Loading...
HomeMy WebLinkAboutTRO4103681.26 U zz CO O V) Tn laJ Q a to w EL a w z 8 ry = m o m Q J W M Q 0 m •-I O z PAINT SPECIFICATIONS. ALL ALUMINUM LL I A1RE AND POLE RELATED PARTS SHALL BE FACTORY PRIMED AND POWDER COATED. FINISH COLOR: RAIL 9005TX "JET BLACK' 18-1/4" PRESTIGE SERIES (CYI(LED POST -TOP LUMINAIRE (WATTAGE PER PLANS, 4,000K OCT. 120-277V UNIVERSAL DRIVER, WITH VS3AR 2" CONDUIT ON RIBBED ACRYLIC LENS) BY CYCLONE STATED OTHER\ (OR APPROVED EQUAL). DRIVER PLANS SHALL BE INTEGRAL TO THE FIXTURE. ANCHOR BOLT (4) OVAL SLOTS ACCEPTING 1"x36'x4" GALVANIZED STEEL ANCHOR BOLTS `1 BASE PLATE DETAIL 8 - p5 BARS, EVENLY SPACED CENTER CONDUIT IN FOUNDATION BOLT CIRCLE (DIA PER BASE PLATE DETAIL, THIS SHEET) 14 HOOPS @ 12" FOUNDATION SECTION 2" CONDUIT UNLESS GROUND POLE TO STATED OTHERWISE ON FOUNDATION PLANS z' 3/4' CHAMFER (iYP)� V-6" MIN BELOW GROUND. _ FOR STREET LIGHT 2'-0MIN UNDER STANDARD DECAL PAVEMENT NUMBERING DETAIL, REFER, TO CITY OF EXTEND THE CONDUIT - - - RENTON STD PLAN 121 6" MN BEYOND FOUNDATION OR THE -- CONTROLLED DENSITY BACKFILL - _ — v 14'-0" FLUTED SHAPE, 5" DIAMETER, q4 HOOPS @ 12" STRAIGHT ALUMINUM POLE o (PD15-14-BO46-RAL9005T%-TN43) 8 - ,y5 BARS, zo BY CYCLONE (OR APPROVED EQUAL) EVENLY SPACED 2 1/2" CLR 0 3" MIN. BOLT PROJECTION INSTALL GROUT. PROVIDE 1/2° CIA DRAIN I 24 .� TUBE THROUGH GROUT, FOUNDATION DETAIL 7/B" PIA HOLE 1/4" STEEL PLATE 2 x5" HANDHOLE BOLT CIRCLE (DIA PER BASE PLATE DECORATIVE ALUMINUM CLAMS4ELL �j DETAIL, THIS SHEET) BASE COVER 8046 BY CYCLONE (OR APPROVED EQUAL) POLE BASE DETAIL ANCHOR BOLT TEMPLATE DETAIL SEE POLE BASE TOP OF FOUNDATION DETAIL, THIS SHEET ANCHOR BOLT, 4 TOTAL, 3/4' DIA (TYP) 16" DIAMETER BASE COVER 3/4' HEX NUTS, STEEL (6 REO'D PER ANCHOR BOLT), FLAT WASHERS (6 REO'D PER ANCHOR BOLT) �- FOR FOUNDATION DETAILS, SEE THIS SHEET ANCHOR BOLT ASSEMBLY DETAIL POLE ELEVATION FOUNDATION DETAILS STD. PLAN - 116.1 O PUBLIC WORKS NEIGHBORHOOD STREET PROVED - DEPARTMENT PEDESTRIAN LUMINAIRE FIXTURE AND POLE DETAILS y— *E., 2" BY 3/4" REDUCING WASHER 3/4" ROMEX CONNECTOR WITH LOCKNUT 3/4" SINGLE OR DOUBLE MAST ARM AS aGnlnacn `-FOR DOUBLE MAST ARM, INSTALL 2ND CABLE BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES ARE ON SAME CIRCUIT MAST ARM WIRING DETAIL NOTE: USE #10 OR #12 AWG JACKETED CABLE 1 Y O PUBLIC WORKS STRAIN RELIEF DETAIL STD' PLAN - 118 PROV D: DEPARTMENT '! DA,E POLE 4'-0" (LUMINAIRE ARM LENGTH) 2" TANGENT 