Loading...
HomeMy WebLinkAboutWWP2703636.1N r` om �� z N 0 a 3 < r c— I I I I I I I D:1 L�_ w DL� Z Z Y O LL LL LL N LIJ 04 N Q do L) O LL_ L- w w m I__D CITY OF RENTON NO. 806 FOUND MON. IN CASE A PORTION OF THE N. W. 114 OF THE S. W. 114 OF SECTION 10, CITY OF RENTON, STATE OF WASHINGTON N.E. 6TH PLACE I I I I T.L. 102305-9282 I w i z w Iz Q � z O z i i i T.L. 102305-9286 72'-6" PVC ® 13.00% EX. 6' CYCLONE FENCE 5' PRIVATE SIDE SER EASEMENT FORT.L. 02305--9285 T.L. 102305- 9282 6 z 0 0 1 OQ% f INV=396,37 r� ----------------------------------- 1M10'-6" PVC _® C.U. 2.00% INV=39615 J, N� / 104'-6" PVC ® 2.00% J J � 1 � I o o' IU LLj i I I En w Q 1 1w w I �/ I ~ ; o 0 ' > SSMH# 1 I>. I a RIM=405.3E #t'A Z8 12' WIDE GRAVEL (MATCH GROUND SURFACE) INV=392.98 (E) ROAD ACCESS 39M,i „ w� INv=392.88 (SW) I I; a o 0 ��Z•�� STA. 0+6? PVC' I �nL r — - T.L.102305-9282 I ~ ~ J�'IDESEWER FOR T.L1 I .. ;N ----EX,_4'-WOOD RAIL FENCE '- \ 1 ' - L--- — - �� —o- I I --I TRACT 'C' OF VINEYARDS II —��== 075'-8" PV^ ®1.0 REC. NO. 20030305000057 , f6';'SANITARY EX. SSMH -EX. PAVING^ ..... SEWER r RIM=405.82 1 (EASEMENT INV=3923%2 (8"PVC-N&S) I t o ........ ..�N o 3 G '� GAS METER- i ..... 16`-8"1 PVC ® 1 00% ..I......... 77711 REMOVE EXISTING 5'^-8" EX. HOUSE cn PVC STUB ® 0,50% U_ � T.L. 102305--9446 �I l I EXISTING 15' SEWER EASEMENT j� ++ REC. NO. 20040625000526 T.L. 102305-9445 ►y 410 CITY OF RENTON NO. 15C FOUND MON I CASE 400 DATUM NAVD 88 BENCHMARK a Z m m w � Z CITY OF RENTON NO. 1503 :E _0 1/8" COPPER PIN IN A CONCRETE POST MONUMENT, DOWN 0.7', j IN A MONUMENT CASE AT THE CONSTRUCTED INTERSECTION OF N.E. 4TH STREET AND UNION AVENUE N.E. >_ Lij m ELEVATION=401.01 FEET 390 J Q U m — m W m a V71 Z ctfo -i> DATUMELEV >-Lj Qf 385.00 rb N Z Ln p STA. 0— + 5 — CLEANOUT PER C.O.R. STD. PLAN NO. 403.1 -- _JhI2V=_3R3.73 — c. TRACT A \-------- --------- .....-.--.-__-.-,-- - \ \ \ I � I PVC ® 7j5`,18" PVC o r — - - 1-00% SSMH# 1 RIM=405.3f g195.Zr. -- - (MATCH GROUND SURFACE) - EX. SSMH-- INV=�92.98 (E) 3C( $� RIM=405,82 INV=392.88 (SW) 3� - V-39? (8"PVC-N&S) 311,bj (ti) SEWER PROFILE 3�2•(tPy 5� 1 "=20' HORIZ. "=5' 1 VERT. 10 O ,' O d OJ cy) n T.23N., R. 05E., W.M. T.L. 102305-9284 z 0 5 10 20 SCALE 1 " = 20' 10' PRIVATE SIDE SEWER EASEMENT FOR T.L. 102305- 9284 KEcc. a Z IDLZ. 05G zoo 1095 -4F STA. 0+-.1;5 CLEANOUT PER C.O.R. PLAN NO. 403.1 —INV=393.73 QCo t_p vol c,64Ec�J THESE PLANS ARE "AS -BUILT" AND THE INFORMATION SHOWN ACCURATELY REFLECTS EXISTING FIELD CONDITIONS AS OF THIS DATE: , ?-11,q l3 f , WILLIAM SHOPE HI0LMBERGV*LS 11332 I i I I I I I I I S=363606 �r36r3�60 1 RECOMMENDED FOR APPROVAL �i 8'Y —�.� • / �/ IBY BY CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE DATE DATE UTILITY SPECIFICATIONS SANITARY SEWER NOTES AND SPECIFICATIONS THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WASTEWATER UTILITY. 1. ALL WORK AND WORK MATERIAL SHALL, BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF' THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS D'_.'ARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE: CITY OF RENTON IN THE RENTON STANDARD PLANS & SFECIFICATIONS. A SET OF APPROVED PLANS SHALL. BE. KEPT ON SITS AT ALL TIMES DURING CONSTRUCTION, 2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE PER CITY SPECIFICATIONS ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT. AN APPROVED TRAFFIC CONTr:^L PLAN MUST BF 09TAINED PRIOR TO BEGINNING ANY WORK WITHIN PUBLIC RIGHT OF WAY, 3.ALL LOCATIONS OF' EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE -IHE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION FO AS TO AVOID DAMAGE OR DISTURBANCE. 