOOTING DRAIN FLOWPATH
SPOT ELEVATION
TOP/TOE OF SLOPE
CONCRETE SIDEWALK
CONCRETE BLOCK WALL
ROCKERY
BARRICADE
BOLLARDS
MAILBOX
DOWNSPOUTS
STORM DRAINAGE
CATCH BASIN TYPE 1 W/GRATE
CATCH BASIN TYPE 1 W/SOLID LID
CATCH BASIN TYPE 2 W/GRATE
CATCH BASIN TYPE 2 W/SOLID LID
STORM DRAIN MANHOLE
BEEHIVE MANHOLE
YARD DRAIN (ROUND LID)
YARD DRAIN
STORM DRAIN CLEAN —OUT
STORM DRAIN PIPE
ROOF DRAIN
SD SERVICE 6" CPEP WITH
INVERT 0 END OF PIPE
SANITARY SEWER
SANITARY
SEWER
MANHOLE
SANITARY
SEWER
CLEANOUT
SANITARY
SEWER
GRAVITY
SANITARY
SEWER
FORCE MAIN
TRAFFIC
STRAIGHT/RIGHT TURN ARROW
STRAIGHT/RIGHT TURN ARROW
LEFT/RIGHT TURN ARROW
STRAIGHT/LEFT/RIGHT TURN ARROW
LEFT TURN ARROW
RIGHT TURN ARROW
STRAIGHT ARROW
HANDICAP PARKING
BIKE LANE
TRAFFIC SIGN
INFORMATION SIGN
STREET LIGHT
— — — 820---
A J
S
FM
8215�
X
1 1
4
M
T
WETLAND FLAG
POWER POLE W/DROP LINE & LIGHT
BIKE RACK
POWER POLE W/DROP LINE, LIGHT & TRANSFORMER
DEBRIS PILE
POWER POLE W/DROP LINE & TRANSFORMER
FIRE PIT
POWER POLE W/LIGHT
BOLLARD
POWER POLE W/LIGHT & TRANSFORMER
HORSE SHOE PIT
POWER POLE
MAILBOX
POWER POLE W/TRANSFORMER
MILE POST MARKER
PAD MOUNTED TRANSFORMER
SOIL LOG
POWER VAULT/MANHOLE
SIGN
SIGNAL CONTROL BOX
SEPTIC DISTRIBUTION BOX
SIGNAL JUNCTION BOX
SANITARY SEWER STUB MARKER POST
TRAFFIC PEDESTRIAN POLE
SEPTIC VENT
TRAFFIC SIGNAL POLE
STORM PIPE INLET/OUTLET
TRAFFIC SIGNAL POLE W/LIGHT
STORM DRAIN STUB MARKER POST
FIBER OPTIC MANHOLE
ROOF DRAIN
FIBER OPTIC STUB MARKER POST
CATCH BASIN
TELEPHONE GUY ANCHOR
CABLE TV MARKER POST
TELEPHONE ANCHOR POLE
CABLE TV RISER
TELEPHONE JUNCTION BOX (UG)
SATELLITE DISH
TELEPHONE MANHOLE
LUMINAIRE W/ARM
TELEPHONE STUB MARKER POST
LUMINAIRE
TELEPHONE POLE
LANDSCAPE LIGHT
TELEPHONE RISER
YARD LIGHT (UNDER 10' TALL)
FIRE DEPT CONNECTION
GAS STUB MARKER POST
HOSE BIB
GAS VALVE
IRRIGATION CONTROL VALVE
OIL FILLER CAP
WATER MANHOLE
GUY ANCHOR
WATER STUB MARKER POST
GUY POLE
MONITORING WELL
POWER GRATE
POST INDICATOR VALVE
ELECTRICAL JUNCTION PULL/BOX
SPRINKLER HEAD
ELECTRICAL STUB MARKER POST
WATER VAULT
ELECTRICAL METER
WATER WELL
GAS
GUARD RAIL
OIL
FENCE, BOARD
POWER (BURIED)
FENCE, BARB -WIRE
POWER (AERIAL)
FENCE, CHAIN -LINK
FIBER OPTICS
FENCE, ELECTRIC
TELEPHONE (BURIED)
FENCE HOG WIRE
TELEPHONE (AERIAL)
FENCE, SPLIT RAIL
TV CABLE (BURIED)
FENCE, WIRE
TV CABLE (AERIAL)
FENCE WROUGHT IRON
CREEK OR STREAM CENTERLINE
RAILROAD TRACKS
I WETLAND WITH BUFFER STREAM WITH BUFFER
T.E.S.C.P.
