Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutWWP2703643.43
0
U
(D
ry
I
f3f
� a
€
a
3
•
3 G
� r
.. .......
.. ......... _.: ..... _
..,, ...T.. «..
_.. _ _,___ ,:: :
ROCI
A `�U..MNA
C.
w
# ST
fi„ .::..::::::....
Z
t
4 OF SW 1/4, SIB =,TION 3, TOWNSHIP 23N, RANGE 5E, W.M.
€'N j' = . 2 r . .
GRAPHIC SCALE
0 10 20 40
( IN FEET )
1 inch = 20 ft.
:;.E . `'
3
N
',A 88
L-- MND:
6" GREASE WASTE
6" WASTE WATER
GREASE INTERCEPTOR
SANITARY SEWER CLEANOUT/TEST TEE
6" GW
6" WW
a
a
SANITARY SEWER
SCHEDULE
❑1
INSTALL NEW 6" CLEANOUT.
16
38 LF 6" PVC SDR 35 GW ® 2.0% MIN.
RIM = 400.0
NEW 6" I.E. = 392.9E
17
SANITARY SEWER CLEANOUT
RIM = 398.79
22b
23 LF 6" PVC SDR 35 WW ® 2.0% MIN.
IE = 396.00
❑3
61 LF 6" PVC SDR 35 WW Cal 2.0% MIN.
18
20 LF 6" PVC SDR 35 GW @ 2.0% MIN.
®
SANITARY SEWER CLEANOUT
19
SANITARY SEWER CLEANOUT (SURFACE)
RIM = 398.62
RIM = 398.89
IE = 394.58
IE = 396.40
SSCO TO BE PLACE A MAX. 5 FROM BUILDING
❑5
WYE CONNECTION
20
2 LF 6" PVC SDR 35 GW @ 2.0% MIN.
IE = 394.78
©
57 LF 6" PVC SDR 35 WW ® 2.0% MIN.
21
6" GREASE WATER ENTRY APPROX. I.E. = 396.44
7 ❑
SANITARY SEWER CLEANOUT
.IERIM
RI - 98.
98. RIM = 374
22
SANITARY SEWER CLEANOUT
= 398.90
IE = 393.36
®
14 LF 6" PVC SDR 35 WW ® 2.0% MIN.
❑9
SANITARY SEWER CLEANOUT (SURFACE)
RIM = 398.88
23
4 J:: PVC SDR 35 WW ©1.0%
24
SANITARY SEWER CLEANOUT
IE = 396.00
SSCO TO BE PLACE A MAX. 5' FROM BUILDING
RIM = 398.33
IE = 393.83
10
2 LF 6" PVC SDR 35 WW ® 2.0% MIN.
25
100 LF 6" PVC SDR 35 WW ® 1.0%
11
6" WASTE WATER ENTRY
APPROX. I.E. = 396.04
26
SANITARY SEWER CLEANOUT
RIM = 398.19
IE = 394.83
12
12 LF 6" PVC SDR 35 GW @ 2.0% MIN.
27
88 LF 6" PVC SDR 35 WW ® 1.0%
13
SANITARY SEWER CLEANOUT
RIM =
IE = 395.02 02
28
SANITARY SEWER CLEANOUT
WITH A ROMAC COUPLER
RIM = 398.50
IIE = 395.70
14
4 LF 6" PVC SDR 35 GW @ 2.0% MIN.
WITH SANITARY SEWER TESTING TEE
RIM = 398.18
29
15 LF 6" C900 WW ® 1.0%
30
AREA DRAIN PER DETAIL 2, SHEET C-3.6
WITH 4" X 6" REDUCER
RIM = 397.30
IE = 395.00
15
2,500 GALLON GREASE INTERCEPTOR SINGLE
VAULT SYSTEM, UTILITY VAULT 612-GA.
SOUTH RIM = 398.18
IE = 395.85
NORTH RIM = 398.18
6" IE = 395.24 (IN)
31
SANITARY SEWER CLEANOUT
RIM = 399.50
6" IE = 395.04 (OUT)
IE = 393.06
CONTRACTOR TO PROVIDE VENTING AS
SANITARY SEWER CLEANOUT TO BE LOCATED
REQUIRED BY BY UNIFORM PLUMBING CODE.
PER CITY RENTON STANDARD PLAN 406.1
ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF
RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL.
PER SECTION 7 REQUIREMENT FOR PATCHING, OVERLAY, OVERLAY
WIDTHS, 1. TRENCHES (ROAD CROSSINGS) D. IF THE OUTSIDE OF THE
TRENCHING IS WITHIN THREE FEET (31 OF ANY ADJACENT LANE LINE,
THE ENTIRE ADJACENT TRAVELED LANE AFFECTED WILL BE REPAVED.
SEE SHEETS C-3.6 AND
C-3.7 FOR SANITARY SEWER
NOTES AND DETAILS.
S=364304
ENGINEERS CONSTRUCTION RECORD CERTIFICATION
THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH
THE DESIGN INTENT. THIS PLAN, AS MODIFIED HEREIN,
REPRESENTS THE RECORD CONDITIONS OF THE NEW
CONSTRUCTION SHOWN, BASED UPON OUR VISUAL
OBSERVATION, CONTRACTOR INSTALLATION NOTES AND FIELD
MEASUREMENTS BY THE CONTRACTOR. THIS DOCUMENT DOES
NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER
HEREBY CERTIFIES THAT, BASED UPON THE METHODOLOGY
DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT
WITH THE DESIGN INTENT EXCEPT AS NOTED, AND
ACCURATELY REPRESENTS THE EXISTING CONDITIONS, PER
CONTRACTOR PROVIDED RECORD INFORMATION.
PACLAND CERTIFICATION
BY - ----DATE_ 12//9/20/2
0
Z
N
o
Q
C14
of
0
o
0'
N
O0
w
0 ru 0Ld
'I
T--q00 2:
o 0 0
rn 00 0
Z
LnL�
�r a
� �
�--u-
Ln
Co
Ln
Q
00
Ln t+ I
C-3.5
`, - 36o 430