4.A PRE -CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE 'HALL BE' REQUjR7D PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON) IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE PUBLIC WORKS INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL. CONSTRUCTION, 5.CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES Or CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND nTHERS ON THE CONSTRUCTION SITE. 6.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. T PLANS APPROVED BY' THE CITY OF RENTON, PUBLIC WORKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL. OTHER PLANS. 8.A COPY OF THESE APPROVED PLANS MUST BE ON THE: JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. THE CONTRACTOR SHALL. PROVIDE THE CITY OF RENTON WITH , N AS -9111T DRAWING OF THE SANITARY SEWER SYSTEM, WHICH HAS BEEN STAMPED AND SIGNLD .+ LICENSED PROFESSIONAL_ ENGINEER OR LICENSED PROFESSIONAL SURVEYOR. 10. BACKFILL SHALL BE PLACED EQUALLY" ON BOTH SIDES OF THE PIPE IN I AYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES, MAXIMUM DEPTH OF 8 INCHES, I:10ROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY, THESE COMPACT.) I_AYERS MUS F EXTEND FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO TLI _ SID- C.- THE TRENCH. MATERIALS TO COMPLETE THE FILL. OVER PIPE SHALL. BE THE SAME AS DESCRIBED. 11. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELL : ROADWAY SHALL BE BACKFILLED WITH CRUFHED ROCK AND MECHANICALLY COMPACTED UNLESS OTHERWISE APPROVED BY 12. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 MET_r' AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 MFT7-RS UNI ''SS OTHERWISE: APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 13. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHER'VI :.- STABILI7_E0 TO I" _ SATISFACTION OF THE DEPARTMENT FOR THE. PREVENTION OF ON -SIi= EROSION AFTER „ COMPLETION OF CONSTRUCTION. 14. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE STANDARDS AND SPECIFICATION-. OF THE CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS DEPARTMENT AND THE LA IEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE RENTON STANDARD PLANS & SPECIFICATIONS. FHI� SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF TLI-_ FOUNDATION MATERIAL, AS WELL AS PLACEMENT ,AND COMPACTION OF REQUIRED BEDDING MAi _RIA'_, FO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL. BE SUPPORT::-) ON A UNIFORMLY DFNSE, UNYIELDING BASE, PIPE BEDDING SHALL BE PEA GRAVEL 6 INCHES A,; (, _ AND BELOW THE PIPE. 15. SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC) RUBBER GASKETED ASTM D 3034, SDR 35, OR DUCTILE IRON CLASS LO, UNLESS OTHERWISE APPROVED BY TH WASTEWATER UTILITY. 16. IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 INCHES AN-) MAXIMUM 12 INCHES ABOVE FINISHED GRADE OR MUST HAVE MINIMUM 2' DIAM_T'_R CONCRETE RING POURED AT GRADE. IN PAVED AREA, COVER MUST SLOPE IN AL.L. DIRECTIONS TO MATCH PAVING. Call before you Dj g. 1-800-424-5555 AVOID CUTTING , 'InERGROUND UTILITY LINES. IT'S COSTLY P► M Eq 4'# G of wAsy/ 4 U co - Z� 9F38285� <� - _ NOTE: EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY. IT SHALL BE THE: CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER-- GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOW" IN THEIR PROPER LOCATION, CALL. BEFORE YOU DIG: 1-800-42-4-5555 UNDFRGROUND SERVICE (USA) a�I -3-3(f,34�01 Y \Jobs (J)\10\10593 MADISON PLACE\10593 CAD\dwg\1673-028-ENG.dwg 09/19/11 01:47:26 PM PDT