HomeMy WebLinkAboutWWP2703628.8WAg� `oy 16727 019TSit ONAL ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURES/DEVICES ABBREVIATIONS LADDER LOGIC SYMBOL LEGEND — CIRCUIT BREAKER SERVICE ENTRANCE, SWITCHGEAR, SPDT — SINGLE POLE, DOUBLE THROW INDICATOR LIGHT INDICATOR LIGHT RELAY SIGNED: 05123112 MjLL XXX/YY — CB SIZE & N0. OF POLES ET —ELECTRONIC TRIP MOTOR CONTROL CENTER, OR PANELBOARD FLUORESCENT FIXTURE O SPST — SINGLE POLE, SINGLE THROW DPST — DOUBLE POLE, SINGLE THROW RELAY A — AMBER G — GREEN XYZ TR —Timed relay TM — THERMAL MAGNETIC BREAKER WP — WEATHER—PROOF B — BLUE R — RED 123 CR — Control relay of WAS�r MCP — MOTOR CIRCUIT PROTECTOR SE — SERVICE ENTRANCE H: 0WALL/CEILING MOUNTED FIXTURE GFI — GROUND FAULT INTERRUPT P - POWER C — CLEAR W — WHITE 0 SURFACE MOUNTED PANELBOARD C —CONTROL GFI —GROUND FAULT INTERRUPTER J — INSTRUMENTATION FLOAT SWITCH FUSE PC — POWER & CONTROL CJ — CONTROL & INSTRUMENTATION LIMIT SWITCH LIMIT SWITCH, NORMALLY OPEN O FLOAT SWITCH, NORMALLY OPEN �38613 0 SlorSTWV& FUSED DISCONNECT SWITCH PLUG—IN CONNECTION FLUSHED MOUNTED PANELBOARD EMERGENCY LIGHT WITH SELF � CONTAINED BATTERY CKT. — CIRCUIT C.O. —CONDUIT ONLY N.L. —NIGHT LIGHT RTM RUN TIME METER AL. — ALUMINUM LIMIT SWITCH FLOAT SWITCH SIGNED: 05123112 V NXX FIELD CONTROL STATION WITH NEMA � REQUIREMENTS. SURFACE OR PENDANT MOUNTED O FIXTURE CU. — COPPER LIMIT SWITCH, NORMALLY CLOSED FLOAT SWITCH, NORMALLY CLOSED LKI MOTOR OPERATION COUNTER N1 —NEMA 1 SSRVS NNEMA 3R RECESSED FIXTURE O HOA HAND —OFF —AUTO SWITCH ETM RUN TIME METER N4 — NEMA 4 OC OPERATION COUNTER TIME DELAY CONTACT PUSHBUTTON V SSRVS —SOLID STATE N4SS —NEMA 4 STAINLESS STEEL N4F — NEMA 4 FIBERGLASS MD MOTION DETECTOR MRIL MOTOR RUN INDICATION LIGHT --� �� TIME DELAY CONTACT, NORMALLY OPEN TIME TO CLOSE 1 I --- '� PUSHBUTTON, NORMALLY CLOSED REDUCED VOLTAGE STARTER N6 —NEMA 6 SFIL SEAL FAIL INDICATION LIGHT � ` ML N12 — NEMA 12 GASKETED PC PHOTO CONTROL CELL SFTR SEAL FAIL TRIP RESET OTIL OVER TEMPERATURE INDICATION LIGHT MOIL MOTOR OVERLOAD INDICATION LIGHT TIME DELAY CONTACT TIME DELAY CONTACT, NORMALLY PUSHBUTTON � L_ PUSHBUTTON, NORMALLY OPEN � VARIABLE FREQUENCY DRIVE � EQUIPMENT MOUNTING STAND SWITCH OUTLETS CLOSED, TIME TO OPEN O 0 IV rV S ® STANDARD SWITCH, 120VAC, 20 AMP INDICATE TYPE BY MOTOR STARTER T LETTER INSTRUMENT METER THERMOSTAT HEATER, WATTAGE NOTED S ® 3—WAY SWITCH, 120VAC, 20 AMP TIME DELAY CONTACT A B MOTOR STARTER W/ OPERATOR 3 3WAY — — A AMMETER VAR VARMETER AH — AMPERE —HOUR VARH — VARHOUR METER TIME DELAY CONTACT, NORMALLY OPEN, TIME TO OPEN ;;�--_�„� __. THERMO