Loading...
HomeMy WebLinkAboutWWP2703628.9APPROXIMATE LOCATION OF GAS MAIN, INSTALLED BY OTHERS PROPOSED ELECTRICAL SYSTEM P1 ® o o— don ..0000000, jAd -'114 1 i I L u F71 M► x 4` PROPOSED LIFT STATION SITE, SEE DWG NO. E04 FOR MORE INFORMATION. ELECTRICAL DOTES L, aon don don don dW din, INSTALL BOLLARDS AROUND TRANSFORMER AS NECESSARY PER PSE STANDARDS AND REQUIREMENTS FOR PROTECTION OF PAD —MOUNT TRANSFORMER. 1. EXISTING UTILITY POLE. PUGET SOUND ENERGY SHALL PROVIDE PRIMARY SERVICE CONNECTION AT TOP OF POLE. 2� 2. PROPOSED PRIMARY UNDERGROUND POWER SERVICE. CONTRACTOR SHALL PROVIDE TRENCHING, BACKFILL AND RESTORATION PER PUGET SOUND ENERGY REQUIREMENTS. PUGET SOUND ENERGY SHALL PROVIDE AND INSTALL CONDUIT. PUGET SOUND ENERGY SHALL PROVIDE AND INSTALL PRIMARY POWER SERVICE CONDUCTORS. 3�3. PROPOSED PAD —MOUNT TRANSFORMER. CONTRACTOR SHALL PROVIDE EXCAVATION AND RESTORATION FOR INSTALLATION OF TRANSFORMER VAULT PER PUGET SOUND ENERGY REQUIREMENTS. PUGET SOUND ENERGY SHALL PROVIDE AND INSTALL TRANSFORMER VAULT AND PAD —MOUNT TRANSFORMER. PUGET SOUND ENERGY SHALL TERMINATE CONDUCTORS ON BOTH PRIMARY AND SECONDARY SIDE OF TRANSFORMER. TRANSFORMER FRONT SHALL FACE WEST. TRANSFORMER SHALL HAVE 10' OF CLEARANCE IN FRONT OF TRANSFORMER AND 3' OF CLEARANCE ON SIDES AND REAR OF THE TRANSFORMER. 4. PROPOSED SECONDARY POWER SERVICE, HCONTRACTOR SHALL PROVIDE TRENCHING, BACKFILL AND RESTORATION. CONTRACTOR SHALL PROVIDE AND INSTALL CONDUITS AND CONDUCTORS FOR SECONDARY POWER SERVICE PER TYPICAL TRENCH DETAIL, SEE DWG N0. E06. XXX 5. SEE DWG N0. E02 FOR CONDUIT/CONDUCTOR SCHEDULES. 6. INSTALL CONDUIT UNDER ROADWAY PER PUGET SOUND ENERGY AND KING COUNTY STANDARDS. PROVIDE TRAFFIC CONTROL AS REQUIRED. PROPOSED ASPHALT CONCRETE PAVING, BY OTHERS EXISTING ASPHALT CUT LINE, CONTRACTOR SHALL STAY WITHIN EXISTING CUT LINES CD w Q> Cr(n MEN 00 CD I Q O z�v a - SAND BEDDING MATERIAL PER WSDOT SPECIFICATION 9-03.13 NATIVE MATERIAL COMPACTED TO 95% PER ASTM D1557 OR AS REQUIRED PER PLAN EXISTING ASPHALT PAVING NATIVE MATERIAL COMPACTED TO 95% PER ASTM D1557 OR AS REQUIRED PER PLAN J, 0.0.0.0.0.a.\\ \ /\/\\/\\ PROVIDE 4 COMPACTED DEPTH OF \\/ o,' /\//\//\// / \ 5/8—MINUS CRUSHED ROCK, COMPACTED / \ /\\\/\\\/\\\/\\/\\/\\ \\\ ' TO 95% MAXIMUM DENSITY OR AS 9" /\ (30 0 o a o o //\//\//\//\//\//\//\� REQUIRED PER PLAN /\\\/\\/N RED ELECTRICAL WARNING TAP 6" MI \ 3 MIN „ 6" MIN 3" MIN \//\//\//\//\// \ CENTERED OVER EACH CONDUIT IN TRENCH (TYP ) lo 3" MIN \ /\\\/\\\/\\/\\\/\\\/\\ �� PRIMARY SERVICE ELECTRICAL CONDUIT. SUPPLIED AND INSTALLED BY PSE ELECTRICAL CONDUIT ///\///\//j//j//j///\// EXISTING 12 SEWER 3' M I N DETAIL 03 TYPICAL TRENCH DETAILS. NOT TO SCALE NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION. UNDERGROUND PRIMARY POWER SERVICE. MAINTAIN SEPARATION TO OTHER UTILITIES PER PSE REQUIREMENTS AND DETAIL BELOW. ELECTRICAL SIT-E PLAN 1 2) = 20) RED ELECTRICAL WARNING TAPE CENTERED OVER EACH CONDUIT IN TRENCH (TYP) 3" MIN DETAIL 5' W X 7' L PRIMARY POWER PULL VAULT PROVIDED AND INSTALLED BY PSE. CONTRACTOR SHALL PROVIDE EXCAVATION, BACKFILL, AND RESTORATION FOR INSTALLATION OF PROPOSED VAULT. SEE PHOTO A THIS SHEET FOR MORE INFORMATION. RESTORE SURFACE TO EXISTING CONDITION OR BETTER PER PLAN. ROADWAY SECTION ON SCHOOL PROPERTY SHALL MATCH EXISTING ROADWAY SECTION SAND BEDDING MATERIAL PER WSDOT SPECIFICATION 9-03.13 EXISTING 12" SEWER NOTE: EXISTING 1 1/2" Al PVC CONDUIT x } 16727 "`�jQNAL SIGNED: 05123112 ►''" MLA of WAS � 38613 -"kG79TE4�9 SIGNED: 05123112 NOTE: EXISTING 4" PVC WATER MAIN �r �-- UGP UGP C EXISTING ASPHALT ROADWAY SURFACE Q �o p P A LLI - I � �u co to Cr Faft Waft --� 4 C) M cc ` L r c� T J W Uj C 2 - a S' A C_ 0 3 Wp �o r!,—NGINEERS LANNERS EXISTING OVERHEAD <77" I E N T 1ST S PRIMARY POWER SERVICE RH2 ENGINEERING, INC. http://www.rh2.com mailbox0rh2.com 1.800.720.803z BELLINGHAM 360.676f,:° 454 West Horton Road BOTHELL 425.951.5400 22722 29th Drive SE, Suite 210 EAST WENATCHEE 509.886.2900 300 Simon Street, Suite 5 RICHLAND 509.946.5181 114 Columbia Point Drive, Suite C SILVERDALE 360.876.79W 2021 NW Mhyre Rd, Suite 107 TACOMA 253.272.3OS9 621 Pacific Avenue Suite 104 SCALE: SHOWN 0 1" 2" DRAWING IS NOT TO SCALE _ IF BAR IS NOT 2" LONG RECORD DRAWING PLOT: 20 DWG N0, REVISED TO CONFORM ENGINEER: CCA E02 TO CONTRUGTIO RECORDS REVIEWED: MLM 04/25/12 DATE. Jul 23, 2013 s"E- 9 RH2 RING INC. DATE CLIENT: REN REVISED TO CONFORM TO CONSTRUCTION RECORDS AHF EH 04/25/13 Joe No.: 112-033 NO. REVISION BY REVIEW DATE FILENAME: LIBHS—D—EO3.DWG r �z O N o_ N