Loading...
HomeMy WebLinkAboutWWP2703628.10MOTOR CONTROL CENTER, 48OV, 30, 4W, 600A BUS, 42 KAIC WITHSTAND. LIGHTING FIXTURE SCHEDULE MANUFACTURER * LAMP TYPE DESCRIPTION NAME CATALOG NO. QTY. CATALOG NO. REMARKS Al METAL HALIDE OUTDOOR AREA SECURITY LIGHT, 120 VAC, (1) METAL HALIDE - 10OW METAL HALIDE LAMP, MOUNT TOP OF FIXTURE 12" LITHONIA TDD 100ML 120 M2 1 100 WATT BELOW TOP OF POLE. U.L. LISTED FOR WET LOCATIONS. * NUMBER OF LAMPS PER FIXTURE ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE ITEM DESCRIPTION MANUFACTURER MODEL NO. A O SERVICE ENTRANCE DISCONNECT SWITCH - NEMA 3R, HEAVY DUTY SERVICE RATED, 100% RATED CIRCUIT BREAKER, 100-AMP, HDL 26100C WITH 600VOLT, 18,000 AMP INTERRUPTING RATING. SQUARE D ENCLOSURE OR EQUAL 4 MANUAL TRANSFER SWITCH - NEMA 3R, DOUBLE THROW, MODEL DTU363RB NON -FUSED SAFETY SWITCH, 60OV, 100-AMP. SQUARE D OR EQUAL 4 GENERATOR RECEPTACLE - 100A, 480 VOLT, 4-POLE, 3-WIRE, APPLETON MODEL ADR1034 W/ THREADED CAP, WEATHER PROOF. MODEL AJA100 ANGEL ADAPTER OR EQUAL 4D NOT USED THIS PLAN 0 FLOAT SWITCH - SEE DETAIL ON DWG NO. E07 SEE SEE SPECIFICATIONS SPECIFICATIONS FO LEVEL TRANSMITTER SEE SPECIFICATIONS SEE SPECIFICATIONS 4G CHECK VALVE LIMIT SWITCHES - CONTRACTOR SHALL SELECT HEAVY DUTY ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING SQUARE D TYPE C, CLASS CONFIGURATION. SEE DETAIL ON DWG NO. E07. 9007 OR EQUAL 0 NOT USED THIS PLAN KO VAULT FLOOD SWITCH - N.O. REED TYPE FLOAT SWITCH, 20 OMEGA MODEL LVN-20 OR EQUAL VA. SEE DWG NO. E07 FOR DETAIL. 4 NOT USED THIS PLAN O INTRUSION ALARM SWITCH - CONTRACTOR SHALL SELECT HEAVY DUTY ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING SQUARE D TYPE C, CLASS CONFIGURATION. WIRE SWITCHES IN SERIES. 9007 OR EQUAL PROPOSED PAD -MOUNT TRANSFORMER BY UTILITY PROPOSED UNDERGROUND PRIMARY SERVICE PER 4 SERVING UTILITY REQUIREMENTS. UTILITY POWER 12470 - 480/277 - VOLT. 30 POWER CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS P1 UTILITY TRANSFORMER SERVICE ENTRANCE DISCONNECT 1 1/4" (3) - #3, (1) - #3 N P2 MAIN DISCONNECT UTILITY METER 1 1/4" (3) - #3, (1) - #3 N, (1) - #8 GRID 43 UTILITY METER MANUAL TRANSFER SWITCH, "MTS" 1 1/4" (3) - #3, (1) - #3 N, (1) - #8 GRID 44 STANDBY GENERATOR RECEPTACLE MANUAL TRANSFER SWITCH, "MTS" 1 1/4" (3) - #3, (1) - #3 N, (1) - #8 GRD P5 BELOW "MTS" STUB & CAP (FUTURE EG SET) 1 1/4" NYLON PULL CORD P6 LIGHTING PANEL, "L" SITE LIGHT 3/4" (2) - #12, (1) - #12 GRD P7 MANUAL TRANSFER SWITCH, "MTS" MOTOR CONTROL CENTER, "MCC" 1 1/4" (3) - #3, (1) - #3 N, (1) - #8 GRID P8 MOTOR CONTROL CENTER, "MCC" MOTOR SPLICE HANDHOLE 