SURVEY
CONSTRUCTION SEQUENCE:
CLEARING LIMITS
6
PROPOSED MONUMENT
IN CASE
FILTER FABRIC FENCE
(1)
FOUND MONUMENT IN
casE
1. THE CONTRACTOR SHALL COMPLETE THE INSTALLATION OF THE
A A
SANITARY SEWER LINES WITHIN ONLY ONE ROADWAY BLOCK AT A
CUTOFF SWALE
OoM
PROPOSED MONUMENT
(AS DEFINED)
TIME AND SHALL COMPLETE THE TEMPORARY HOT —MIX ASPHALT
RESTORATION OF EACH ROADWAY BLOCK BEFORE BEGINNING
i-—
INTERCEPTOR DITCH
OOM
FOUND MONUMENT (AS
DEFINED)
WORK IN ANOTHER BLOCK.
- —�— — —�— — N.G.P.E, FENCE
2, TEMPORARY RESTORATION OF TRENCHES FOR OVERNIGHT USE
SHALL BE ACCOMPLISHED BY USING HOT -MIX ASPHALT (HMA).
®
ROCK CHECK DAM
DELTA
STEEL PLATES MAY BE USED OVERNIGHT TO COVER THE LAST
0
SEDIMENT FILTER
(R)
RADIAL BEARING < >
SECTION OF TRENCH. STEEL PLATES MUST BE PINNED DOWN
AND ASPHALT RAMPS/WEDGES MUST BE PLACED AROUND THE
(NR)
NON -RADIAL BEARING
PLATES. STEEL PLATES SHALL NOT BE USED ON STEEP GRADES
STRAW BALE
OR WHERE STEEL PLATES PRESENT A ROADWAY HAZARD.
GRAVEL CONE
L
ARC LENGTH
JIM
RIP RAP PAD
CONSTRUCTION ENTRANCE
WARNING:
THE UTILITY LOCATIONS SHOWN
ARE APPROXIMATE ONLY. DEPTH
UNKNOWN. CALL 1-800-424-5555.
®CONSULTING E N G I N E E R S L L C
33400 8th Avenue S, Suite 205
Federal Way. WA 98003
FEDERAL Wky (253) 838-6113
www.esmcivii.com rvFRF7 4251297-99°°
Civil Engineering Land Surveying Land Planning
Public Works I Project Management I Landscape Architecture
ESM JOB # 1655-001-011
43175 �
STD
S��NAL EN��
0
FIRST SUBMITTAL
1
SECOND SUBMITTAL
2
MYLAR SUBMITTAL
3
SANITARY SEWER REIS
4
SANITARY SEWER REVISIONS
5
AS —BUILT SUBMITTAL
NO.
