Loading...
HomeMy WebLinkAboutWWP2703627.14STAINLESS STEEL NIPPLE AS REQUIRED, TYP. OF 3 't" STAINLESS STEEL TEE - Y2" STAINLESS STEEL BALL VALVE. TYP. OF 2 PRESSURE GAUGE. SEE SPECIFICATIONS %" STAINLESS STEEL DIAPHRAGM SEAL /" STAINLESS STEEL 450 BEND. ORIENT SUCH THAT GAUGE FACE IS VISIBLE FROM ACCESS HATCH ABOVE. %" STAINLESS STEEL THREADED TAP PROPOSED FORCE —. MAIN PIPE PRESSURE GAUGE 01 NOT TO SCALE NOTE: * PIPE AND CONDUIT PENETRATIONS LESS THAN 4" SHALL BE GROUTED WATER TIGHT AT BOTH SIDES. * ALL PROPOSED CAST IN PLACE PENETRATIONS SHALL BE SEALED USING THE OMNI SLEEVE SIGMA FLANGE WITH THRUST RESTRAINT. * PRECAST OR CORED PIPE PENETRATIONS SHALL BE SEALED PER THE DETAILS BELOW. *GRAVITY SEWER CONNECTIONS SHALL USE KOR-N-SEAL BOOTS. SHACKLE ROD SCHEDULE SHACKLE ROD FITTING NUMBER SIZE 4" 2 3/4" 6" 2 3/4" 8" 2 3/4" HOLE IN CONCRETE WALL OVERSIZED TO FIT NPC WATERSTOP GROUTING RING AND PIPE PER MANUFACTURER'S RECOMMENDATIONS PROPOSED 4" AND LARGER PIPE 1" i 4 CLEVIS H 2f" 0 SLEEV ALUMINUM SLEEVE, 6" LEN WITH END CAP, WELDEC HATCH STIFFENER, PROVIDE NPC WATERSTOP GROUTING RING OR APPROVED EQUAL. SEAL FLUSH TO WALL FACE EACH SIDE WITH WATERTIGHT GROUT OR EQUIVALENT _PIPE PENETRATION B NOT TO SCALE M01 FITTING . NUT ASSEMBLY TIE BOLT TIE ROD TIE BOLTS SHALL BE INSTALLED PER MANUFACTURER'S WRITTEN RECOMMENDATIONS SHACKLE ROD NOT TO SCALE M01 2" 0 ALUMINUM PIP TY 1/2 ACC NOTES: 1. LADDERS SHALL BE ALUMINUM INSIDE OF VALVE VAULT AND MANHOLE. LADDERS SHALL BE FRP WITH STAINLESS STEEL HARDWARE INSIDE OF WETWELL. 2, LADDER MUST MEET CONSTRUCTION REQUIREMENTS OF ANSI A14.3 CONCRETE WALLIRISER f MIN. 1 1" DIA. RUNGS, EQUALLY I SPACED VERTICALLY @ 12" / O.C. PLAN NOTE: 1. LOCATE SLEEVES TO NOT INTERFERE WITH HATCH CLOSING. 2. SAFETY CHAIN SHALL COVER 2 SIDES OF HATCH OPENINGS. ESS HATCH FALL PROTECTION Vi TO SCALE HATCH CURB BAR 3", OPENING 2Y2" X/2" BRACKETS T&B, 8' O.C. MAX. VERTICAL SPACING \ PROVIDE ADDITIONAL \ DIAGONAL/BRACKETS AT TOP SST LADDER SAFETY POST, BILCO CONNECTION LADDER -UP OR EQUAL, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. iol STRINGERS, FB 2%"X%" LADDER RAILS, PUNCH TO RECEIVE RUNGS TYP--r—r TYP ACCESS HATCH LIMITS 3/16" 2 12 n TYP. CONCRETE ANCHORS, (TYP.) �L. - -r-- IN LIEU OF TOP DIAGONAL, EXTEND RAILS AND BEND 3" AT FLOOR. SECURE WITH Y8" CONCRETE ANCHORS VAULT ACCESS LADDER E NOT TO SCALE S03 PROFILE STANDON ADJUSTABLE PIPE SUPPORT 2"0 GALVANIZED AS REQUIRED STEEL PIPE (2) 518"0 SS DRILL AND EPDXY ANCHOR SYSTEM EQUAL TO HILTI "HIT C100" WITH SS NUT AND WASHER, EMBED 4" MINIMUM VALVE VAULT FLOOR. a VERTICAL PIPE SUPPORT NOT TO SCALE R �` 2" SQUARE 1° ENTIRE LENGTH —/ 4.25" DIA. 1/8" MIN. THICKNESS 1" DIA SOLID METAL STOCK, LENGTH AS '118" MIN. THICKNESS —, REQUIRED 3t" SET SCREW 2.25" INSIDE MEASUREMENT 2.25" DEPTH OPERATING NUT EXTENSION Moe OPERATION NUT EXTENSION PER DETAIL F THIS SHE M02 VALVE BOX, PER CITY OF RENTON STANDARD DETAIL INSTALL VALVE PLUMB AND VERTICAL. PRETEST CLUSTERS PRIOR TO INSTALLATION. ECCENTRIC PLUG VALVE (FLxFL), FOR GEAR ACTUATORS, CONTRACTOR SHALL ORIENT PLUG VALVE SO SEAT IS TOP OF VALVE AND PLUG ROTATES UP 90" TO OPEN, AND WHEN BACKFILL AROUND VALVE WITH COMPACTED CRUSHED ROCK CLOSED FLOW IS AGAINST FACE OF PLUG FLOW 1 FOR PVC. PROVIDE VAN -STONE STYLE /� PROVIDE 4" THICK CONCRETE FLANGE ADAPTER (FLxS). INSTALL PER / SUPPORT BLOCK UNDER VALVE, TYP MANUFACTURER'S RECOMMENDATION.--------------� S 3 ISOLATION VALVE cGo4 G NOT TO SCALE RECORD DRAWING REVISED TO CONFORM TO CONSTRIUICpqN RECORDS RH2 EN UNEERING INC. ATE on 0 w ti ocn N .� z 0 cn 0 0 J Ix Q 0 Io c z 0 O UJ U nof Z o W Z � Q W/� U cc O U- z 0 N CV W 0 0 +i Z Z W w t Q cr_ o 0 0 H 2 N ly{ o a Q � W W 2 w O � w � SCALE: SHOWN DRAWING IS FULL SCALE WHEN BAR MEASURES 2" DWG NO.: 02 1'14O M� 1721/1 z z = C m m z m 111 cn 0 D � D i T DO D co c n D m =:E c I7 -00 n- n � uz z m s D z^ c �T W m m c c ! N zz r 1 n� m m N z I cn D m 0 O �� m Imo D H C o0 _ cn m 7