SWITCH, NORMALLY OPEN DEVICES C D A — HAND —OFF —AUTO EQUIPMENT CONNECTION 3—POSITION SWITCH, 120VAC, 20 AMP, S ® LABEL SWITCH POSITION PF — POWER FACTOR W — WATTMETER V B — OPERATIONAL COUNTER HOA HOA HAND —OFF —MOTION OR PHOTO AM — VOLTMETER WH — WATTHOUR METER TIME DELAY CONTACT THERMOSTAT C — RUN TIME METER D —RUN LIGHT M SINGLE PHASE MOTOR. HORSEPOWER AS NOTED VA — VOLT AMMETER �—�—� TIME CLOSED, DLAY TMEOTO CLOSE -- THERMO SWITCH, NORMALLY CLOSED THERMO E — FAIL LIGHT RACEWAY LEGEND I DEE SINGLE —POLE F PILOT —LIGHTED � O F —EMERGENCY STOP KIRK KEY INTERLOCK THREE PHASE MOTOR. S DOUBLE —POLE S KEY —OPERATED 51T ��N L6N� P PROPOSED POWER RELAY CONTACT, NC FLOWSWITCH 0 Z 1Q0 HORSEPOWER AS NOTED 2 3 THREE WAY K S LOW VOLTAGE � RELAY CONTACT, INSTANTANEOUS CHANGE {�.__� C FLOWSWITCH, NORMALLY OPEN � O W POWER TRANSFORMER V TEL PROPOSED TELEPHONE RELAY CONTACT, NO 1 O CONTROL POWER TRANSFORMER HP SINGLE PHASE MOTOR. HORSEPOWER AS NOTED S FOUR WAY 4 S MASTER M TELM PROPOSED INSTRUMENTATION ~ QLU S DIMMER ❑ PUSHBUTTON PRESSURE SWITCH 0 J TRANSFORMER ELECTRICAL PLUG D Fo PROPOSED FIBER OPTICS DUU)ING 0P F/JC/LITY PL.tIN LEC,ffNP 0FIRE PRESSURE SWITCH, NORMALLY OPEN FLOWSWITCH FLOWSWITCH, NORMALLY CLOSED � Cr L&. ,J Q SYSTEM SYMBOLS < HEAT DETECTOR U4 CURRENT TRANSFORMER Eh DISCONNECT SWITCH EXPOSED RACEWAY OPRESSURE V OS SMOKE DETECTOR _ _ _ _ _ CONCEALED, UNDERGROUND, EMBEDDED, OR SWITCH VOLTAGE TRANSFORMER ECONCRETE i FUSED DISCONNECT SWITCH D FIRE ALARM DISPATCH STROBE ALARM ENCASED RACEWAY PRESSURE SWITCH, NORMALLY CLOSED 2 POLE SWITCH HOME RUN TO PANELBOARD OR AS INDICATED I "'terUj CONTACTOR COMBINATION MOTOR STARTER ❑A FIRE ALARM AUDIBLE/VISUAL ALARM M W AND DISCONNECT SWITCH � CONDUIT RUN, BROKEN AND CONTINUED SAME "► J F❑ FIRE ALARM MANUAL PULL STATION SHEET OR AS NOTED W T CAPACITOR FLEXIBLE CONDUIT RECEPTACLES AND JUNCTION BOX SYMBOLS ADDITIONAL SYMBOLS OJ CEILING JUNCTION BOX O SOUND SYSTEM SPEAKER ENGINE GENERATOR CONDUIT RUN. HATCH MARKS INDICATE NUMBER OF CONDUCTORS Q—}—---� 3 POLE SWITCH GENERATOR CONNECTION --�J WALL JUNCTION BOX V SOUND SYSTEM VOLUME CONTROL CALLOUT INDICATING CONDUIT SIZE, NUMBER AND SIZE OF WIRE. RECEPTACLE Y" GRC, 2—#12 S FLOOR JUNCTION BOX DOORBELL N SOLID NEUTRAL � DUPLEX WALL RECEPTACLE 120V CALLOUT INDICATING CONDUIT PER SCHEDULE VALVE SYMBOLS TB TERMINAL BLOCK WP = WEATHERPROOF G = GROUNDED XXX IG = ISOLATED GROUND PILOT VALVE SOLENOID _6� CONDUIT BENT UP OR TOWARD . GF = GROUND FAULT INTERRUPTER SURGE PROTECTION DEVICE DOUBLE DUPLEX CONDUIT BENT DOWN OR AWAY I VALVE GENERAL NOTES ENGINEER S SPD SURGE PROTECTION