7"DIAHOLE 5' R I fi 0 (LUMINAIRE ARM LENGTH) 16' R 22" I 4" OD HOLE 8'-0"------------��� (LUMINAIRE: ARM LENGTH) I 30' R 30" ' 4" OD HOLE I - (LUMINAIRE ARM LENGTH) 45' R 38" __— 4" OD HOLE (LUM!NAIRE ARM LENGTH) 60' R 46" O� -4" OD HOLE- LUMINAIRE ARM DETAILS PAINT SPECIFICATIONS: ALL ALUMINUM LUMINAIRE AND POLE RELATED PARTS SHALL BE FACTORY PRIMED AND POWDER COATED. FINISH COLOR: RAL 9005TX "JET BLACK" DECORATIVE, L'U»IAINAIRE PO N0TE5 ROUND TUBULAR SECTION (NO TAPER) " ROUND TAPERED POLE SECTION (0.14"/FT) NOMINAL LUMINAIRE HEIGHT (LUMINAIRE HEIGHT + SHROUD) SECURE TOP BANNER BRACKET VMTH—­_ THROUGH BOLTS .AND SHIM TO LEVEL PER MANUFACTURER'S INSTRUCTIONS. SECURE BOTTOM BANNER BRACKET WITH ADJUSTABLE STAINLESS STEEL BANDS AND SHIM TO LEVEL PER MANUFACTURER'S INSTRUCTIONS as ROUND POLE CAP LUMINAIRE ARM VGTH PER PLANS (4) OVAL SLOTS ACCEPTING I"x48'x4" ( ALUMINIUM SHROUD (BY MANUFACTURER) GALVANIZED STEEL ANCHOR BOLTS DOMES 55 SERIES LED LUMINAIRE (WATTAGE PER PLANS, 4,000K OCT. 120-277V UNIVERSAL DRIVER, WITH FLAT GLASS LENS) BY LUMEC (OR APPROVED EQUAL). DRIVER SHALL %� ���\ 1� �� �0-� BASE_ PLATE DETAIL BE INTEGRAL TO THE FIXTURE. FOR MOUNTING ARM DETAILS SEE STD n. PLAN 004. 36' 8 - #7 BARS, EVENLY SPACED 2" CONDUIT UNLESS STATED OTHERWISE ON PLANS / CENTER CONDUIT IN FOUNDATION (2) BANNER BRACKETS WITH PRESSURE RELEASE SPRINGS 14'-15" DIA BOLT WITH PROTECTIVE RUBBER ANCHOR BOLT CIRCLE COATING q4 HOOPS @ 12' o' LEVEL FOUNDATION SECTION ,- OPTIONAL 2" CONDUIT UNLESS GROUND POLE TO STATED OTHERWISE ON FOUNDATION BANNER TO BE PLANS PROVIDED AND INSTALLED BY OTHERS 3/4" CHAMFER (TYP) -`; 1'-6" MIN BELOW GROUND DOMUS SMALL SERIES LED LUMINAIRE (WATTAGE PER PLANS. 4,000K COT, 12D-277V UNIVERSAL DRIVER, WITH FLAT 3'-0" CLASS LENS) BY LUMEC (OR 4'- .p APPROVED EQUAL). DRIVER SHALT. BE INTEGRAL TO THE FIXTURE. LUMINAIRE ARM FOR MOUNTING ARM DETAILS SEE L STD PLAN 117.3. 18"-21 FOR STREET LIGHT c> STANDARD DECAL NUMBERING DETAIL, w m REFER TO CITY OF RENTON STD PLAN z i 121. � a � a 10" BASE DIAMETER„ = 40-0" LONG s a z (CONTINUOUS), SMOOTH o N 0 ROUND TAPERED z (0.14"/FT) ALUMINUM < z PCLE 0 `m REINFORCED HANDHOLE o 0 WITH COVER G o INSTALL ANCHOR m o 1 -_ BOLT COVERS (PROVIDED BY POLE `oI MANUFACTURER) 2'-0- UNDER v PAVEMENT 1 ENT EXTEND THE CONDUIT - 6" MIN BEYOND FOUNDATION OR THE 0' LEVEL CONTROLLED DENSITY BACKFILL o #4 HOOPS @ 12" -- a _ 8 - g7 BARS, c zo ? z EVENLY SPACED 02 1/2" CLR o