Loading...
HomeMy WebLinkAboutWWP2703626.13LIGHTING FIXTURE SCHEDULE MANUFACTURER * LAMP TYPE DESCRIPTION NAME CATALOG NO. QTY.CATALOG NO. Al FLUORESCENT, LIGHT FIXTURE, 120 VAC, 4'-2" LONG, HIGH -IMPACT ACRYLIC LENS, MOLDED 32WT6 FIBERGLASS REINFORCED POLYESTER HOUSING, (2)-32W LAMPS, ENERGY SAVING BALLAST, LITHONIA DM 2 32 ARDP 120 2 32 WATT MOUNT TO CEILING U.L. LISTED FOR DAMP LOCATIONS A2 FLUORESCENT OUTDOOR AREA LIGHT - (2)-42W FLUORESCENT LAMPS, 120 VAC BALLAST, 9"H, 42 TRT 13"W, 7 3/8"D, DIE-CAST ALUMINUM HOUSING. MOUNT TOP OF FIXTURE Y ABOVE FINISHED GRADE, LITHONIA TWR1 2/42TRT MVOLT PE LPI 2 42 WATT PHOTOCELL INCLUDED, U.L. LISTED FOR WET LOCATIONS. A3 HIGH PRESSURE SODIUM OUTDOOR AREA LIGHT, 120 VAC, (1) -10OW HPS LAMP, SEE MOUNTING I HPS DETAILS ON DWG NO. E07. U.L. LISTED FOR WET LOCATIONS. LITHONIA TFL 100S RA2120 SCWA FCRA 1 LPI 100 WATT * NUMBER OF LAMPS PER FIXTURE ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE ITEM DESCRIPTION MANUFACTURER MODEL NO. ® SERVICE ENTRANCE DISCONNECT SWITCH - NEMA 4, HEAVY ► HDL 26100C WITH DUTY SERVICE RATED, 100% RATED CIRCUIT BREAKER, SQUARE D ENCLOSURE OR EQUAL 100-AMP, 600VOLT, 18,000 AMP INTERRUPTING RATING. © AUTOMATIC TRANSFER SWITCH - NEMA 1, 600V, 100-AMP. SEE SPECIFICATIONS SEE SPECIFICATIONS MOUNT TOP OF PANEL F - 0" FROM FINISHED GRADE. © GENERATOR RECEPTACLE -100A, 480 VOLT. 4-POLE, 3-WIRE, APPLETON DEL ADR1034 W THREADED CAP. WEATHER PROOF. MODEL AJA100 ANGEL ADAPTER OR EQUAL MANUAL TRANSFER SWITCH - NEMA 1, DOUBLE THROW, MODEL DTU363 OR NON -FUSED SAFETY SWITCH, 600V, 100-AMP. SQUARED EQUAL EO FLOAT SWITCH - SEE DETAIL ON DWG NO. E07 SEE SPECIFICATIONS SEE SPECIFICATIONS C LEVEL TRANSMITTER SEE SPECIFICATIONS SEE SPECIFICATIONS O CHECK VALVE LIMIT SWITCHES - CONTRACTOR SHALL SELECT SQUARE D HEAVY DUTY TYPE C, ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING CLASS 9007 OR EQUAL CONFIGURATION. SEE DETAIL ON DWG NO. E07. TRANSIENT VOLTAGE SURGE SUPPRESSOR, "SPD" SEE SPECIFICATIONS SEE SPECIFICATIONS VAULT FLOOD SWITCH - N.O. REED TYPE FLOAT SWITCH, 20 OMEGA MODEL LVN-20 OR VA. SEE DWG NO. E07 FOR DETAIL. EQUAL © COOLING THERMOSTAT - SPDT, 5°F DIFFERENTIAL. RANGE T631C1103 OR -300-1000F, SET AT 75°F. MOUNT 4'-0" ABOVE FINISHED FLOOR HONEYWELL EQUAL O INTRUSION ALARM SWITCH - CONTRACTOR SHALL SELECT HEAVY DUTY TYPE C, ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING SQUARE D CLASS 9007 OR CONFIGURATION. WIRE SWITCHES IN SERIES. EQUAL NU ELECTRICAL SPACE HEATER - 240 VAC, 1�, 3KW, WITH 24 MUH03-21 OR VOLT CONTROL TRANSFORMER. MOUNT BOTTOM OF QMARK EQUAL HEATER 6'- 6" ABOVE FINISHED FLOOR. © HEATING THERMOSTAT - DPST, 30F DIFFERENTIAL, RANGE T498B1512 OR 400-800F, SET AT 60"F. MOUNT 4'-0" ABOVE FINISHED FLOOR HONEYWELL EQUAL KEYSWITCH - WEATHERPROOF ENCLOSURE, MOUNT 4' ABOVE 1W7-B2-626 FINISHED GRADE. CONTRACTOR SHALL COORDINATE WITH BEST NO SUBSTITUTE BEST ACCESS COMPANY (KENT. WA) TO PROVIDE CORE TO MEET CITY OF RENTON STANDARDS. TO FLOWMETER - WITH REMOTE TRANSMITTER SEE SPECIFICATIONS SEE SPECIFICATIONS 1 P2 OUTSIDE 2 - - GROUNDING PER PAD -MOUNT TRANSFORMER DETAIL THIS BY UTILITY SHEET. i G N U TI 1( R UNDERGROUND PRIMARY - - SERVICE PER SERVING UTILITY REQUIREMENTS. 