HomeMy WebLinkAboutWWP2703625.12ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURES/DEVICES �\ CIRCUIT BREAKER XXX/YY - CB SIZE & NO. OF POLES SERVICE ENTRANCE, O FLUORESCENT FIXTURE ET -ELECTRONIC TRIP SWITCHGEAR, MOTOR CONTROL TM - THERMAL MAGNETIC BREAKER CENTER, OR PANELBOARD MCP - MOTOR CIRCUIT PROTECTOR SURFACE MOUNTED WALUCEILING MOUNTED FIXTURE SE - SERVICE ENTRANCE PANELBOARD GFI - GROUND FAULT INTERRUPTER FUSE FLUSHED MOUNTED EMERGENCY LIGHT WITH SELF ---° FUSED DISCONNECT SWITCH PANELBOARD ® CONTAINED BATTERY ��--- PLUG-IN CONNECTION SURFACE OR PENDANT MOUNTED RTM RUN TIME METER • NXX FIELD CONTROL STATION WITH NEMA O FIXTURE ❑ REQUIREMENTS. OC MOTOR OPERATION COUNTER N1 - NEMA 1 O RECESSED FIXTURE N3R - NEMA 3R SSRVS N4 - NEMA 4 Mp MOTION DETECTOR SSRVS - SOLID STATE N4SS - NEMA 4 STAINLESS STEEL REDUCED VOLTAGE N4F - NEMA 4 FIBERGLASS pC PHOTO CONTROL CELL STARTER N6 - NEMA 6 N12 - NEMA 12 GASKETED SWITCH OUTLETS VARIABLE FREQUENCY DRIVE S •�, EQUIPMENT MOUNTING STAND ® STANDARD SWITCH, 120VAC, 20 AMP MOTOR STARTER T 3 ®SWAY3-WAY SWITCH, 120VAC, 20 AMP HEATER, WATTAGE NOTED A B MOTOR STARTER W/ OPERATOR S ® 3-POSITION SWITCH, 120VAC, 20 C D DEVICES HOA HOA AMP, LABEL SWITCH POSITION A - HAND -OFF -AUTO EQUIPMENT CONNECTION HAND -OFF -MOTION OR PHOTO B -OPERATIONAL COUNTER C - RUN TIME METER SINGLE PHASE MOTOR. DEE SINGLE -POLE F PILOT -LIGHTED D - RUN LIGHT M HORSEPOWER AS NOTED S DOUBLE -POLE S KEY -OPERATED E - FAIL LIGHT 2 F - EMERGENCY STOP THREE PHASE MOTOR. 3 THREE WAY S V LOW VOLTAGE 100 KIRK KEY INTERLOCK HORSEPOWER AS S FOUR WAY S MASTER KO NOTED 4 M POWER TRANSFORMER S DIMMER PUSHBUTTON HP SINGLE PHASE MOTOR. D M CONTROL POWER TRANSFORMER HORSEPOWER AS FIRE SYSTEM SYMBOLS NOTED GE ELECTRICAL PLUG < HEAT DETECTOR TRANSFORMER SMOKE DETECTOR DISCONNECT SWITCH CURRENT TRANSFORMER ❑D FIRE ALARM DISPATCH STROBE ALARM VOLTAGE TRANSFORMER FUSED DISCONNECT SWITCH RA FIRE ALARM AUDIBLENISUAL ALARM -3 �- COMBINATION MOTOR 0 FIRE ALARM MANUAL PULL STATION � CONTACTOR STARTER AND DISCONNECT ADDITIONAL SYMBOLS CAPACITOR SWITCH O SOUND SYSTEM SPEAKER ENGINE GENERATOR SOUND SYSTEM VOLUME CONTROL GENERATOR CONNECTION �B DOORBELL RECEPTACLE VALVE SYMBOLS S SOLID NEUTRAL RECEPTACLES AND JUNCTION BOX SYMBOLS PILOT VALVE SOLENOID N OJ CEILING JUNCTION BOX TB TERMINAL BLOCK I--Q WALL JUNCTION BOX VALVE SURGE PROTECTION DEVICE J� FLOOR JUNCTION BOX SPD KD DUPLEX WALL RECEPTACLE ,120V I I CHECK VALVE a o SURGE PROTECTION DEVICE Wp -WEATHERPROOF (ALTERNATIVE) G = GROUNDED GROUNDING SYSTEM SYMBOLS IG = ISOLATED GROUND GF =GROUND FAULT INTERRUPTER I ( CONTROL VALVE 1 GROUND DOUBLE DUPLEX ELECTRICAL SITE PLAN SYMBOLS METAL PIPE GROUND KO SINGLE RECEPTACLE, 120V UTILITY POLE AND GUY WIRE CONNECTION POINT, EXOTHERMIC WELD. CADWELD OR APPROVED � SINGLE RECEPTACLE, 208V HH MANHOLE OR HANDHOLE EQUAL. ® DUPLEX FLOOR RECEPTACLE,120V © BURIED POWER VAULT OR MANHOLE GROUND ROD SIZED PER N.E.C. T TELEPHONE VAULT OR PEDESTAL USE EXOTHERMIC WELD � SPECIAL PURPOSE WALL CONNECTION AT THE GROUND ROD. RECEPTACLE, RATING AS NOTED O KD CLOCK FIBER OPTICS VAULT OR PEDESTAL PIGTAIL, BARE COPPER, LENGTH AS a O- LUMINAIRE REQUIRED, F MINIMUM. TELEVISION ♦ CONNECTION POINT, MECHANICAL, I I' PAD -MOUNT TRANSFORMER COMPRESSION TYPE. / TELEPHONE TELEPHONE/DATA WITH CABLE ROAD ABBREVIATIONS SPDT - SINGLE POLE, DOUBLE THROW SPST - SINGLE POLE, SINGLE THROW DPST - DOUBLE POLE, SINGLE THROW WP - WEATHER-PROOF GFI - GROUND FAULT INTERRUPT P - POWER C - CONTROL J - INSTRUMENTATION PC - POWER & CONTROL CJ - CONTROL & INSTRUMENTATION CKT. - CIRCUIT C.O. - CONDUIT ONLY N.L. - NIGHT LIGHT AL. - ALUMINUM CU. - COPPER HOA HAND -OFF -AUTO SWITCH ETM RUN TIME METER OC OPERATION COUNTER MRIL MOTOR RUN INDICATION LIGHT SFIL SEAL FAIL INDICATION LIGHT SFTR SEAL FAIL TRIP RESET OTIL OVER TEMPERATURE INDICATION LIGHT MOIL LADDER LOGIC SYMBOL LEGEND INDICATOR LIGHT INDICATOR LIGHT RELAY A - AMBER G - GREEN xYz B - BLUE R - RED �2s C - CLEAR W - WHITE RELAY TR - Timed relay CR - Control relay LIMIT SWITCH FLOAT SWITCH O LIMIT SWITCH, NORMALLY OPEN O FLOAT SWITCH, NORMALLY OPEN LIMIT SWITCH FLOAT SWITCH LIMIT SWITCH, NORMALLY CLOSED O-- FLOAT SWITCH, NORMALLY CLOSED TIME DELAY CONTACT PUSHBUTTON O TIME DELAY CONTACT, NORMALLY OPEN, TIME TO CLOSE LNORMALLY PUSHBUTTON, CLOSED TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY PUSHBUTTON L_ PUSHBUTTON, NORMALLY OPEN ___ CLOSED, TIME TO OPEN _J O O MOTOR OVERLOAD INDICATION LIGHT TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY O OPEN, TIME TO OPEN INDICATE TYPE BY INSTRUMENT METER LETTER A - AMMETER VAR - VARMETER TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY V AH - AMPERE -HOUR VARH - VARHOUR METER0-17CLOSED, PF - POWER FACTOR W - WATTMETER TIME TO CLOSE V - VOLTMETER WH - WATTHOUR METER AM VA - VOLT AMMETER RELAY CONTACT, NC -j+- RELAY CONTACT, NO RELAY CONTACT, INSTANTANEOUS CHANGE RACEWAY LEGEND SIi� i'Lf�N � ���N�' P PROPOSED POWER PRESSURE SWITCH TEL PROPOSED TELEPHONE O PRESSURE SWITCH, NORMALLY OPEN TELM PROPOSED INSTRUMENTATION Fo PROPOSED FIBER OPTICS 1�01_0/NG OP F,AG8-P ?CLAN 1-ff6fND EXPOSED RACEWAY CONCEALED, UNDERGROUND, EMBEDDED, OR CONCRETE ENCASED RACEWAY HOME RUN TO PANELBOARD OR AS INDICATED C CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTED FLEXIBLE CONDUIT CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS CALLOUT INDICATING CONDUIT SIZE, Y2- GRC, 2-#12 NUMBER AND SIZE OF WIRE. CALLOUT INDICATING CONDUIT PER XXX SCHEDULE 0 CONDUIT BENT UP OR TOWARD CONDUIT BENT DOWN OR AWAY I CAPPED CONDUIT ELECTRICAL & SIGNAL PLAN DEVICES SV SOLENOID VALVE COIL ZS INTRUSION SWITCH MV MOTORIZED VALVE COIL MD MOTION DETECTOR OMOTOR LT LEVEL TRANSDUCER FS FLOOD SWITCH HE HEATING ELEMENT LS LIMIT SWITCH PS PRESSURE SWITCH PB PANIC BUTTON PE PRESSURE ELEMENT T O THERMOSTAT SWITCH FE FLOW ELEMENT ZS EY INTRUSION SWITCH - KEY AE ANALYSIS ELEMENT THERMOSTAT THERMOSTAT SWITCH, O NORMALLY OPEN THERMOSTAT THERMOSTAT SWITCH, NORMALLY CLOSED FLOWSWITCH O FLOWSWITCH, NORMALLY OPEN FLOWSWITCH FLOWSWITCH, NORMALLY CLOSED PRESSURE SWITCH PRESSURE SWITCH, 2 POLE SWITCH NORMALLY CLOSED I ` 3 POLE SWITCH I — 0 GENERAL NOTES 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL APPEAR IN THIS SET OF PLANS, 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS. 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER. REVISED TO CONFORM TO CONSTRUCTION RECORDS C RH2FENGINEERINGOOTINC. DA Q � se � 9° co � x 00 M o ° ep U N Zo a o CV z_g W ^ W w a� Jo Z D W ci W, 2£ pN N a Z W a W J J Q U W J W SCALE: SHOWN 01 i DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO SHEET NO E01 14 W IW >I m �I 0 zl 21 r o oz u, _-F z D= C o 0 0 n- n M z M z z cn 0 D D T 7 0 �o D C3 C n —4 D � A 0 D z rr A = nC) O n r" n� n uz z M O D I z z lot K >UQ z 1 N 7 7 z