HomeMy WebLinkAboutWWP2703633.2z O z w x w Of w w to Q J z O J 0 O I- Ld lii Q Z U L►I 1 O d \N �TO SEWER BOLTHOLES - 3 PLCS EQUALLY SPACED 120° APART 3N 23 I/i6' <586mm) DIA B,C (SEE DETAIL) COVER & FRAME PLAN VIEW 25' DIA, Lo35mm] -1 1' _; 9mmJ I 8 3/ 4' L 2 1/2' 222mml L64rrrIJ TYP COVER SECTION VIEW 26 112' DIA L673mm] 25 1/4' DIA L6411mm] -1/4' (6mm) DIA NEOPRENE GASKET I . L15{ mroJ 5/8" ( 23 3/8' DIA CL OPEN 1 1 L.6mmJ L594mm] 27 5/16' DIA L694mmJ 34 1/8' DIA COVER BOTTOM VIEW ELT SOC. CALLEN HEAD) 5/8'-11 X 1,5 SS ?Z BBER WASHER EON BOLTING DETAIL 1/4' C6rA- GASKET1/16' 1/8' j CR3mn] GROOVE DETAIL L867mmJ NOES: FRAME SECTION VIEW 1. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. ,ISE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). S STD. PLAN - 401 PUBLIC WORKS MANHOLE ( FRAME AND COVER ism j a DEPARTMENT -- DECEMBER 2008 l MANHOLE FRAME AND COVER ' SEE STD. PLAN 401 24" T ADJUSTMENT RINGS 12- MIN-) 12" MAY SEE NOTE 6 MORTAR JOINT(S) (3/8' MiN-) SEE NOTE 5 D f' - GONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 STEPS - POLYPROPYLENE STEPS SHALL BE 1^JCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL, LADDER- POLY?ROPYLEN E SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE - 'E' CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. NOT TO SCALE A, S. ,C, D, 'Ei 48 MH 48" 6" MIN. 5"MIN 24" MIN. 21" 1. D. 1 54" MH 5A" 8" MIN. 5.5" MIN. 24" MIN. 24" LD. 60" MH 60" j 8" MIN. 6" MIN. 42" MIN. 30" 1. D. NOTES: 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS ARE TO BE 1N PLACE BEFORE MANHOLE SECTIONS .ARE INSTALLED. 3 CASTING SHALL BE PER STD. PLAN 401. A. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ALL JOINT` BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. 6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY, BRICKS SHALL BE STAGGERED TO CREATE A. RUNNING BOND OR 112 BOND, ]JAL USE OF SHIMS IS PROHIBITED. 7. SANITARY SEWER MANHOLES SHALL HAVE AL INTERIOR SURFACES, INCLUDING CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIEL4 OR APPROVED EQUAL. COLOR OF COATING SHALL BE WHITE. 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WiTH ASTM C-443- 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. 10. CONNECTIONS TO MANHOLE SHALL BE MADE JSING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. 11, IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A. MAXJMUM OF 19" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVEC AREAS, COVER MUST SLOPE IN AL DIRECTIONS TO MATCH PAVING. STD. PLAN - 400.1 PLBIJC WORKS STANDARD SANITARY MANHOLE 1 DEPARnMINT A�j�o I SE:PTEMUR 2011 SW 1/49 NE 1/4 SECTION 15; TOWNSHIP 23 N., RANGE 5 E., W.V. i ALL 90' TURNS SHALL BE ACCOMPLISHED BY MEANS OF A 'NYE AND 45' BEND. TWO 45' BENDS SHALL NOT EE ACCEPTABLE- 4" 4" BEND AS REQUIRED (NO MORE THAN 45' REND). EVERY 2ND 4" CLEA.YOUT WYE NTH CHANGE IN DIRECTION OR GRADE 45• EENri AND PLUG. WILL REQUIRE A SURFACE CLEANOUT WYE. I� � � �• ��� w w � J . M. w HOUSE HOUSE a HOUSE ^ al o) H U5c z � � i 3 -0" MIN. 4" EWER PIPE 14" SURFACE ��(TYPiCAL) CLEA, IC -UT 4" SEWER PIPE, SEE NOTES 2 WYE' 4" TEST TEE WITH AND 3. UINIAAU)A LINE SIZE FOR I �'„ CPLUG FACE UP OTHER THAN SINGLE FAMILY IS 6' LEANCUT 1 PROPERTY UNE 'AnWITH PLi i3 (TYPICAL) PROPERTY UNE C.,i 3' MIN cy �-6% 4" REDUCER � F F F (TYPICAL) F D MAIN SEWER LINE � w NOTES: 1. Prfor to Installation of a sar:itary sewer connectior, a side -sewer z IF THE BUILDING SEWER SERVES ANY' nMRE HAVING permit must be purchased from the City of Ren=on Public 'Norks X R FLOOD LEVEL RIMS LOCATED BELOW' THE ELEVATION Department. o OF .HE NEXT, UPSTREAM MANHCLE COVER OF THE PUBLIC SEWER SYSTEM, A oACK.ROW PREVENTION 2. Types of pipe and fittings that can be used for sanitary sew>s o ? DEVICE SUCH AS CLEAN CHECK EXTENDABLE P p y e BACKWATER VALVE OR A°PROVED EQUAL SHALL i?E shall be approved by the Department of Public Works. Rubber or ' m INSTALLED. neoprene gaskets as specified by the manufacturer, shell be used on aoirts. 