z 0 .o I 18D' 0, It �a 2I0 " I _ 36" -I FOUNDATION DETAIL. • DECOP,AT!VE ROADWAY LUMINAIRES ARE MOUNTED AT 0' • DECORATIVE PEDESTRIAN LUMINAIRES 1-1/8" DIA HOLE (TYP) ARE MOUNTED AT 180' HANDHO_ES \� • ARE MOUNTED AT 180' 3/8" STEEL PLATE • BANNER SUPPORT BRACKETS ARE MOUNTED AT 0' BOLT CIRCLE (DIA ORIENTATION LOCATION SIZE TO LUMINAIRE BASE PLATE DIMENSION) ANCHOR BOLT TEMPLATE DETAIL SIDEWALK OR TOP OF FOUNDATION 'LAF47ER STRIP ANCHOR BOLT, 4 TOTAL, 1" DIA (TYP) ROADWAY �-INSTALL GROUT, I" HEX NUTS, STEEL (6 REO'D PROVIDE 1/2" DIA PER ANCHOR BOLT), FOR FOUNDATION DETAILS, SEE THIS SHEET DRAM TUBE THROUGH FLAT WASHERS (6 REO'D PER GROUT ANCHOR BOLT) ANCHOR BOLT ASSEMBLY, DETAIL, POLE ELEVATION FOUNDATION DETAILS Gti, O ARTERIAL STREET STD. PLAN - 117.1 +r' * PUBLIC WORKS DEPARTMENT DECORATIVE ROADWAY LUMINAIRE POLE APPROVED v O DETAILS6,1 DATE LUMINAIRE LUMINAIRE BUSHING BETWEEN LUMINAIRE ARM AND PIPE CONNECTION FOR THE LUMINAIRE CONDUCTORS SHALL. BE PROVIDED BY MANUFAr TURER ROUND CAP (0-5" MAX HEIGHT) 4" 00 PIPE CLAMP -ON TO LUMINAIRE TENON WITH PLUMBIZER OR LEVELING DEVICE TO SECURE AND LEVEL. LUMINAIRE DECORATIVE PEDESTRIAN LUMINAIRE ROUND CAP ALUMINUM SHROUD (BY MANUFACTURER)_ MANUFACTURER SHALL WELD SHROUD - ALL THE WAY BUSHING BETWEEN LUMINAIRE ARM AROUND - AND PIPE CONNECTION FOR THE LUMINAIRE CONDUCTORS SHALL BE PROVIDED BY MANUFACTURER LUMINAIRE ARM- \ a \ CLAMP -are TO LUMINAIRE LUMINAIRE CONDUCTORS i> �J DECORATIVE -ROADWAY LUMINAIRE LUMINAIRE ARM MOUNTING PUBLIC WORKS I LUMINAIRE ARM AND MOUNTING DEPARTMENT BRACKET DETAILS STD. PLAN - 117.3 PAINT SPECIFICATIONS' ALL ALUMINUM LUMINAIRE AND POLE RELATED PARTS SHALL BE FACTORY PRIMED AND POWDER COATED- FlNISN COLOR: RAL 9005TX "JET BLACK" DECCRATIV LUMIIJAR POLE NOBS ROUND TUBULAR SECTION (NO TAPER) ROUND TAPERED POLE SECTION (0.14"/FT) ROUND POLE CAP (4) OVAL SLOTS ACCEPTING 1"x36"0" • DECORATIVE PEDESTRIAN LUMINAIRES ARE MOUNTED GALVANIZED STEEL 9i AT 180' (UNLESS OTHERWISE NOTED ON PLANS) ANCHOR BOLTS 980' -p• • HANDHOLES ARE MOUNTED AT 180' PLANT • SUPPORT BRACKETS ARE MOUNTED AT 0' (UNLESS ,� ®L�-- 270' OTHERWSE NOTED ON PLANS) Q ��� 1 w a BASE PLATE DETAIL 30" 8 - k5 BARS, ORIENTATION LOCATION 2" CONDUIT UNLESS EVENLY SPACED STATED OTHERWISE ON PLAIDS CENTER CONDUIT IN FOUNDATION 10'-11" DIA BOLT CIRCLE ANCHOR BOLT A4 HOOPS Q 12" FOUNDATION SECTION 2" CONDUIT UNLESS GROUND POLE TO • STATED OTHERWISE ON FOUNDATION 4•-0" 'o