REVISION
ABBREVIATIONS
AVE
AVENUE
AC
ASBESTOS CEMENT PIPE
ADJ
ADJACENT
ALUM
ALUMINUM
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
AP
ANGLE POINT
ASPH
ASPHALT
ASTM
AMERICAN SOCIETY OF TESTING AND MATERIALS
ASSY
ASSEMBLY
BF
BLIND FLANGE
BLDG
BUILDING
BLK
BLOCK
BO
BLOW OFF
BOW/BW
BOTTOM OF WALL
BVC
BEGIN VERTICAL CURVE
BW
BACK OF WALK
CTR
CENTER
CB
CATCH BASIN
CI
CAST IRON
CL/(i
CENTERLINE
CLR
CLEAR
CMP
CORRUGATED METAL PIPE
CO
CLEANOUT
CONIC
CONCRETE
C
CONDUIT
CONN
CONNECTION
CONTR
CONTRACTOR
CONT
CONTINUED
CY
CUBIC YARDS
CL
CLASS
CF
CUBIC FEET
CFS
CUBIC FEET PER SECOND
DC
DEGREE OF CURVATURE
DI
DUCTILE IRON
DIA/0
DIAMETER
DOT
DEPARTMENT OF TRANSPORTATION
DIM
DIMENSION
DWGS
DRAWINGS
D
DRAIN
EOP
EDGE OF PAVEMENT
E
EAST
ELEV
ELEVATION
EL
ELEVATION
ELEC
ELECTRICAL
EVC
END VERTICAL CURVE
EXIST
EXISTING
FDC
FIRE DEPARTMENT CONNECTION
FIG
FINISH GRADE
FIG
FIGURE
FIN
FINISHED
FL/E
FLOWLINE
FL
FLANGE
FT
FEET
FM
FORCE MAIN
GA
GAUGE
GALV
GALVANIZED
GI
GALVANIZED IRON
GV
GATE VALVE
ESM
11sm
12
SURVEYED:
MMM1/122
1/24
DESIGNED:
BW
ESQ)
121
10 w 12
DRAWN:
ES
ESM
M
123�13
CHECKED:
?' I DATE I APPR APPROVED
S('A,_-.
S-362149
VERTICAL: NAVD 1988
IM HORIZONTAL: NAD 1983/1991
ONE INCH DATUM
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
GENERAL NOTES:
1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE
LATEST STANDARDS AND SPECIFICATIONS OF THE CITY OF
ID
INSIDE DIAMETER
RENTON PUBLIC WORKS DEPARTMENT AND THE 2008 EDITION OF
IE
INVERT ELEVATION
THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS
APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
IN
INCHES
RENTON STANDARD PLANS & SPECIFICATIONS. SOME STANDARD
DETAIL DRAWINGS MAY HAVE BEEN MODIFIED FOR THE CONTRACT.
L
LENGTH
THE CONTRACTOR SHALL REFER TO DETAIL DRAWINGS INCLUDED
IN THE CONTRACT DOCUMENTS. A SET OF APPROVED PLANS
LB
POUNDS
SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
LF
LINEAL FEET
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
MAX
MAXIMUM
AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
MFR
MANUFACTURER
DISTURBANCE. FOR UTILITY LOCATES CALL 800-424-5555 (OR
MH
MANHOLE
81 1) A MINIMUM OF 72 HOURS PRIOR TO EXCAVATION.
MIN
MINIMUM
3. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE
SUBMITTED AT THE PRE —CONSTRUCTION MEETING, ANY
MJ
MECHANICAL JOINT
MODIFICATIONS TO THE APPROVED TRAFFIC CONTROL PLAN SHALL
BE RESUBMITTED AND APPROVED PRIOR TO IMPLEMENTATION.
MISC
MISCELLANEOUS
N
NORTH
4. ALL FITTINGS SHALL BE BLOCKED PER CITY OF RENTON
STANDARD DETAILS UNLESS OTHERWISE NOTED.
NO
NUMBER
5. THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO
NTS
NOT TO SCALE
REMOVE DUST AND DEBRIS FROM PAVEMENT AREA AS DIRECTED
BY THE ENGINEER. FLUSHING OF STREETS SHALL NOT BE
OC
ON CENTER
PERMITTED.
OD
OUTSIDE DIAMETER
6. BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR
OHW
ORDINARY HIGH WATER
SHALL PROVIDE A CATCH BASIN FILTER FOR ALL DOWNHILL
STORM DRAIN INLETS AND CATCH BASINS. THE CONTRACTOR
PI
POINT OF INTERSECTION
SHALL PERIODICALLY INSPECT THE CONDITION OF ALL FILTERS
AND REPLACE AS NECESSARY.