4" FLEX`ELE CCUPLING (FERNCO OR EQUAL) 3. A minimum grade of 2% (1/4" per foot) must be maintained w SURFACE CLEANOUT with 4" pipe. in the ever: a 2% grade cannot be maintained, the 4"t 4. z4„ WY owner must sign a City of Renton grade release form and tV : gt _ can Instcil 6" pipe a grade of ?% `- 4" P'o INs PLAN 4. For iri ctior of side sewer, call 24 hours in advance. The BUILDING DRAIN FOR inspection phone number is or. the side sewer permit. Site LOW ELEVATION HOUSE must be reedy for inspection and representative on site wher inspector arrives at appointed time. Side sewer and stub shall be tested per City specifications 'Make the connection at the MAIN TO PROPERTY UNE 5'-0" 5-0. hot sa Da not hack`ill the ditch untt approval is given by the PROPERTY UNE FROM THE HOUSE BUILDING DRAIN inspector. Final approval will be granted after the existing septic DE SEWER BUILDING SEAEP 2'_6" tank has been pumped out and filled with sand. TO 3'-)" -3-0"MIN. 5. Install side sewer with 2 minimum cover. 18" cover is allowed I \ _ at ;he house if cutlet is sbdfow. a f side sewer stub is not available. The owner shall be l A A responsible for Its installation per standard drewing 406.1, All mm - to �z0z m m p _iA a � : m r�l C m z i*t = x - > x• work within street right-of-way shall be done cy a licensed c: d y '� o� c; z m __U z r'i `n bonded contractor. zo v,0-v m cnmo p�- a o O m p Z -> 2 C _� C x c- r- .- n A i F�� cn o A m m M y N z o '-., > C m c 1. All work shall be aeeompl;shed in accordance with the Washington m y C8 r m xA � zo m r� Industrial Safety and Health Act. (WISHA) + z"�4 �z' vizx t 8 5 p-, I -4 Io _U p r 61 o r + D 8_ All trench restoratior fcr side sewers in the public right-of-way M _4 = z� 1,mZo 0� z shall conform to tho most current trercf; restoration. n z om c requirements as in the Renton 5tandcrd Oraw,6tgs. x rn x - Z ZI o a, Opm O w 9. All building sewer and side sewers shall have bedding ir cn 5 y accordance with standard drawing 405. el - D 'D -a x z i x m 10. There shall be a minimum "D foot horizontal separation between o Y, m scnitory side sewers and water services and a m nim:im 5 toot C horizontal separation between sanitary side sewers and jjj other P Z, utilities. c CALL FOR LOCATONS BEFORE YOU DIG 48HR LOCATORS 1-800-424-5555 TYPICAL BUILDING SEWER STD. PLAN - 406.2 PUBLIC WORKS FROM PROPERTY LINE TO DEPARTMFNT BUILDING CONNECTION SEPTEMBER 2011 (SEE NOTE 4) 3LDDING MATERIAL FOR SANITARY SEWER PIP[ (SEE NOTE 6) FOUNDATION LEVEL LiMI-1S Or- PIPE ZONE V-p„ O.D. OF PIPE BEDDING I OR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUP'OR1 UNDER BARREL_ 2. HAND -AMP UNDER 'LAUNCHES. 3. COMPACT BEDD NG MATERIAL 10 95% MAX- 7-NSITY EXCEPT DIR_C OVER PIPE. HAND TAMP ONLY. 4. SEE "EXCAVATION AND PREPARATION OF TRENCH" 1N THE SANITARY SEWER SECTION OF THE STANDARD SPECIFICATIONS FOR TRENCH WIDTH "W * AND TRENCHING OPTIONS. THE PiPE ZONE WILL BE THE ACTUAL TRENCH WIDTH. 5. 