Loading...
HomeMy WebLinkAboutWWP2703621.80w Co Q z z w 0 O 0 `n z UJ F_ X LU Ir LU LU U) F_ U_ 0 J O O CU -17 C1 Q {n U) PID # 4306500050 HOUSE #16234 FIRST FLOOR ELEV.=488.18 r m Z N Cal = 50' R/W I rn :-i FL D V) CO 0 0 -P PID #4306500060 HOUSE #16240 FIRST FLOOR ELEV.=482.87 73 L.F. 10"0 PVC C900 0 S=1 .34% A PORTION OF SEC 13114 & 243 TWP 23 N, RGE 5 E, WM, KING CO, WA EXISTING DRAINFIELD 15' CITY OF RENTON S.S.M.H. P2-08, TYPE 1-60"0 SANITARY EASEMENT SEWER n jy STA. 400+00.00 �� NOTE: STA. 905+38.96, SE 137TH PL = STA. 905+94.53, 16.74' LT. 1 2 � S.E. 137TH PL. IS A CITY OF RENTON STREET N: 177606.48 N: 177621.35 APPROXIMATE LOCATION y ALL TRENCH RESTORATION SHALL BE PER CITY E: 1321701.28 E: 1321757.39 OF S.S.F.M. SANITARY t�� SEWER FORCE MAIN TO OF RENTON CURRENT TRENCH RESTORATION SEE DETAIL SHEET SS-06 / AND STREET OVERLAY DETAIL. PER SECTION BE FIELD LOCATED BY 010* � 7.1.D REQUIREMENT FOR PATCHING, OVERLAY, __._ CONTRACTOR AND ESM � i OVERLAY WIDTHS) IF THE OUTSIDE OF THE FORCE MAIN CROSSES CONNECTION / / 00.. Oct TRENCHING IS WITHIN THREE FEET (3') OF ANY `�h`L��� TO EXISTING DRAINFIELD. LOCATION / X ADJACENT LANE LINE, THE ENTIRE ADJACENT UNKNOWN. CONTRACTOR TO VERIFY / 00 TRAVELED LANE AFFECTED WILL BE REPAVED. LOCATION AND ELEVATION PRIOR TO •O CONSTRUCTION. / STA. 401 +36.83 O N: 177632.41 / E: 1321859 EXISTING CHAIN LINK FENCE (TYP) S 64' 13'23" E / 1-8" 45' BEND (MJXMJ) (ISSAQUAH SCHOOL DISTRICT 16.14' o / 1-CONC. BLOCKING PROPERTY TO THE NORTH OF o 8"0 PVC C900 THE FENCE) ' S.S.F.M. 1 h / REMOVE EXISTING TREE. 4 X 1 NO TREES ALLOWED IN EDGE OF o PROPOSED SANITARY to rn SEWER EASEMENT CLEARING LIMITS CITY OF RENTON (TYP ) POND TRACT 3 -+ PID #4306500130 0 STA. 400+89.62 CENTER OF CUL-DE-SAC 117• N: 177589.87 b E: 1321838.53 O �ry N 77'31'55 0 1-8" 45' BEND (MJXMJ) W 62.39' 0 1-CONC. BLOCKING O 0 `�' 0 STA. 400+79.88 N: 177586.65 S.S.M.H. #P2-07, TYPE 1-48"0 3 S 89'39'03" E _< 7 E: 1321829.33 STA. 905+25.53, 8.00' RT. w 14.87' O Z 1-8" 45' BEND (MJXMJ) LIBERTY N: 177598.94 n °' TRAIL EASEMENT RECORDING '1-GONG. BLOCKING-n E: 1321687.59 N oo PID #4306500070 NO. 20070605001667/ CHAIN LINK FENCE HIGH SCHOOL PID #4306500080 0 HOUSE #16241 PROPOSED SS EASEMENT m O AT PROPERTY LINE PID #1323059038 FIRST FLOOR ELEV.=480.98 HOUSE #16235 V � Z 4' HIGH ROCKERY FIRST FLOOR ELEV.=483.34 O TOE-469.6 SE 137TH PL (LIBERTY LANE) - CITY OF RENTON Z 495 OO 490 C; d- �' 0o1 485 cn Q Vi w N 480 LLjZ_ w J w V) U 475 Q 470 465 J Of J c0 r i� a0 0 w N r- � 00 0 Ili 0000. � a M 't w EXISTING GROUND � r rn� ® ROAD ow ow ow Loom 0� U) w Q Q Q Q - 0w (~nw V)w V)w N 18" MIN. VERTICAL CLEARANCE + w + w BETWEEN S.S.F.M. AND WATER 03 0 om 0 0 U X.Ww V)w S.S.M.H. #P2-07. TYPE 1-48"0 STA. 905+34.16, 8.00' RT. N:177598.94 E:1321687.59 RIM = 484.66 I.E. IN = 473.60, 10" 0 I.E. OUT = 473.50, 10"0 904+40 904+80 WARNING: THE UTILITY LOCATIONS SHOWN ARE APPROXIMATE ONLY. DEPTH UNKNOWN. CALL 1-800-424-5555. 