HomeMy WebLinkAboutWWP2703627.14STAINLESS STEEL NIPPLE
AS REQUIRED, TYP. OF 3
't" STAINLESS STEEL TEE -
Y2" STAINLESS STEEL BALL
VALVE. TYP. OF 2
PRESSURE GAUGE. SEE
SPECIFICATIONS
%" STAINLESS STEEL DIAPHRAGM SEAL
/" STAINLESS STEEL 450 BEND. ORIENT SUCH THAT
GAUGE FACE IS VISIBLE FROM ACCESS HATCH ABOVE.
%" STAINLESS STEEL THREADED TAP
PROPOSED
FORCE —.
MAIN PIPE
PRESSURE GAUGE 01
NOT TO SCALE
NOTE:
* PIPE AND CONDUIT PENETRATIONS LESS THAN 4" SHALL BE GROUTED WATER TIGHT AT BOTH SIDES.
* ALL PROPOSED CAST IN PLACE PENETRATIONS SHALL BE SEALED USING THE OMNI SLEEVE SIGMA
FLANGE WITH THRUST RESTRAINT.
* PRECAST OR CORED PIPE PENETRATIONS SHALL BE SEALED PER THE DETAILS BELOW.
*GRAVITY SEWER CONNECTIONS SHALL USE KOR-N-SEAL BOOTS.
SHACKLE ROD
SCHEDULE
SHACKLE ROD
FITTING
NUMBER SIZE
4"
2 3/4"
6"
2 3/4"
8"
2 3/4"
HOLE IN CONCRETE WALL OVERSIZED TO FIT
NPC WATERSTOP GROUTING RING AND PIPE
PER MANUFACTURER'S RECOMMENDATIONS
PROPOSED 4" AND
LARGER PIPE
1" i
4
CLEVIS H
2f" 0 SLEEV
ALUMINUM SLEEVE, 6" LEN
WITH END CAP, WELDEC
HATCH STIFFENER,
PROVIDE NPC WATERSTOP GROUTING RING OR
APPROVED EQUAL. SEAL FLUSH TO WALL FACE EACH
SIDE WITH WATERTIGHT GROUT OR EQUIVALENT
_PIPE PENETRATION B
NOT TO SCALE M01
FITTING .
NUT ASSEMBLY
TIE BOLT
TIE ROD
TIE BOLTS SHALL BE INSTALLED
PER MANUFACTURER'S WRITTEN
RECOMMENDATIONS
SHACKLE ROD
NOT TO SCALE M01
2" 0 ALUMINUM PIP
TY
1/2
ACC
NOTES:
1. LADDERS SHALL BE ALUMINUM INSIDE OF VALVE
VAULT AND MANHOLE. LADDERS SHALL BE FRP
WITH STAINLESS STEEL HARDWARE INSIDE OF
WETWELL.
2, LADDER MUST MEET CONSTRUCTION
REQUIREMENTS OF ANSI A14.3
CONCRETE WALLIRISER
f
MIN.
1
1" DIA. RUNGS, EQUALLY I
SPACED VERTICALLY @ 12" /
O.C. PLAN
NOTE:
1. LOCATE SLEEVES TO NOT INTERFERE WITH HATCH CLOSING.
2. SAFETY CHAIN SHALL COVER 2 SIDES OF HATCH OPENINGS.
ESS HATCH FALL PROTECTION
Vi TO SCALE
HATCH CURB
BAR 3", OPENING
2Y2" X/2" BRACKETS T&B, 8'
O.C. MAX. VERTICAL
SPACING
\ PROVIDE ADDITIONAL
\ DIAGONAL/BRACKETS AT TOP
SST LADDER SAFETY POST, BILCO CONNECTION
LADDER -UP OR EQUAL, INSTALL
PER MANUFACTURER'S
RECOMMENDATIONS.
iol
STRINGERS, FB 2%"X%" LADDER RAILS,
PUNCH TO RECEIVE RUNGS
TYP--r—r
TYP
ACCESS HATCH LIMITS
3/16"
2
12 n
TYP.
CONCRETE ANCHORS,
(TYP.)
�L.
- -r-- IN LIEU OF TOP DIAGONAL,
EXTEND RAILS AND BEND 3" AT
FLOOR. SECURE WITH Y8"
CONCRETE ANCHORS
VAULT ACCESS LADDER E
NOT TO SCALE S03
PROFILE
STANDON ADJUSTABLE
PIPE SUPPORT
2"0 GALVANIZED
AS REQUIRED STEEL PIPE
(2) 518"0 SS DRILL AND EPDXY
ANCHOR SYSTEM EQUAL TO HILTI
"HIT C100" WITH SS NUT AND
WASHER, EMBED 4" MINIMUM
VALVE VAULT FLOOR.
a
VERTICAL PIPE SUPPORT
NOT TO SCALE
R
�` 2" SQUARE
1° ENTIRE LENGTH —/
4.25" DIA. 1/8" MIN. THICKNESS 1" DIA SOLID METAL
STOCK, LENGTH AS
'118" MIN. THICKNESS —, REQUIRED
3t" SET SCREW
2.25" INSIDE MEASUREMENT
2.25" DEPTH
OPERATING NUT EXTENSION Moe
OPERATION NUT EXTENSION PER
DETAIL F THIS SHE
M02
VALVE BOX, PER CITY OF RENTON
STANDARD DETAIL
INSTALL VALVE PLUMB AND VERTICAL.
PRETEST CLUSTERS PRIOR TO
INSTALLATION.
ECCENTRIC PLUG VALVE (FLxFL), FOR GEAR
ACTUATORS, CONTRACTOR SHALL ORIENT
PLUG VALVE SO SEAT IS TOP OF VALVE AND
PLUG ROTATES UP 90" TO OPEN, AND WHEN
BACKFILL AROUND VALVE WITH
COMPACTED CRUSHED ROCK
CLOSED FLOW IS AGAINST FACE OF PLUG FLOW
1
FOR PVC. PROVIDE VAN -STONE STYLE /� PROVIDE 4" THICK CONCRETE
FLANGE ADAPTER (FLxS). INSTALL PER / SUPPORT BLOCK UNDER VALVE, TYP
MANUFACTURER'S RECOMMENDATION.--------------�
S 3
ISOLATION VALVE cGo4 G
NOT TO SCALE
RECORD DRAWING
REVISED TO CONFORM
TO CONSTRIUICpqN RECORDS
RH2 EN UNEERING INC. ATE
on
0
w
ti
ocn
N
.�
z
0
cn
0
0
J
Ix
Q
0
Io
c
z
0
O
UJ
U
nof
Z
o
W
Z
�
Q
W/�
U
cc
O
U-
z
0
N
CV
W
0
0
+i
Z
Z
W
w
t
Q
cr_
o
0
0
H
2
N
ly{
o
a
Q
�
W
W
2
w
O
�
w
�
SCALE: SHOWN
DRAWING IS FULL SCALE WHEN
BAR MEASURES 2"
DWG NO.:
02 1'14O
M� 1721/1
z
z
=
C
m
m
z
m
111
cn
0
D
� D
i T
DO
D co
c n
D m
=:E
c I7 -00
n-
n �
uz
z
m
s
D
z^
c
�T
W
m
m
c
c
!
N
zz
r
1
n�
m
m
N
z
I cn
D
m
0
O
��
m
Imo
D
H C
o0
_ cn
m
7