7R7NCH BACK.,ILL SHALL CONFORM TO "BACKFILLING" IN FH?E SANITARY S`-'NER S" CTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PiPF DIAMETER SHALL NOT BE USED IN THE BACKFILL MATERIAL. 6. PIPE ZONE MATERIAL SHALL 8F "GRAVEL BACKFILL FOR DRAINS AS SPECIFIED IN THE AGGREGATES SECTION ')F THIF STANDARD SPE CIFlCATIONS. 7. PIPF MUST BE ANCHORED 1N SUCr- A MANNFR AS TO ENSURE FLOW DNE IS VAINTAfNED. PUBLIC WORKS PIPE BEDDING STD. PLAN 405 DFAlt'I u_'NT FOR SANITARY SEWERS MARCH 200I3 REVISION 6" BUILDING SEWER PIPE TEE WITH 6" SIDE CUTLET 6" SIDE SEWER AND_6UILJING SEWER 1:3:5 MIX CONCRETE BLOCKING PROFER'Y LINE 3•-�>' i FUTURE BUILDING SEWER `2''x 4" STUD MARKING POST PAINTED 5"X6"Xb" WYE 'WHITE WITH THE WORD "SEWER' STENCILED SURFACE CLANOUT YdiTHCe IN 3" HIGH BLACK LETTERS AND WIRE w CAST IRON RING &COVER WRAPPED ARCUND THE STUD AND. E a.. (EAST JORDAN IRON WORKS C EXTENDED TO THE TOP OF THE STLID. 2975 OR APPROVED EQUAL. SPECIFY "SEWER" ON LID, SEE STD PLAN 4-03.1 FOR INSTALLATION) ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN LINES ARE AS FOLLOWS- A- ATR11IED CLAY MAIN - CUT IN A NEW TEEE USING FLEX,8LE COUPLINGS (FERNCC OR APPROVED EQUAL)- B. CONCRETE MAIN - CORE -DRILLED M r-i A ROMAC SADDLE (OR APPROVE EQUAL;. C- PV(; MAIN - CORE -DRILLED WiTH A ROMAC SADDLE. (OR AP -ROVED EQUAL) OR CUT 1N A NEW TEE USING RIGID COUPLINGS. J- OLI-TILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E- VANH=- CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -CUTS OR THE STRUCTURE SHALL BE CORE -DRILLED. 60" ALLOWABLE MAX - FOR CAST IRON PIPE OR DUCTILE iRON PIPE. 6" SIDE OUTLET TEE SEWER MIN. MAIN CONCRETE BLtiCKIVG ANGLE OF TEE hT MAIN OVER 25 ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LIVE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER 1S LOWER. `1 NG�F CO 2% MiN SLOPE HORIZONTAL -� Vi MAIN TYPICAL SIDE SEWER ELEVATION Y PitBLIC WORKS STANDARD SIDE SEWER INSTALLATION r �•: DEPARTMENT (SEWER MAIN TO PROPERTY LINE) N/A ASP ol+v�lt ASP - - CHMM -- BY DATE A PR APPIi01lED'-- ':,''I:ERGPOUND PIPE LOCATIORI BASED ON SURFACE FEATURES. ACMAI u"'K1 ON MAY WRY. f NP RM ``'HAT THB LOCATIONS, ELEVATIONS, DEPTHS, AND AS -BUILT ► I!F1LXT ING 1•tA'TL,R1Al.a ACTUALIY USED DUR.INO ti fiPi1-"1 ••�•�, ACf`?1Fr.`1Pt v REJ i Et':S E.J. i FIELD COPiDTTIONS r MY OIRFr'T r i.P`.fr InNONTHIS CHECKED FOR COMPLIANCE TO CITY STANDARDS Date Date Date SEPTEMBER 2011, RECOMMENDED FOR APPROVAL BY- BY - BY Utility Specifications Sanitary Sewer Notes and Specifications THESE NOTES SHALL APPEAR ON PR03ECTS FOR THE WASTEWATER UTILITY. 1. All work and work material shall be in conformance with the standards and specifications of the City of Renton Planning/Building/Public Works Department and the latest edition of the WSDOT/APWA Standards and Specifications, as approved and modified by the City of Renton in the Renton Standard Plans & Specifications. A set of approved plans shall be kept on site at all times during construction. 2. The hours of work in the street right of way shall be per City specifications on weekdays unless otherwise approved in writing by the Planning/Building/Public Works Department. An approved traffic control plan must be obtained prior to beginning any work within public right of way. 3. All locations of existing utilities shown are approximate and it shall be the contractor's responsibility t0 verify the true and correct location so as to avoid damage or disturbance. 