0 i UTILITY POWER P1 - 12470 - 480/277 - VOLT. 30 I CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS P1 UTILITY TRANSFORMER SERVICE ENTRANCE DISCONNECT 1 1/2" (3) - #3, (1) - #3 N P2 MAIN DISCONNECT UTILITY METER 1 1/2" (3) - #3, (1) - #3 N, (1) - #8 GRD P3 UTILITY METER AUTOMATIC TRANSFER SWITCH, "ATS" 1 1/2" (3) - #3, (1) - #3 N, (1) - #8 GRD P4 ENGINE GENERATOR SET MANUAL TRANSFER SWITCH, "MTS" 1 1/2" (3) - #3, (1) - #3 N, (1) - #8 GRD P5 GENERATOR RECEPTACLE MANUAL TRANSFER SWITCH, "MTS" 1 1/2" (3) - #3, (1) - #3 N, (1) - #8 GRID P6 MANUAL TRANSFER SWITCH, "MTS" AUTOMATIC TRANSFER SWITCH, "ATS" 1 1/2" (3) - #3, (1) - #3 N, (1) - #8 GRD P7 AUTOMATIC TRANSFER SWITCH, "ATS" MOTOR CONTROL CENTER, "MCC" 1 1/2" (3) - #3, (1) - #3 N, (1) - #8 GRD P8 MOTOR CONTROL CENTER, "MCC" MOTOR SPLICE HANDHOLE 1" (3) - #10, (1) - #10 GRD, MOTOR SENSOR CABLE P9 MOTOR CONTROL CENTER, "MCC" MOTOR SPLICE HANDHOLE 1" (3) - #10, (1) - #10 GRD, MOTOR SENSOR CABLE P,0 MOTOR SPLICE HANDHOLE PUMP NO. 1, P-1 2" PUMP MOTOR CABLES P11 MOTOR SPLICE HANDHOLE PUMP NO. 2, P-2 2" PUMP MOTOR CABLES P12 TELEMETRY PANEL, "RTU" LIGHTING PANEL, "L" 3/4" (2) - #12, (1) - #12 GRD P13 NOT USED THIS PLAN P14 LIGHTING PANEL, "L" ENGINE GENERATOR BLOCK HEATER 3/4" (2) - #12, (1) - #12 GRD P15 LIGHTING PANEL, "L" DEDICATED SUMP PUMP RECEPTACLE 3/4" (2) - #12, (1) - #12 GRD P16 LIGHTING PANEL, "L" OUTDOOR RECEPTACLE 3/4" (2) - #12, (1) - #12 GRD P17 LIGHTING PANEL, "L" SITE LIGHT 3/4" (2) - #10, (1) - #10 GRD I P18 LIGHTING PANEL, "L" ENGINE GENERATOR BATTERY CHARGER 3/4" (2) - #12, (1) - #12 GRD P19 LIGHTING PANEL, "L" BUILDING HEATER 3/4" (2) - #10, (1) - #10 GRD C1 WETWELL FLOATS FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE 2" MANUFACTURER FLOAT CABLES C2 VALVE LIMIT SWITCHES VALVE VAULT JUNCTION BOX 3/4" (2) - #14, (1) - #14 GRD C3 VALVE VAULT FLOOD SWITCH VALVE VAULT JUNCTION BOX 3/4" (2) - #14, (1) - #14 GRD C4 FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE TELEMETRY PANEL, "RTU" 1" (6) - #14, (1) - #14 GRD 7 BUILDING INTRUSION ALARM SWITCH TELEMETRY PANEL, "RTU" 3/4" (2) - #14, (1) - #14 GRD C6 NOT USED THIS PLAN C7 AUTOMATIC TRANSFER SWITCH, "ATS" ENGINE GENERATOR SET 3/4" (2) - #14, (1) - #14 GRD C8 TELEMETRY PANEL, "RTU" ENGINE GENERATOR SET 3/4" (10) - #14, (1) - #14 GRD C9 VALVE VAULT JUNCTION BOX TELEMETRY PANEL, "RTU" 3/4" (8) - #14, (1) - #14 GRD C10 TELEMETRY PANEL, "RTU" MOTOR CONTROL CENTER, "MCC" 1 1/4" (30) - #14, (1) - #14 GRD C,1 INTRUSION DISABLE SWITCH TELEMETRY PANEL, "RTU" 3/4" (2) - #14, (1) - #14 GRD C12 VALVE VAULT INTRUSION SWITCH VALVE VAULT JUNCTION BOX 3/4" (2) - #14, (1) - #14 GRD C13 BUILDING DOOR INTRUSION SWITCH TELEMETRY PANEL, "RTU" 3/4" (2) - #14, (1) - #14 GRD J1 TELEMETRY PANEL, "RTU" FLOW METER 1 