1" (3) - #10, (1) - #10 GRD, MOTOR SENSOR CABLE _P� MOTOR CONTROL CENTER, "MCC" MOTOR SPLICE HANDHOLE 1" (3) - #10, (1) - #10 GRD, MOTOR SENSOR CABLE P DO MOTOR SPLICE HANDHOLE PUMP NO. 1, P-1 2" PUMP MOTOR CABLES CP11 MOTOR SPLICE HANDHOLE PUMP NO. 2, P-2 2" PUMP MOTOR CABLES P4 TELEMETRY PANEL, "RTU" LIGHTING PANEL, "L" 3/4" (2) - #12, (1) - #12 GRID P1 j LIGHTING PANEL, "L" STUB & CAP 3/4" 3/8" NYLON PULL CORD P:p14 LIGHTING PANEL, "L" STUB & CAP 3/4" 3/8" NYLON PULL CORD P�.P15 LIGHTING PANEL, "L" DEDICATED SUMP PUMP RECEPTACLE 3/4" (2) - #12, (1) - #12 GRD P��4 LIGHTING PANEL, "L" OUTDOOR RECEPTACLE 3/4" (2) - #12, (1) - #12 GRD CON OL CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS U WETWELL FLOATS FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE 2" MANUFACTURER FLOAT CABLES C2 VALVE LIMIT SWITCHES VALVE VAULT JUNCTION BOX 3/4" (2) - #14, (1) - #14 GRD C3 VALVE VAULT FLOOD SWITCH VALVE VAULT JUNCTION BOX 3/4" (2) - #14, (1) - #14 GRD C4 FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE TELEMETRY PANEL, "RTU" 1" (6) - #14, (1) - #14 GRD Q'�5 BUILDING INTRUSION ALARM SWITCH TELEMETRY PANEL, "RTU" 3/4" (2) - #14, (1) - #14 GRD (: D6 OVERFLOW LEVEL FLOAT FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE 1" MANUFACTURER'S FLOAT CABLES C7 F BELOW "MTS" STUB & CAP (FUTURE EG SET) 3/4" 3/8" NYLON PULL CORD C8 TELEMETRY PANEL, "RTU" STUB & CAP (FUTURE EG SET) 3/4" 3/8" NYLON PULL CORD C9 VALVE VAULT JUNCTION BOX TELEMETRY PANEL, "RTU" 3/4" (8) - #14, (1) - #14 GRD C1O TELEMETRY PANEL, "RTU" MOTOR CONTROL CENTER, "MCC" 1 1/4" (30) - #14, (1) - #14 GRID 411/ INTRUSION DISABLE SWITCH TELEMETRY PANEL, "RTU" 3/4" (2) - #14, (1) - #14 GRD C12 VALVE VAULT INTRUSION SWITCH VALVE VAULT JUNCTION BOX 3/4" (2) - #14, (1) - #14 GRD C`4 "MCC" DOOR INTRUSION SWITCH TELEMETRY PANEL, "RTU" 3/4" (2) - #14, (1) - #14 GRD INSTRUMENTATION CONDUIT AND CONDUCTOR SCHEDULE CIRCUIT SOURCE DESTINATION TRADE SIZE (QUANTITY) CONDUCTORS J 4 TELEMETRY PANEL, "RTU" STUB & CAP (FUTURE FLOW METER) 1 1/2" 3/8" NYLON PULL CORD J2 TELEMETRY PANEL, "RTU" ANTENNA 2" ANTENNA CABLE J3 I WETWELL LEVEL TRANSMITTER FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE 3/4" MANUFACTURER'S LEVEL TRANSMITTER CABLE J4 FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE TELEMETRY PANEL, "RTU" 3/4" (1) 2-CONDUCTOR SHIELDED CABLE P3 0/3 I I 0% IT" MTS 3 u I CP 7 ONE -LINE DIAGRAM NO SCALE ELECTRICAL NOTES 1� 1. PROPOSED MAIN REVENUE METERING. METER BASE AND ENCLOSURE BY CONTRACTOR PER SERVING UTILITY REQUIREMENTS. METER BY PUGET SOUND ENERGY. 