PLANS i LUMINAIRE ARM g 3/4' CHAMFER (TYP) - V4, wN BELOW GROUND. =V _ 2' 0" MINUNDER t 1 PAVEMENT 15-21' EXTEND THE CONDUIT -- - < T DOMUS SMALL SERIES LED 6" MIN BEYOND a. LUMINAIRE (WATTAGE PER PLANS, FOUNDATION OR THE 4,000K OCT, 120-277V UNIVERSAL CONTROLLED DENSITY a. DRIVER, WITH FLAT GLASS LENS) BACKFILL BY LUMEC (OR APPROVED EOUAL). DRIVER SHALL BE INTEGRAL TO p4 HOOPS @ 12' - zo THE FIXTURE, FOR MOUNTING ARM � DETAILS SEE STD PLAN 117.3 . an 8 - M'5 BARS, -- z FOR SIR[[, -%G EVENLY SPACED 0 DECAL NL __ 'PETFR 2 112" CLR TO CITY CF FF.NTQJ ,TO PLAN 121 7" BASE DIAMETER, 18'-0- LONG m (CONTINUOUS), SMOOTH ROUND FOUNDATION DETAIL TAPERED FIT 14"/FT) ALUMINUM POLE 1-I/8" DIA HOLE (TYP) _ REINFORCED HANHDOLE `MTH COVER I/4" STEEL PLATE BOLT CIRCLE (DIA INSTALL ANCHOR BOLT COVERS SIZE TO LUMINAIRE (PROVIDED BY POLF BASE PLATE MANUFACTURER) DIMENSION) SIDEWALK OR INSTALL GROUT. — PLANTER ANCHOR BOLT TEMPLATE DETAIL PROVIDE 1/2- DIA DRAIN STRIP TUBE THROUGH GROUT :',JN. ATI N ANCHOR BOLT, 4 TOTAL, 1" DIA FOR FOUNDATION DETAILS. (iYP) SEE THIS SHEET F. HEX NUTS, STEEL (6 REO'D PER ANCHOR BOU), FLAT WASHERS (6 REO'0 PER ANCHOR BOLT) ANCHOR BOLT ASSEMBLY DETAIL POLE ELEVATION FOUNDATION DETAILS O ARTERIAL STREET STD. PLAN - 117.2 PUBLIC WORKS ♦�� DECORATIVE PEDESTRIAN LUMINAIRE POLE A PROVED DEPAR'TA4ENT121 ju AV O DETAILS 7DA E 44 INSTALL DECAL NUMBERS VERTICALLY INSTALL IN DRY WEATHER, 50' F OR ABOVE. NUMBERING ----=E-YCAMPLES LETTER SUFFIXED CITY OWNED MOUNTING HEIGHT 10 15 FEET �( + �c F 45' TRAFFIC FLOW PLAN VIEW LETTER PREFIXED PUGET POWER OWNED 1-3/4" TO 2" 2" TO 2-7/8" 2-1/2" TO 3" DECAL: REFLECTORIZED GOTHIC GOLD OR WHITE LEGEND ON BLACK BACKGROUND Y + PUBLIC WORKS STREET LIGHT STANDARD o STD. PLAN - 12 DEPARTMENT DECAL NUMBERING SYSTEM 6 /1 %� �T t0 DATE' CAUTION: LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO POTHOLE AS REQUIRED AND FIELD VERIFY LOCATION OF UTILITIES UNDERG LI I i FL YOU MUST CALL 1-800-424-5555 NOT LESS THAN 72 HOURS BEFORE BEGINNING EXCA VA TION WHERE ANY UNDERGROUND UTILITIES MAY BE LOCATED. FAILURE TO DO SO COULD MEAN BEARING SUBSTANTIAL REPAIR COSTS (UP TO THREE TIMES THE COST OF REPAIRS TO THE SERVICE). RECOMMENDED FOR APPROVAL BY BY BY CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE DATE DATE �(:)N X l ;fE QUA NORTHWEST T17A FF/G EXPER TS ,� 30251 FS F�/STE' 11410 NE 124th St., #590, Kirkland, WA 98034 S/ONAL Phone:425.522.4118 Fax:425.522.4311