Loading...
HomeMy WebLinkAboutSWP2703639.7M M N I a. 3: r v/ i N=181811.10 E=1296841.87 El FV.=187.02 Q o� I I -I ,96 0 as 0 z cV � �¢ O o I w L nrh vZ N I­__J0 n co a_� Q U F LLI O OUO o2� w �� /L / - Wo 3: 3: = O I x J 2 o a O = x CF 0 a j JLn 181820.80 I, �aoi in2 / �� E= 97091.43 EL V. —16 0. 61 I Q LO �' o w r10— _ � oDe ti2j I I SS 6"Conc Of to LLJ N o I I o- O = I m o cn 11 i 13 ¢ 0 IWT,A �� 21+0 I --�—� ►N LO _ I CJI 2�+00 v I,I � "STL WM o/ _*Abnd 4'STL WM Loc APPx �Abnd 411 (:k 'MHEDGE �00 o6'CHp1NLINK FENCE OD o o— o d EXTRUDED CURB 0 Q 6638-3.1cPRiC i RENTON ST ROW IL 3 N=181814.45 — co 00 c�1 I E=1296979.01 I Q c� m FI FV.-174.80 I o of C1i n in n RECOMMENDED FOR APPROVAL BY Daniel Carey 9/6/12 BY Wgsti�y� V) 0z \FGxxxxx / STERF�/ ORIGINAL PLAN STAMPED AND SIGNED 9/7/12 BY: RONALD J. STRAKA PE# 29727 2 US 0 N I� I o I-0 o l I I \ I ® \ II I o w I = 0fn Ui O N ® + I (c) Lo I nn re) I IFY(n I = U'z M Q i I I U REVISED CB-6 S 12" IE TO MATCH SHT 4 DWC 11/15/12 DWC SURVEYED: PACE E ADDED AS -BUILT INFO, REMOVED OLD DESIGN INFO, I DWC CLEANED UP DRAWING, REMOVED SOME CONSTR INFO, NOTES. REVISION ngr DESIGNED: 12-13 DWC DWC DRAWN: DWC CHECKED: RJS, DWC DATE APPR APPROVED: RJS SCALE: As Noted ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY CALL 48 HOURS BEFORE YOU DIG 1—8004245555 EXISTING UTILITY LOCATIONS ARE APPROXIMATE, NOT ALL UTILTIES MAY BE SHOWN. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES. GENERAL NOTES 1. ALL TYPE 2 CB'S SHALL BE RING AND COVER UNLESS NOTED OTHERWISE. 2. ALL TYPE 1 CB'S SHALL BE FRAME AND GRATE UNLESS NOTED OTHERWISE 3. ALL CB RIMS AND GRATES SHALL MATCH EXISTING GRADE (SHOWN AS _). 4. SEE TRAFFIC CONTROL BID ITEM FOR WORKING HOURS AND CONDITIONS. C = PLUG EX PIPE CONSTRUCTION NOTES O1. TEMP EROSION CONTROL: INSTALL CATCH BASIN FILTER FABRIC AT ALL EX CB'S INSTALL SILT FENCING IN ROW BELOW CONSTR AREA. O2 2. PROTECT/SAVE ANY EX WOOD CRIBBING, LANDSCAPING, MAILBOXES, SIGNS IN WORK AREA, NEXT TO EX CB's. RESTORE AFTER CONSTRUCTION. 3. DO NOT BLOCK DRIVEWAYS EXCEPT WHEN INSTALLING NEW STORM SYSTEM IN FRONT OF THEM. 4. PROVIDE TEMP STORMWATER BYPASS/PUMPING AS NEEDED. AS -BUILT NOTES Ol 1. CHANGES, ELs NOTED "AB". TYPICAL TRENCH BEDDING AND BACKFILL ( ALL SHEETS) (NTS) TRENCH EXCAVATION PAY LIMIT 5'-0" MAXIMUM SEE DE TAIL FOR PA VEMEN T PA TCH BACKFILL MATERIAL WSD 0 T SECTION 9 — 03. 19 BANK RUN GRAVEL, OR NA T1 VE MA TERIAL IF I T MEETS SPECS. PIPE ZONE MATERIAL WSDOT 2006 SECTION 9-03.12(3) GRA VEL BACKFILL FOR PIPE ZONE BEDDING NEW UTILITY PIPE EXCA VA T10N OF UNSUI TABLE SOIL (IF NEEDED) DEPTH AS APPROVED BY ENGINEER BACKFILL WITH FOUNDATION MATERIAL MEETING WSDOT SECTION 9-13.6 QUARRY SPALLS NO TES 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. J. COMPACT PIPE ZONE MATERIAL TO 957o MAXIMUM DENSITY EXCEPT DIRECTLY OVER PIPE WHERE COMPACTION WILL BE HAND TAMP ONLY. 4. PIPE MUST BE ANCHORED 1N SUCH A MANNER AS TO ENSURE THAT THE FLOW LINE 1S MAINTAINED. D=363907 AS -BUILT SURVEY BY: OTouma Engineers and Land Surveyors Dan M Touma, PLS #38992 AS -BUILT As -built Survey Plans Stamped 4/22/2013 DATE: VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 �.= STEVENS AVE NW / LIND AVE NW 9-7-2012 CITY Y O F STORM SYSTEM IMPROVEMENT PROJECT FlELDBOOK: R E N TO N PAGE. t DATU M DRAWING NO: Planning/Building/Public Works Dept. RENTON ST ROW 3 SHEET: OF: 5 ' D 3639.