HomeMy WebLinkAboutWWP2703625.60) a 0 o' I Z 0 F Q cn LL J I T N I z 0 z W D_ 0 0 Q U / 0 0 / > U Q / 0 Q U Q / c 0 0 U Q C Q) 0 0 a Q 0 0 N 0 0 0 Ln 0 0 / N U 0 / N 0 0 N / Lv Q z W J LL RT 0 N z 0 Cn Li > BACKUP LEVEL CONTROL DISPLACEMENT - FLOATS W/15' EXTRA COIL FOR LEVEL ADJUSTMENT (3 TOTAL) SEE ELECTRICAL DRAWINGS SUBMERSIBLE PUMPS SEE SPECS. ° (2—REQ'D.) 96"0 WET WELL 0 0 L__ I II C I ; Inv FRP ACCESS LADDER WITH POLYPROPYLENE HANGING LADDER BELOW. DOOR ° a I I i — — —\ OPEN °I I I I 5 STILL WELL I I 9 PER DETAIL I I I ° I 4" PVC VENT II— — ---- --- — PIPE PER DETAIL — — — — — — — 5 S.S. BRACKET ° FOR STILL WELL 2 _ NEW 1 EX. 12" STORM Y STORM PIPE CB �_---- 13 1' u TYP. 13 12 ° ° 1' 3 a° — ° - - ------ 110 I I � it a I I 14 II I CUT NOTCH IN GRATING i 1 1 11 I AND DRAIN DISCHARGE 1" BELOW GRATING III r i III DOORS I I I SUMP W/ ALUMINUM i j I OPEN GRATE 8 I I I I 11 9 I I I I 4 I I I I II 2 I 1 1 I I I I 14 I II 10 I II I I I - - - -- I o 48"x72" ACCESS HATCH ° ------ - 10 -- PER SPECIFICATIONS ° 6'-0" 11 2 2" PVC, SCH. 40 ACCESS — — — — — — — — — — _— _— HATCH DRAIN LINE. 14 r — — — — — — I II I I I I HINGES ON THIS ILiIII 2 SIDE OF HATCH -- —— — — —— -- I 24"x36" SINGLE ACCESS 4A 4° HATCH WITH POST & CHAIN ° ° HATCH GUARD PER la SPECIFICATIONS n ° EXTRA HEAVY DUTY ALUMINUM ACCESS LADDER. 6" DI FORCE MAIN — (SEE SHT. C5 & C6) PLAN VIEW O 4'x6' ALUMINUM DOUBLE DOOR ACCESS HATCH, PER SPECS WITH RAILING AND CHAIN HATCH GUARD. UNI—HOIST WALL MOUNTED SLEEVE PER SPECS. (TYP. OF 3) COORDINATE LOCATIONS WITH CITY l 0 2t �_ w�� 8" DI GRAVITY SEWER INLET II I -- I i I I `PIPE PENETRATION (TYP.) I (SEE NOTE 4 THIS SHEET) I I I III 2"0 TYPE 304 SCH.40 S.S. GUIDE RAILS (TYP.) —MIXED FLUSH VALVE ROTATE UP AT 45' ANGLE �R A1N NEW 12" SBAN p�p1N0i OVER FORCE PIPE PENETRATION (TYP.) (SEE NOTE 4 THIS SHEET) —1-1/2" SCH. 80 PVC SUMP PUMP DISCHARGE PIPE PRESSURE GAUGE ASS' (TYP. OF 2) 7" FLOOR " DRAIN 24" 18" 12" 6" 0 1' 2' 3' 4' i% SCALE: 1 /2"=V-0" Stantec 11130 NE 33rd Place, Bellevue WA 98004 phone: (425) 869-9448 www.stantec.com 4'x6' ALUMINUM DOUBLE DOOR ACCESS HATCH, PER SPECS WITH RAILING AND CHAIN HATCH GUARD. 1LF-6" SPOOL (FLxFL) 1-2" TAPPED BLIND FLANGE 1-2" BALL VALVE PRE —CAST CONCRETE VALVE VAULT 6'W x 121, UTILITY VAULT N0. 612—LA PRO) L► ,7 �'SIO.'�"11L V•"'� � PRE —CAST CONCRETE VALVE VAULT 6'W x 121, UTILITY VAULT NO. 612—LA 24%36" SINGLE ACCESS HATCH WITH POST & CHAIN HATCH GUARD PER SPECIFICATIONS VALVE NUT EXTENDER SET LID FLUSH WITH & VALVE BOX PER PAVEMENT. SEE SHT.C10 DETAIL FOR PAVEMENT DETAILS 27 52' ja 4a `a • •a FM IE=20.14' 4" CRUSHED SURFACING BASE COURSE COMPACTED TO 95% MDD PER ASTM D1557 42"-45" 0 14 of 1LF-6" SPOOL (FLxFL) o1-6" TAPPED BLIND FLANGE W/2" TAP 1-2" BALL