1/2" MANUFACTURER'S CABLES J2 TELEMETRY PANEL, "RTU" ANTENNA NEW ON LIGHT POLE 1" ANTENNA CABLE J3 WETWELL LEVEL TRANSMITTER FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE in MANUFACTURER'S LEVEL TRANSMITTER CABLE J4 FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE TELEMETRY PANEL, "RTU" in MANUFACTURER'S LEVEL TRANSMITTER CABLE mml ATS MOTOR CONTROL CENTER, 480V, 30, 4W, 600A BUS, 42 KAIC WITHSTAND. I 1 UU/3 / TM 100% RATED 50KW I GROUND PER N.E.C. ELECTRICAL NOTES 1. MAIN REVENUE METERING. METER BASE AND ENCLOSURE BY CONTRACTOR PER SERVING UTILITY REQUIREMENTS. METER BY PUGET SOUND ENERGY. 2� 2. SERVICE ENTRANCE DISCONNECT SWITCH. 3 3. SEE DWG NO. E04 FOR CONTROL LOGIC DIAGRAMS. 4� 4. (2) - 5/8" X 8' COPPER GROUND RODS SPACED APART AS SHOWN ON DWG NO. E06. 5. WATERPROOF SPLICE. SEE DETAIL ON DWG NO. E06 (TYPICAL). 1 Iu I ) 30/3 NEUTRAL TM I I 0 SPD I � 0 I I I GND BUS PMR PHASE MONITOR RELAY I I I I INSIDE --__jw_ 100A, 480V, 3�, 3W PORTABLE GENERATOR RECEPTACLE ONE -LINE DIAGRAM NO SCALE SERVICE ENTRANCE DISCONNECT SWITCH SIN #6 MIN. GND BUS 25/2 POWER / TM MONITORING 480V 10KVA, 10, 3W 240/120V f__j)50/2 TM "L," 240/120V 9 WET WELL #6 #6 BOND TO PIPE IN VALVE CONCRETE VAULT REBAR MAT LIFER CONNECTION GROUNDING NO SCALE PANEL SCHEDULE L NO. L LOCATION: MCC SERVING: PUMP STATION 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 240/120 VOLTS 3 WIRE CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION OUTDOOR RECEPTACLES 0.54 20 20 0.28 SITE LIGHT EXTERIOR BUILDING LIGHTING 1.20 f 20 20 0.28 VALVE VAULT SUMP PUMP RECEPTACLE INDOOR BUILDING LIGHTING 0.08 20 20 1.20 ENGINE GENERATOR BLOCK HEATER TELEMETRY PANEL 0.50 20 20 0.50 ENGINE GENERATOR BATTERY CHARGER BUILDING HEATER 3.75 30 20 0.50 EXHAUST FAN AND INTAKE LOUVER BUILDING HEATER 2P 30 20 0.54 INTERIOR RECEPTACLE SPARE - 20 20 - SPARE SPARE - 20 - - SPACE SPACE - - - - SPACE CONNECTION LOAD: 9.37 KVA 39.04 AMPS DEMAND: LIGHTING AND CONTROL LOAD DEMAND LOAD: 7.79 KVA 32.46 AMPS ) MCP I i MCP I AS A AS A ( MOTOR MOTOR STARTER STARTER I i P8 P9 HANDHOLE Ku R 6727 %13TSg��� OVAL SIGNED. 01118113 SIGNED. 01118113 SEAL -OFF, W Q TYPICAL Z W Q �j 10 P1, a PROVIDE PLASTIC BUSHING Q Ll,� W AT END OF CONDUIT, �`► Z TYPICAL. Z Z W0 ac ;: LL! U. Q Z O 0 7.5HP 7.5HP Vuft i U PUMP 1 PUMP 2 P-1 P-2 LI„ j Wff WELL VA1JLT GLA551 Q V DN/5/ON 1 ffi EA 0 W Z J W ENGINEERS PLANNERS SCIENTISmw RH2 ENGINEERING, INC. -ttp: / /`www.rh2.e(-,,rr ELLINGI.1AM 76,ua:.= EAST WENATCHEE sos.ss -iLHU 14 Columbia P, SILVERDALE 3e0.876. S=3626 13 �L, SCALE: SHOWN 0 1" 2" REVISED TO CONFORM TO CONSTRUCTION RECORDS RH2 I&INEERING INC. 17ATE REVISED PER CONSTRUCTION RECORDS NO, REVISION DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG PLOT: 1 DWG No. ENGINEER: CCA E02 REVIEWED: MLM DATE: Nov 11, 2014 �"E` CLIENT: REN 13 GAD MLM 07/29/14 Joe No.: 112-023 17-- BY REVIEW DATE FILENAME: LIND-D-E-ONELINE.DWG � G7 m c * 2 030 C I m - cpcl "z m z m CLO D m D Z 0 C 9 W m cn D T1 n 0 o M �° o D �c C �c Z