PP
POWER POLE
PVI
POINT OF VERTICAL INTERSECTION
7. PAVEMENT MARKINGS (E.G. LANE LINE BUTTONS OR PAINT, STOP
BARS, CROSSWALKS, ETC.) DAMAGED OR REMOVED DURING
PE
POLYETHYLENE
CONSTRUCTION SHALL BE REPLACED IN KIND.
PERF
PERFORATED
PVC
POLYVINYL CHLORIDE
PVMT
PAVEMENT
PVT
POINT OF VERTICAL TANGENCY
PC
POINT OF CURVATURE
NOTE:
PT
POINT OF TANGENCY
QTY
QUANTITY
1. LOT LINES ARE BASED ON GIS INFORMATION AND ARE FOR
GENERAL INFORMATION ONLY.
RET
RETAINING
2. 8" SEWER FORCE MAIN SHALL BE C900 CLASS 200 PIPE
RR
RAILROAD
MATERIAL.
3. GRAVITY SANITARY SEWER PIPE MATERIAL:
R
RADIUS
0 PVC SDR35 - 4' TO 15' OF COVER - 18"o OR LESS
PVC C905 DR21 - OVER 18"0
RED
REDUCER
• PVC C900 - LESS THAN 4' OF COVER
REINF
REINFORCED
PVC C900 - OVER 15' OF COVER
REQ
REQUIRED
R/W
RIGHT OF WAY
S
SOUTH
SURVEY DATUM:
SCH
SCHEDULE
HORIZONTAL DATUM:
SD
STORM DRAIN
NAD83(91) WASHINGTON STAE PLANE COORDINATE SYSTEM NORTH
ZONE
SF
SQUARE FEET
VERTICAL DATUM:
SHT
SHEET
NAVD 1988 CITY OF RENTON PUBLISHED BENCH MARKS
SPECS
SPECIFICATIONS
#1909 CASED MONUMENT WITH LEAD AND TACK AT THE INTERSECTION
SQ
SQUARE
OF SE 139th PLACE AND 156TH AVENUE SE.
ELEVATION = 408,64
SS
SANITARY SEWER
#2088 CASE MONUMENT WITH 'X - BRASS DISC AT THE INTERSECTION
STA
STATION
SE 142ND PLACE AND 156TH AVENUE SE.
STD
STANDARD
ELEVATION = 372.34
TIC
TOP OF CURB
CITY OF RENTON PUBLISHED BENCH DESCRIPTIONS ARE REVERSED
FOR
TEL
TELEPHONE
BENCHMARKS #2088 AND # 1909
THRD
THREADED
SITE CONTROL:
THRU
THROUGH
ESM CONTROL POINT LOCATED 27' NW OF THE INTERSECTION OF SE
136TH ST AND 168TH AVENUE SE.
TOW/TW
TOP OF WALL
N 178033.9669, E 1323118.6406, ELEVATION = 466.25
TYP
TYPICAL
ESM CONTROL POINT LOCATED 511' WEST OF THE INTERSECTION OF
VERT
VERTICAL
SE 136TH ST AND 168TH AVENUE SE ON THE SOUTHERLY EDGE OF
ASPHALT.
W
WEST
N 178031,6592, E 1322625.8698, ELEVATION = 454,97
W/
WITH
W/0
WITHOUT
WSS
WATER SAMPLING STATION
CHECKED FOR COMPLIANCE TO CITY STANDARDS
RECORD
DRAWING
%
CITY O
ISSAQUAH SCHOOL DISTRICT
DATE:
04/23/201
-
FIELDBOOK:
SANITARY SEWER EXTENSION - P2
R E N TO
PAGE
DRAWING NO:
Planning/Building/Public
Works Dept.
LEGEND AND GENERAL NOTES
LG-01
SHEET: OF:
1
m00
7�
Y
b
t"
x ~�
�mzCD
as `�
1
o
x
y
Z
D
0