Loading...
HomeMy WebLinkAboutWWP2703625.7+T 3 -o Vi J 0 (/7 I I N I i z O z W 0 0 Q 0 / 0 ry / v U L Q Q U Q i C 0 L 0 a Q Cn Q 0 0 Cv 0 0 0 / �-1 0 0 / 0 U U N 0 0 N z >, HORIZONTAL BEND TEE VERTICAL BEND V LI"V tlf\ , LUG PLUGGED END FOR VALVE ANCHOR OFFSET -1 "BARS NOTES: PLUGGED TEE / J\/ aD PLUGGED CROSS / D / PLUGGED CROSS 1. ALL CONCRETE FOR BLOCKING SHALL BE FIFE (5) SACK MIX. 2. ALL BLOCKING SHALL BE POURED AGAINST FIRM, UNDISTURBED EARTH. CONCRETE BLOCKING DETAIL N TS RETURN BEND W/ INSECT SCREEN 4" SCH. 80 PVC DUCTING\ VARIES a d PIPE PENETRATION SHALL USE KOR—N—SEAL BOOTS OR SAND COLLARS 2 VENT DETAIL C9 N TS INSTALL POWER CORD PER PRESSURE GAUGE (DIAL 41/2" FLOAT SWITCH ATTACHMENT MIN. DIAMETER) (GAUGED MOUNTED FACE UP) DETAIL IN ELECTRICAL DRAWINGS BOURDON TUBE AND CASE FILLED WITH GLYCERIN �� BRAIDED SLEEVING 45° BEND PER FLOAT SWITCH ATTACHMENT �DIAPHRAGM SEAL DETAIL IN ELECTRICAL DRAWINGS AIR BLEED EL=17.15 QUICK —CONNECT FOR PORTABLE UNITS STILL WELL ATTACHED TO FORCE MAIN PIPING WITH BRACKET —VALVE SPRING —LOADED (AUTOMATIC SHUT—OFF) 10'-2" 0 PVC D3034 1/2" S.S. PIPE SIDE MOUNTING TO EXCLUDE SUBMERSIBLE LEVEL SENSOR AIR, GRIT OR SCUM SUSPENDED PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE 'h" BALL VALVE MOUNTING BRACKET ON LEVEL SENSOR OR ATTACHING S.S. CABLE. EL=8.55 PIPE SADDLE (WELD OR STRAP TO PIPE WITH EL=8.05 =,;, 6.75 STAINLESS STEEL STRAPS) r5 STILL WELL DETAIL PRESSURE GAUGE ASSEMBLY NTS N TS Stantec 11130 NE 33rd Place, Bellevue WA 98004 phone: (425) 869-9448 www.stantec.com &A 4 C Q 6 i � IONAi. W��s.• - f-Y♦y N0. REVISION NOTE: HOT DIP GALVANIZE ASSY. AFTER WELDING FOUR TOTAL 1 /2" HILTI KWIK—BOLT STUD ANCHORS 37MIN 41 �Q a a Q N TS ADJUSTABLE PIPE SADDLE SIZE AS REQUIRED KED TO PREVENT 'ARATION 3" SCH.80 IRON PIPE 1 /4"V 8"x8"1/4" STEEL PLATE, GALVANIZED Q Q 4 Q Q. G II MOUNTING BRACKET VBOLT TO ACCESS WAY I'i PER MANUFACTURER, o PER MANUFACTURERS I I TYP. 0 6'-0" MAX. RECOMMENDATIONS. 00 I I SPACING I 0 1;j _ C I I _ V) Q I o N I I o y a Q� I I 0 a O � Ln I I I o a � Y2"0 SS THREADED ROD, EMBED 4Y4" W/ EPDXY w 1 "0 RUNGS (TYP.) IN WET WELL WITH NON —SLIP FINISH o FIXED FRP LADDER DETAILS -� SURVEYED: DESIGNED: ELB/BWM DRAWN: BWM CHECKED: BY DATE APPR APPROVED: A e , a A SECTION B-B N TS SECTION A -A N TS WET WELL CHANNELING DETAIL Ni= S 362507 SCALE: VERTICAL: NAVD 1988 AS NOTED HORIZONTAL: NAD 1983/1991 :� C TY 0 �� ML RENTON ONE INCH DATU M AT FULL SCALE Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY THESE CONSTRUCTION RECORD DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. STANTEC HAS NOT VERIFIED THE ACCURACY AND/OR COMPLETENESS OF INFORMATION AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE INCORPORATED HEREIN AS A RESULT. RENTON AIRPORT LIFT STATION REPLACEMENT LIFT STATION MISC. DETAILS DATE: 4/5/13 FIELDBOOK: PAGE: DRAWING N0: C9 SHEET: OF: 9 21 D r'1 � U^JJ Z C m0 m Cn - rnrn �z m z m � m 0 D A Z m m Cn D 0 0 0 o � c co co