DEVICE SINGLE RECEPTACLE, 120V CAPPED CONDUIT PLANNER = SCIENTISTS ° - (ALTERNATIVE) 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL SINGLE RECEPTACLE, 208V CHECK VALVE ELECTRICAL & SIGNAL PLAN DEVICES APPEAR IN THIS SET OF PLANS, RH2 ENGINEERING, INC. S GROUNDING SYSTEM SYMBOLS DUPLEX FLOOR RECEPTACLE, 120V SV ZS SOLENOID VALVE COIL INTRUSION SWITCH 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL EQUIPMENT http://www.rh2.com ® SHALL BE DETERMINED IN THE FIELD BY THE SHOWN ON THESE DRAWINGS OR DESCRIBED CONTRACTOR. THE IN THE SPECIFICATIONS INSTALLATION OF ALL EQUIPMENT SHALL CONFORM TO THE mailbox0rh2.com 1.800.720.8052 GROUND SPECIAL PURPOSE WALL RECEPTACLE, *<1 MV MOTORIZED VALVE COIL MD MOTION DETECTOR REQUIREMENTS SET FORTH IN THE LATEST EDITIONS OF ALL APPLICABLE CODES AND UTILITY BELLINGHAM 360.676.083, 454 West Horton Road METAL PIPE GROUND FV� I_D O RATING AS NOTED CLOCK CONTROL VALVE � � � M 1 MOTOR LT LEVEL TRANSDUCER COMPANY STANDARDS. CONTACT THE UTILITY REQUIREMENTS. COMPANY REPRESENTATIVES AND VERIFY THEIR BOTHELL n2s.ssl.�oo 22722 29th Drive SE, Suite 210 ELECTRICAL SITE PLAN SYMBOLS CONNECTION POINT, EXOTHERMIC WELD. CADWELD OR APPROVED EQUAL. FS FLOOD SWITCH HE HEATING ELEMENT O O 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER EAST 509.886.29f3( 300 Simon 300 Simon Street, Suite 5 TV ❑ TELEVISION UTILITY POLE AND GUY WIRE � REASON. NO PAYMENT WILL BE MADE FOR CHANGES WHICH HAVE NOT BEEN FAVORABLY O GROUND ROD SIZED PER N.E.C. USE EXOTHERMIC WELD CONNECTION AT , TELEPHONE HH MANHOLE OR HANDHOLE 9PS LIMIT SWITCH PRESSURE SWITCH REVIEWED BY THE ENGINEER. RICHLAND so9.946.51i: 114 Columbia Point Drive, Suite C SILVERDALE THE GROUND ROD. TELEPHONE/DATA WITH CABLE HH BURIED POWER PB PANIC BUTTON PE PRESSURE ELEMENT 360.876.7960 2021 NW Mhyre Rd, Suite 107 PIGTAIL, BARE COPPER, LENGTH AS �P VAULT OR MANHOLE TACOMA 2s3.272.30W 621 Pacific Avenue Suite 104 � REQUIRED, 8' MINIMUM. CONNECTION POINT, MECHANICAL, TELEPHONE VAULT OR PEDESTAL t T J THERMOSTAT SWITCH FE FLOW ELEMENT �.� 362808 SCALE: SHOWN COMPRESSION TYPE. FIBER OPTICS VAULT OR PEDESTAL KEY ZS INTRUSION SWITCH — KEY AE ANALYSIS ELEMENTHKN!�i � „ 0 1 2 0-0 LUMINAIRE DRAWING IS NOT TO SCALE IF BAR IS NOT 2" LONG RECORD DRAWING PLOT: 1 DWG No. PAD —MOUNT TRANSFORMER REVISED TO CONFORM TO CON TRUCTIO RECORDS ENGINEER: CCA E01 REVIEWED: MLM ROAD DATE: JUI 15, 2013 SHEET NO. 04/25/12 RH2 RING INC. DATE 8 CLIENT: REN ?\ REVISED TO CONFORM TO CONSTRUCTION RECORDS AHF EH 04/25/13 1/7 JOB NO.: 112-033 FILENAME: LIBHS—D—EOI.DWG NO. REVISION BY REVIEW DATE O z lop 4w t 0