Loading...
HomeMy WebLinkAboutWWP2703681.5NE 114 SECTION 10y TOWNSHIP 23 N, RANGE 5 E, W.M. W Q z � U w M O OY ' ^ Qf bi Ln� 1__L W (SEE NOTE 7) LIMITS OF PIPE ZONE BEDDING MATERIAL FOR SANITARY SEWER PIPE O.D. OF PIPE (SEE NOTE 5) FOUNDATION LEVEL -� BEDDING FOR SANITARY SEWER PIPE NOTES: 1. PROVIDE UNIFORM SUPPORT UNDER BARREL. 2. HAND TAMP UNDER HAUNCHES. 3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY OVER PIPE. HAND TAMP ONLY. 4. PIPE INSTALLATION SHALL BE PER SECTION 7-08 OF THE STANDARD SPECIFICATIONS. 5. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS" AS SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD SPECIFICATIONS OR PEA GRAVEL. 6. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE FLOW LINE IS MAINTAINED. 7. TRENCH WIDTH SHALL BE PER SECTION 2-09.4 OF THE STANDARD SPECIFICATIONS. STD. PLAN - 405 PUBLIC WORKS PIPE BEDDING ` `•` + DEPARTMENT i FOR SANITARY SEWERS 1�1\ Cod OCTOBER 2012 r � Call 2 Working Days Before You Dig 1-800-424-5555 Utilities Underground Location Center (ID,MT,ND,OR,WA) 32162 R�SCER IONAL 7' IB' I NOT TO SCALE PIPER'S BLUFF MANHOLE FRAME AND COVER SEE STD. PLAN 401 ADJUSTMENT RINGS (2" MIN.) SEE NOTE 6 MORTAR JOINT(S) (3/8" MIN.) SEE NOTE 5 CONE (ECCENTRIC) RUBBER GASKETED JOINTS IN ACCORDANCE WITH ASTM C-443 STEPS - POLYPROPYLENE STEPS SHALL BE INCLUDED CONCRETE RISER BY PIPE INC., OR APPROVED EQUAL. LADDER -POLYPROPYLENE SHALL BE ATTACHED TO MANHOLE MAX. PIPE SIZE - 'E' CONCRETE SHELF PRECAST BASE SECTION OR CAST IN SHELF. 'A' 'B' 'C' 'D' 'E' 48" MH 48' 6" MIN. 5"MIN 24" MIN. 21" I.D. 54 MH 54 8" MIN. 5.5" MIN. 1 24" MIN. 24" I.D. 60" MH 60' 8" MIN. 6" MIN. 1 42" MIN, 30" I.D. NOTES: 1. STEPS TO BE POLYPROPYLENE SAFETY STEPS. 2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED. 3. CASTING SHALL BE PER STD. PLAN 401. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. 5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED. 6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOMPLISHED WITH A COMBINATION OF ADJUSTMENT RINGS, BRICKS AND MORTAR ONLY. BRICKS SHALL BE STAGGERED TO CREATE A RUNNING BOND OR 1/2 BOND. THE USE OF SHIMS IS PROHIBITED. 7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDI"G CHANNELING, COATED (SEALED) WITH A HIGH SOLIDS URETHANE COATING; WASSER MC-AROSHIELD OR APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE. 8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE WITH ASTM C-443. 9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE. 10. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR, KOR-N-SEAL BOOTS OR APPROVED EQUAL. 11. IN UNIMPROVED AREAS, MANHOLES SHALL EXTEND A MINIMUM OF 6" AND A MAXIMUM OF 12" ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2' DIAMETER CONCRETE RINGS POURED AT GRADE. IN PAVED AREAS, COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. Oti�y p� PUBLIC WORKS STD. PLAN - 400.1 +(�n� � DEPARTMENT STAI+IDARD SANITARY MAMANHOLEf SEPTEMBER 2011 6" BUILDING SEWER PIPE WITH 6" SIDE OUTLET 6" SIDE SEWER AND BUILDING SEWER 1:3:5 MIX CONCRETE BLOCKING �ROPERTY LIIJE 3'-0" oI1 FUTURE BUILDING SEWER \ w z 6"X6' X6" WYE `2 x 4" STUD MARKING POST PAINTED SURFACE CLEANOUT WITH WHITE WITH THE WORD "SEINER" STENCILED cr CAST IRON RING & COVER IN 3" HIGH BLACK LETTERS AND #6 WIRE o(EAST JORDAN IRON WORKS WRAPPED AROUND THE STUD AND a 2975 OR APPROVED EQUAL; EXTENDED TO THE TOP OF THE STUD. SPECIFY "SEWER" ON LID, SEE STD. PLAN 403,1 FOR INSTALLATION) ACCEPTABLE PROCEDURES FOR SIDE SEWER CONNECTIONS TO MAIN LINES ARE AS FOLLOWS: A. VITRIFIED CLAY MAIN - CUT IN A NEW TEE USING FLEXIBLE COUPLINGS (FERNCO OR APPROVED EQUAL). B. CONCRETE MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL), C. PVC MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) OR CUT IN A. NEW TEE USING RIGID COUPLINGS, D. DUCTILE IRON MAIN - CORE -DRILLED WITH A ROMAC SADDLE (OR APPROVED EQUAL) E. MANHOLE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE AT MANUFACTURED KNOCK -OUTS OR THE STRUCTURE