2. PROPOSED SERVICE ENTRANCE DISCONNECT SWITCH. 3. PROPOSED MANUAL TRANSFER SWITCH. LEAVE ADEQUATE ROOM FOR THE INSTALLATION OF A AUTOMATIC TRANSFER SWITCH THAT WILL REPLACE THE MTS IN THE FUTURE. THE FUTURE ATS ENCLOSURE DIMENSIONS ARE 40"H X 30"W. 4� 4. PROPOSED MOTOR CONTROL CENTER. NEMA 3R OUTER ENCLOSURE WITH NEMA 1 INNER ENCLOSURES FOR EQUIPMENT. 5. WATERPROOF SPLICE. SEE DETAIL ON DWG NO. E06 (TYPICAL). 6 6. (2) - 5/8" X 8' COPPER GROUND RODS SPACED APART AS SHOWN ON DWG NO. E04. 4� 7. SEE DWG NO. E08 FOR CONTROL LOGIC DIAGRAMS. 8�RENTON 8. PROPOSED GENERATOR RECEPTACLE. COORDINATE WITH CITY OF UTILITIES FOR CORRECT PHASING OF GENERATOR RECEPTACLE CONNECTIONS. I ✓ NEUTRALI I I GND BUS SERVICE ENTRANCE DISCONNECT SWITCH S/N #6 MIN. 130/3 // TM 0 SPD 0 GND BUS POWER MONITORING PMR PHASE MONITOR RELAY #6 BOND TO PIPE IN VALVE VAULT GROUNDING NO SCALE / 15/2 T1A ww O PROPOSED WET WE #6 CONCRETE REBAR MAT 4 UFER CONNECTION PANEL SCHEDULE L Al NO. L LOCATION: SERVING: MCC PUMP STATION 1 3 5 7 9 11 13 15 17 2 4 6 8 10 12 14 16 18 240/120 VOLTS 3 WIRE CIRCUIT DESCRIPTION KVA AMP AMP KVA CIRCUIT DESCRIPTION OUTDOOR RECEPTACLES 0.54 20 20 0.28 POLE LIGHTING VALVE VAULT SUMP PUMP RECEPTACLE 1.20 20 20 - SPARE SHELTER LIGHTS 0.08 20 20 - SPARE TELEMETRY PANEL 0.50 20 20 - SPARE SPARE - 20 20 - SPARE SPARE - 20 - - SPACE SPARE - 20 - - SPACE SPACE - - MANSPACE - - 2P - CONNECTION LOAD: 2.60 KVA 10.83 AMPS DEMAND: LIGHTING AND CONTROL LOAD DEMAND LOAD: 2.06 KVA 8.58 AMPS 1MCP MCP OSED A IHOLE E06 PROPOSED SEAL -OFF, TYPICAL 'LASTIC BUSHING AT :ONDUIT, TYPICAL. G �� i4 16727 CISTV,V' 1 `SIONAL SIGNED. 05123112 K MILL �F WASfj` O 38613 `�:eCISTEg>V ti ONAL SIGNED. 05123112 \N'r% Z Zo O Q �Wr � CC U. wAft 0 ".j CC Uj m 0 Z Q Q 0 Q 0 cn W W z� J 0 W W = Z V 0cn J Q V CC F_ U W W ENGINEERS PLANNERS RH2 ENGINEERING, INC. http://www.rh2.com mailbox&h2.com 1.800.720.8052 BELLINGHAM 36o.676.u.. 454 West Horton Road BOTHELL 425.951.L 22722 29th Drive SE, Suite 210 EAST WENATCHEE S09.886.29oc. 300 Simon Street, Suite 5 RICHLAND S09.946.S 181 114 Columbia Point Drive, Suite C SILVERDALE 36o.876.7960 2021 NW Mhyre Rd, Suite 107 TACOMA 2S3.272.3OS9 621 Pacific Avenue Suite 104 SCALE: SHOWN 0 1" 2" DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG RECORD DRAWING PLOT: 1 DWG NO. REVISED TO CONFORM ENGINEER: CCA E03 S=3628 10 TO CON TRUCTIOP RECORDS REVIEWED: MLM d,4� 04/25/12 DATE: Jul 15, 2013 sNEE.°. RH2 RING INC. DATE CLIENT: REN O REVISED TO CONFORM TO CONSTRUCTION RECORDS AHF EH 04/25/13 JOB NO.: 112-033 17 N0. REVISION BY REVIEW DATE FILENAME: LIBHS-D-EO2.DWG r to r �o z N o N