4. A pre -construction conference and a 24 hour notice shall be required prior to starting new construction. It shall be the contractor's responsibility to secure all necessary permits prior to starting construction. (Inspection will be accomplished by a representative of the City of Renton.) It shall be the contractor's responsibility to notify the Public Works inspector 24 hours in advance of backfilling all construction. 5. Contractor is solely responsible for the means, methods and sequences of construction and for the safety of workers and others on the construction site. 6. It shall be the responsibility of the contractor to obtain street use and any ether related permits prior to any construction. 7. Plans approved by the City of Renton, Public Works Department shall take precedence over all other plans. 8. A copy of these approved plans must be on the Job site whenever construction is in progress. 9, The contractor shall provide the City of Renton with an as -built drawing of the sanitary sewer system, which has been stamped and signed by a licensed professional engineer or licensed professional surveyor. 10. Backfill shall be placed equally on both sides of the pipe in layers with a loose average depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95 percent of maximum density. These compacted layers must extend for one pipe diameter on each side of the pipe or to the side of the trench. Materials to complete the fill over pipe shall be the same as described. 11.Open cut road crossings for utility trenches on existing traveled roadway shall be backfilled with crushed rock and mechanically compacted unless otherwise approved by 12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise approved by the City of Renton Public Works Department. Reference benchmark and elevations are noted on the plans, 13. All disturbed areas shall be seeded and mulched or otherwise stabilized to the satisfaction of the Department for the prevention of on -site erosion after the completion of construction. 14. All pipe and appurtenances shall be laid on a properly prepared foundation in accordance with the standards and specifications of the City of Renton Planning/Building/Public Works Department and the latest edition of the WSDOT/APWA Standards and Specifications, as approved and modified by the City of Renton in the Renton Standard Plans & Specifications. This shall include necessary leveling of the trench bottom or the top of the foundation material, as well as placement and compaction of required bedding material, to uniform grade so that the entire length of the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be pea gravel 6 inches above and below the pipe. 15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034, SDR 35 (color shall be green) or ductile Iron class 50, unless otherwise approved by the Wastewater Utility. 16. In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches above finished grade or must have minimum 2' diameter concrete ring poured at grade. In paved area, cover must slope in all directions to match paving. S 363304 4W qr Sy/��F� 14 it �1 �o 28352 O IFS /SI S�0 A L :;TAMP NOT VALID UNLESS SIGNED` DATED 1 1 1 DALEY-MORROW-POBLETE, INC. 726 AUBURN WAY N. AUBURN, WASHINGTON 98002 PHONE: 253-333-2200, FAX: 25-7 773 -2206 Q \ ENGINEERING - SURVEYING J LAND PLANNING incorporated gala - AS SHOWNHORNINTINiL WO IN 137 ,, CITY OF - - R E N TO N SE. 2ND ST. DATUM ow INCH Planning/Building/Public Works Dept. IF NOT ONE Nqi SANITARY SEWER NOTES AND DETAILS 9CME ACCOPWPWY cic t MAY. 2, 2012 Fi88BOi]K: PnaE I]RIINNC lNOe 11165S a1F 2 1 �I