SHALL BE CORE -DRILLED, r60" ALLOWABLE MAX. FOR CAST IRON PIPE OR DUCTILE IRON PIPE. 6" SIDE OUTLET TEE I SEWER 6" MIN. MAIN SE CONCRETE BLOCKING ANGLE OF TEE AT MAIN OVER 25 ELEVATION NOTE: UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER. PNG 06 2 GON 2% MIN SLOPE HORIZONTAL R MAIN TYPICAL SIDE SEWER ELEVATION Y STD. PLAN - 406.1 STANDARD SIDE SEWER 0 a PUBLIC WORKS DEPARTMENT I INSTALLATION I- - ��NSOS (SEWER MAIN TO PROPERTY LIT1E) � SEPTE?fBER 2011 SEAL WITH AR 4000 OR APPROVED EQUAL AND DRY SAND AFTER PATCHING I PATCHED AREA PLAN NTS SECTION A -A NOTES: A 2" ASPHALT CLASS "B" OR AS APPROVED BY THE ENGINEER. CONCRETE REMOVE PAVEMENT AND BASE MATERIALS FOR A DISTANCE WHICH IS EQUAL TO THE DIAMETER OF THE FRAME PLUS TWO FEET. ADJUST CASTING FRAME TO PAVEMENT SURFACE USING RISER RINGS OR CONCRETE BLOCKS PER STD. PLAN 400.1. REPLACE ALL BUT TOP 2" OF EXCAVATED MATERIAL WITH CLASS 3000 CONCRETE (3/4). FINISH PAVEMENT SURFACE WITH 2" OF ASPHALT CLASS "B" OR AS APPROVED BY THE ENGINEER. y �ti2 °.n EE PUBLIC WORTYPICAL UTILITY COVER STD. PLAN - 400.4 KS I DEPARTMENT ADJUSTMENT FOR PAVEMENT OR OVERLAY DECEMBER 2010 Grout adjusting rings inside, outside and between. Grout under casting. X c a I o (1)c E E c'' rn E E - Er �. Co N m Mortar/N I � 5 I C Copolymer Polypropylene -Co Plastic Steps & Ladder. I per the Standard Detail. to 2 Locate as shown on plan view below. I P id t t k k- t Manhole Frame and Cover per the Standard Detail. Locate as shown on plan. 11-III- Minimum requirement for adjustment shall be (2) - 4" rings. Eccentric cone. 1' section below cone is required. -Confined 0-ring rubber gasket joints and butyl sealant strips (typ.) rove grou a noc ou , s Provide sand collar for PVC I Pipe' 1 a Poured in place Class 4000 cement concrete base. , TTI- TT Kor-n-Seal boot by NPC, Inc., or approved equal. c N E a , M slope 3/8"/ft +' I � flow -11- -II^III 11 Pea gravel bedding per ELEVATION the Specifications. Foundation gravel per the Specifications, if required. Notes: 1. Marker posts may be required in easements. l flow 1. ' I I I /I I � Manhole steps. Frame and cover. P LA N A_ L, ANHQL.E NOT TO SCALE Detail Approvals NORTHS"ORE UTILITY DISTRICT ;) Engineer GSM I�� Manager DPK STANDARD SEWER DETAILS MguM 2011 s2(3A0DLEAIH).DWG 1 REVIEW COMMENTS 11 04.03.13 WUC 5.22.13 LRJ SURVEYED: scA`E` VERTICAL: NAVD 1988 D.R. STRONG sJs AS NOTED HORIZONTAL:NAD 19e3/1991 CONSUL 7ING ENGINEERS DESIGNE NAK DRAWN:[DR ENGINEERS PLANNERS SURVEYORS WIC 'ou, 10604 NE 38th PL, #101 KIRKLAND, WA 98033 ONE INCH ��M O 425.827.3063 F 425.827,2423 CHECKED: A7 FULL SCALE ^� n IF NOT ONE INCH www.drstrong.com ! VI 0 , REVISION B �/ DATE ^ P P f \ APPROVED: SCALE ACCORDINGLY LRJ BDLTHDLES - 3 PLCS EQUALLY SPACED 120' APART ON 23 1/16' (586mm) DIA B,C, (SEE DETAIL) 8� RENTON O SEWER ti NAM IN USA COVER & FRAME PLAN VIEW 15' DIA, 1635Mr1] 1" 3/4' r 125 nr 7 [19rnm] 8 3/4' 2 i/2" 1222mml 164riml TYP COVER SECTION VIEW 26 1/2' DIA C673mml 25 1/4' DIA m r ] 1 1/16" 1/4' (6nr1) DIA r 127rtr,] NEOPRENE GASKET jl -_- 6' [lsl r,rn] 5/8' 23 3/8' DIA CL OPEN 1 116mml 1594mml 27 5/16' DIA _J 1694mml - 34 1/8' DIA COVER BOTTOM VIEW (3) BLT SOC, (ALLEN HEAD) 5/8'-11 X 1.5 SS RUBBER WASHER EON BOLTING DETAIL 1/4' -' ~1 1/16' I6mm, � [27MM] 1 I I3mm] IR3mr)] GASKET GROOVE DETAIL I867mm' NOTES: FRAME SECTION VIEW I. ALL COVERS SHALL BE LOCKING LID PER EAST JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL. 2. USE FRAME AND COVER FOR STORM (SPECIFY "DRAIN" ON COVER), SANITARY (SPECIFY "SEWER"), OR WATER (SPECIFY "WATER"). PI STD. PLAN - 401 PUBLIC WORKS DEPARTMENT MANHOLE FRAME AND COVER DECEMBER 2008 - CITY OF RENTON Planning/Building/Public Works Dept. 368105 DRAWINGS NOT APPROVED FOR CONSTRUCTION UNLESS STAMPED OR SIGNED APPROVED BY THE REVIEWING AGENCY RECOMMENDED FOR APPROVAL R Y - BY BY 06-28-12 FIELDBOOK: PIPERS BLUFF PAGE: SANITARY SEWER DETAILS DRAWING " SHEET: OF: C18 18 c�11�I Al-NNNNA� b x 0 tz 1 o �J C71 a� � � r 1