905+20 73 L.F.> 10"0 C900 S.S. ® S=1.34% S.S.M.H. #P2-08. TYPE 1-60" STA. 905+94.53, 16.74' LT. = STA. 400+00.00 N:177621.35 E:1321757.39 RIM = 483.89 I.E. = 474.58, 10"0 SEE DETAIL SHEET SS-06 905+60 495 490 = cc a 485 J O Ir 480 w V) O Q 475 H O U 470 Ix O 465 485 tZ 480 J a J 475 O Ir CL w 470 V) O = 465 H O U Ix 460 O 470 BEND 8"0 FORCE MAIN PER MANUFACTURER'S RECOMMENDATIONS (190' MIN) WITH MAX DEFLECTION AT JOINT HALF OF THAT ALLOWED BY THE MANUFACTURER (LESS THAN 1') n P`) z Cd +m in 0It LiJ U) 00 EXISTING GROUND _ ® PIPE 8"0 PVC C900 S.S.F.M. \ 3.0' COVER ol MINIMUM (TYPICAL) N` 8" FORCE MAIN TO BE CONSTRUCTED WITH A Ll\ POSITIVE S=0.50%. HIGH POINT OF THE FORCE MAIN LOCATED AT THE 00 N `) z AIR -VAC ASSEMBLY. 00 ►� `U N �� D 3 MAXIMUM CROWN OF PIPE r` 0 N 0) 0�t z 00 z +�0 = 475.25 �+mr0+wd� 0Y ♦� \ �0 'tU)D 0 � II . H w L'- 'X V � V) 00 S.S.M.H. #P2-08, TYPE 1-60"0 `IN,� SEE PROFILE AT LEFT 400+00 400+40 401 +20 485 4800 O 475 ± O 01 �cn . V) 470 ~ V) _ LMJ V) Z_ w J V) 465 = Q 460 470 401 +60 n SCALE: 1"=20' HORIZ. 1 "=5' VERT. CONTOUR INTERVAL = 2' 20 10 0 20 40 NOTES: 1. EXISTING UTILITIES ARE SURFACE LOCATED ONLY. CONTRACTOR TO VERIFY LOCATION AND ELEVATION PRIOR TO CONSTRUCTION. 2. FOR TRENCH SECTION AND PAVEMENT RESTORATION SEE ROADWAY RESTORATION SHEET DT-01. 3. FINAL RIM ELEVATIONS SHALL MATCH RESTORED PAVEMENT GRADES. 1AJ BRIARWOOD ELEMENTARY SCHOOL Q u� Q = 0 8 SE 136TH ST Jt i SE 137TH ,PPIL r� ❑ V) LIBERTY HIGH a SCHOOL CD _J L-i L. r 1r-1 r--- SE 144TH ST MAYWOOD MIDDLE SCHOOL 0 KEY MAP NOT TO SCALE S=3 62 180 CHECKED FO COMPLIANCE TO CITY STANDARDS SURVEYED: SCALE: DATE: vwE CONSULTING ENGINEERS LLC` tied % Fl SV�� ESM 12/08/11 VERTICAL NAVD ,9B8 ISSAQUAH SCHOOL DISTRICT / 1/ 181 S 333rd Street / Ms • HORIZONTAL: NAD 1983/1991 t► Q f ® ( I I SECOND SUBMITTAI- ESM 1 O4/ �� DESIGNED: �V �I >_.- CITY 0 E Bldg C, Suite 210 � EIELDBOOK: Federal Way, WA98003 2 MYLAR SUBMI1TAL ESM 1/11/12 am SANITARY SEWER EXTEN I - 2 FEDEML WAY (253) 836-9900 R E N T O N www.esmcivil.com EVEREI-I (426) 297-9900 DRAWN: PAGE: EU.ENSBURG (509) 962-2608 DRAWING N0: Civil Engineering Land Surveying Land Planning �Q ,(Q� ONE INCH DATUM Public Works I Project Management I Landscape Architecture SL CHECKE� AT FULL SCALE Planning/Building/Public Works Dept. PLAN AND PROFILE: S.E. 137TH ST. SS-02 IF NOT ONE INCH ESM JOB # 1655-001-01 1 1 11 NO. REVISION Pv DATE APPR APPROVED: IF ACCORDINGLY STA 904+40.00 TO FORCE MAIN STA 401 +60.00 SHEET: 6 OF:1 t�7 H M z , z� x � N 0 C Or Q�d x y Vim' O r