VALVE EXTRA HEAVY DUTY ALUMINUM ACCESS o LADDER 0 o 12'-0" ma _ EXTEND 1' (MIN) BEYOND CONCRETE BASE L24" QUARRY SPACES BASE COURSE COMPACTED TO 95% MDD PER ASTM D1557 MATERIAL LIST ITEM DESCRIPTION QTY. 1 6" D.I. PIPE SPOOL, FL x FL, LF AS NEEDED 2 6" D.I. PIPE SPOOL, FL x PE, LF AS REQ'D. 8 I 3 6" D.I. PIPE SPOOL, PE x PE, LF AS REQ'D. 2 4 6" 90' BEND, FL x FL 1 5 6" 90' LONG RADIUS BEND, FL x FL 2 6 6" TEE, FL x FL 1 7 4% 6" REDUCER, FL x FL 2 8 6" CHECK VALVE, FL X FL, PER SPECS. 2 9 6" RESILIENT WEDGE GATE VALVE, FL X FL, PER SPECS. 2 10 6" RESTRAINED FL. CPLG. ADAPTER 7 11 ADJUSTABLE PIPE STAND, PER DETAIL 3/C9 & SPECS. 4 12 CONCRETE SUPPORT BLOCK 3 13 RETAINER GLAND, SIZE AS NEEDED 5 14 STAINLESS STEEL STRAP, SIZE AS NEEDED 8 15 6" MAGNETIC FLOW METER, PER SPECS. 1 16 6" ROMAC STYLE 501 FLEX CPLG. W/ ROMAC 611 SERIES RESTRAINT SYSTEM 3 17 8" ROMAC STYLE 501 FLEX CPLG. 1 18 8" D.I. PIPE SPOOL, FL x FL, LF AS SHOWN 1 19 8" D.I. PIPE SPOOL, FL x PE, LF AS REO'D. 2 j 20 8" TEE, FL x FL 1 21 8" RESILIENT WEDGE GATE VALVE, FL X FL, PER SPECS. 1 22 6" 45' BEND, FL x FL 1 23 6"x6" WYE, FL x FL 1 j 24 6" RESILIENT WEDGE GATE VALVE, MJ X MJ 1 25 6" 45' BEND, MJ x FL 2 THESE CONSTRUCTION RECORD DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. STANTEC HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE INCORPORATED HEREIN AS A RESULT. REVISION SURVEYED: DESIGNED DRAWN: BWM CHECKED: BY DATE APPR APPROVED: RAILING AND CHAIN HATCH GUARD PER SPECS. V 'x6' ALUMINUM DOUBLE ACCESS 4'x6' ALUMINUM DOUBLE DOOR ATCH, PER SPECIFICATIONS ACCESS HATCH, PER SPECIFICATIONS 42"- 45" 2"PVC, SCH. 40 TEE. CONTRACTOR SHALL ASSURE TEE IS LOW POINT IN HORIZONTAL DRAIN LINE. HATCH DRAIN--\ 27.47' 2" 0 TYPE 304 SCH.40 6 14 S.S. GUIDE RAILS 11 IL 77 1-1 /2"PVC, SCH. 80 2"PVC, SCH. 40 14 SUMP PUMP 14 ACCESS HATCH DISCHARGE FROM DRAIN LINE. VALVE VAULT 3 SCH. 80 PVC SUMP PUMP - DISCHARGE PIP�23OC 14 NEW 12" STORM DRAIN PIPE *i 9 14 12 8 RAILING AND CHAIN HATCH GUARD PER SPECS. ° 4 p° � e o 7.38' VALVE NUT EXTENDER & VALVE BOX PER DETAIL 8' INSIDE DIAMETER PRECAST CONCRETE MANHOLE BACKUP LEVEL CONTROL DISPLACEMENT FLOATS W/ 15' EXTRA COIL LEVEL THESE CONSTRUCTION RECORD DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. STANTEC HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE INCORPORATED HEREIN AS A RESULT. REVISION SURVEYED: DESIGNED DRAWN: BWM CHECKED: BY DATE APPR APPROVED: RAILING AND CHAIN HATCH GUARD PER SPECS. V 'x6' ALUMINUM DOUBLE ACCESS 4'x6' ALUMINUM DOUBLE DOOR ATCH, PER SPECIFICATIONS ACCESS HATCH, PER SPECIFICATIONS 42"- 45" 2"PVC, SCH. 40 TEE. CONTRACTOR SHALL ASSURE TEE IS LOW POINT IN HORIZONTAL DRAIN LINE. HATCH DRAIN--\ 27.47' 2" 0 TYPE 304 SCH.40 6 14 S.S. GUIDE RAILS 11 IL 77 1-1 /2"PVC, SCH. 80 2"PVC, SCH. 40 14 SUMP PUMP 14 ACCESS HATCH DISCHARGE FROM DRAIN LINE. VALVE VAULT 3 SCH. 80 PVC SUMP PUMP - DISCHARGE PIP�23OC 14 NEW 12" STORM DRAIN PIPE *i 9 14 12 8 RAILING AND CHAIN HATCH GUARD PER SPECS. ° 4 p° � e o 7.38' VALVE NUT EXTENDER & VALVE BOX PER DETAIL 8' INSIDE DIAMETER PRECAST CONCRETE MANHOLE BACKUP LEVEL CONTROL DISPLACEMENT FLOATS W/ 15' EXTRA COIL LEVEL 7.38' VALVE NUT EXTENDER & VALVE BOX PER DETAIL 8' INSIDE DIAMETER PRECAST CONCRETE MANHOLE BACKUP LEVEL CONTROL DISPLACEMENT FLOATS W/ 15' EXTRA COIL LEVEL t_) COURSE COMPACTED TO 95% MDD PER ASTM D1557 SUBMERSIBLE PUMPS (2—REQ D.) NOTE: FITTINGS AND VALVES SHOWN SHALL BE THE SAME FOR BOTH DISCHARGE MAINS. EXTEND 1' (MIN) BEYOND L 12" QUARRY SPALLS BASE INSTALL FLYGT MODEL TOP 150 FIGERGLASS CONCRETE BASE COURSE COMPACTED TO 95% BASIN WITH INTEGRAL DISCHARGE ELBOWS, PER MDD PER ASTM D1557 MANUFACTURER'S INSTALLATION INSTRUCTIONS. FILL VOIDS AROUND FIBERGLASS INSERT WITH SELF -COMPACTING CONCRETE, CLASS C30 SECTION A -A NOTE: THE GRAVITY SEWER INLET PIPING (ITEMS 17 THRU 21) ARE SHOWN ROTATED 90" IN THIS SECTION FOR CLARITY. SEE PLAN VIEW FOR THE ACTUAL ORIENTATION. NOTES. 4. ALL PIPE PENETRATIONS IN WET WELL AND VALVE VAULT SHALL USE LINK SEALS UNLESS OTHERWISE APPROVED. 1. ALL DUCTILE IRON PIPING AND FITTINGS SHALL BE CEMENT KOR—N—SEAL BOOTS SHALL BE USED FOR PIPE PENETRATIONS LINED CLASS 52 EXCEPT FOR FLANGED SPOOLS (CL. 53) OR 1N MANHOLES. ALL PENETRATIONS SHALL BE MADE WHERE OTHERWISE NOTED ON DRAWINGS. ALL DI PIPING AND WATERTIGHT. FITTINGS WITHIN WET WELL SHALL HAVE EPDXY COATED 5. ALL MECHANICAL JOINT FITTINGS SHALL BE RESTRAINED EXTERIOR PER SPECIFICATIONS. w/MEGALUGS COMPATIBLE WITH DI AND PVC C900 PIPE. 2. BACKFILL AROUND STRUCTURES AND WITHIN 5' OF STRUCTURES 6. WET WELL &VALVE VAULT SHALL BE COATED INTERNALLY AND SHALL BE IMPORTED GRAVEL BORROW COMPACTED TO 95% MDD EXTERNALLY PER SPECIFICATIONS. PER ASTM D1557. THE PAY LIMITS FOR LIFT STATION EXCAVATION AND BACKFILL SHALL BE WITHIN 5' HORIZONTALLY 7. CORE DRILL ELECTRICAL & TELEMETRY PENETRATIONS IN OF THE WET WELL AND VALVE VAULT STRUCTURES. FIELD AS REQUIRED. 3. ALL CONCRETE SUPPORTS TO BE FORMED. 8. SOME ITEMS IN THE SECTION VIEW ARE ROTATED FOR CLARITY PURPOSES. SEE PLAN VIEW FOR ACTUAL ORIENTATION. SCALE VERTICHORIZONTAL NADVD 918938� 99 ,/ AS NOTED 9� ,� CITY 0 F REN TON ONE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY DATE: RENTON AIRPORT 8/6/13 LIFT STATION REPLACEMENT FIELDBOOK PAGE: DRAWING NO: LIFT STATION PLAN AND SECTION CS SHEET OF 8 21 W j � • 4T �z G) m -I�" UK m Iu z rTl m 0 D D 0 0 o 0 Do C D � _• D �z m 0 m 7 (51 ru m- "' z z m CO D CD 30 C> G ^^z YJ C co m m Y G '77 CD N 0 C)0z� > rn N D m 0 0 7 Io �C D /