HomeMy WebLinkAboutTRO4103699.110+00
-- I
LEGEND
EXISTING TYPE I JUNCTION BOX
m
TYPE 1 JUNCTION BOX
EXISTING TYPE 2 JUNCTION BOX
EXISTING TYPE 7 JUNCTION BOX
SIGNAL CABINET
SERVICE CABINET
EXISTING STREET LIGHT STANDARD
�--
STREET LIGHT STANDARD
SIGNAL POLE WITH STREET LIGHT
QWIRE
NOTE
OCONSTRUCTION
NOTE
WOOD POWER POLE (PSE)
PORTION OF THE S W 1/4 OF SEC. 23, TWN. 23N.., RNG 5 E. WM
KING COUNTY, WASHINGTON
SR 169 (MAPLE VALLEY HIGHWAY)
11 +00 12+00 13+00 14+00 15+00 16+00_ 17+00 _
1 3 #2 1 #3 3 1 #4
--------- ----------------- ---------------------------- ----------------- ---- ---
t 5' SIDEWALK \,� _ 5' SIDEWALK
_ _
4
�D
2 4
1 2 2
EXISTING SERVICE TYPE D
5 �
I
I
I
e
1 3
CONSTRUCTION NOTES
` U� 11
OFURNISH
AND INSTALL ALUMINUM LIGHTING STANDARD WITH 8' DAVIT STYLE
ARM, 40'
1
11
MOUNTING HEIGHT, 140 WATT LED, R3 DISTRIBUTION, 240 VAC COBRA HEAD
LUMINAIRE
WITH LAMP. INSTALL CONCRETE FOUNDATION WITH TOP PAD LEVEL WITH SIDEWALK. SEE
`
CITY OF RENTON DETAILS, WSDOT STANDARD PLANS J-28.70, J-28.10, AND
J-28.30.
1
SEE CITY OF RENTON DETAILS IN PLANS.
OFURNISH
AND INSTALL ALUMINUM LIGHTING STANDARD WITH 12' DAVIT STYLE
ARM, 35'
N 1
MOUNTING HEIGHT, 140 WATT LED, R3 DISTRIBUTION, 240 VAC COBRA HEAD
LUMINAIRE
WITH LAMP INSTALL CONCRETE FOUNDATION WITH TOP PAD LEVEL WITH SIDEWALK SEE
1
CITY OF RENTON DETAILS, WSDOT STANDARD PLANS J-28.70, J-28.10, AND J-28.30. 1
I
SEE CITY OF RENTON DETAILS IN PLANS.
OFURNISH TRENCH BACK FILL AND INSTALL PVC SCHEDULE 80 CONDUIT WITH MINIMUM 24»
COVER AS SHOWN ON WIRING/CONDUIT SCHEDULE ON THE PLANS.
OFURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON THE PLANS. SEE WSDOT
STANDARD PLANS J-40.10-03.
O5 SPLICE AND MAKE CONNECTION TO EXISTING SYSTEM.
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE WSDOT/APWA STANDARD SPECIFICATIONS FOR
ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION (STANDARD SPECIFICATION AS MODIFIED BY THE CITY
OF RENTON SPECIAL PROVISIONS; NATIONAL ELECTRICAL CODE (NEC); CITY OF RENTON
CONSTRUCTION STANDARDS; WSDOT STANDARD PLANS AND THESE PLANS.
2. PRIOR TO ANY CONSTRUCTION ACTIVITY, THE CONTRACTOR SHALL ATTEND A PRE —CONSTRUCTION
CONFERENCE WHICH WILL BE SET UP AND RUN BY THE CITY OF RENTON DEVELOPMENT SERVICES
DIVISION.
3. THE CONTRACTOR MUST SUBMIT AND RECEIVE APPROVAL FOR: TRAFFIC CONTROL PLANS (TCP), AND
TEMPORARY EROSION/SEDIMENTATION CONTROL PLANS (TESCP) PRIOR TO START OF ANY
CONSTRUCTION ACTIVITY ON —SITE OR OFF —SITE.
4. APPROVED STREET LIGHT PLANS SHALL BE ON THE JOB SITE WHENEVER STREET LIGHT
CONSTRUCTION IS IN PROGRESS.
5. ALL JUNCTION BOXES SHALL BE PER WSDOT STANDARD PLAN J-40.10-02 AND TOP OF LID
MARKED AS LIGHTING BY THE LEGEND "LIGHTING" OR "SL».
6. ALL CONDUIT SHALL BE SCHEDULE 80 PVC.
7. ALL WIRE SHALL BE U.S.E. COPPER SIZED PER WIRING/CONDUIT SCHEDULE.
8. ALL LUMINAIRE POLES SHALL BE VALMONT OR APPROVED EQUAL. ALL LUMINAIRES SHALL BE AEL
OR APPROVED EQUAL.
9. ALL NEW' POLES SHALL BE LABELED WITH STREET LIGHT STANDARD DETAIL. NUMBER TO BE
SUPPLIED BY CITY OF RENTON. SEE CITY OF RENTON DETAILS IN PLANS.
Bridge Engr.
Supervisor
Designed By
Checked By
Detailed By
Bridge Projects Engr.
Preliminary Plan By
Architect/Specialist:
BREAKER SCHEDULE
SERVICE &
CIRCUITS
MAIN
BREAKER
AMPS
BRANCH
BREAKER
AMPS
CONTACTOR
AMPS
VOLTS
Service
200
NA
240
SIGNAL
50
NA
120
GFCI
20
NA
120
CIRCUIT A
20
30
240
CIRCUIT B
20
30
240
CIRCUIT C
20
CIRCUIT D
20
CIRCUIT E
20
STRIP HEATER
15
NA
120
PHOTOCELL
15
NA
120
PANEL SCHEDULE
NO.
LOCATION: SR 169/152 AVE S.E.
120/240 VOLTS 1 PHASE 3 WIRE
SERVING: STREET LIGHTS, TRAFFIC SIGNAL
200 AMP with MAIN BREAKER
CKT
NO.
LOAD DESCRIPTION
KVA
TRIP TRIP
AMPS AMPS
2012 20
KVA
LOAD DESCRIPTION
CKT
NO.
Al
STREET LIGHTS 1, 20, 22, 26, 28
1.68
3.36
STREET LIGHTS 2,3,4,6,7,8,9,10,21,24
B2
20 71 8 20
20 910 50
6.00
TRAFFIC SIGNAL
10
11 ^12
13
GFCI DUPLEX RECEPTACLE
0.24
20 13, _,14
15
STRIP HEATER
0.18
15 15� ^1s
17
PHOTOCELL
0.18
15 17, �
19,-, _,20
REMARKS: ADDED LUMINAIRES 1 & 2 ON 7-99
CONNECTED LOAD: 11.64 KVA 48.5 AMPS
DEMAND LOAD: 125% KVA 60.6 AMPS
LUMINAIRE SCHEDULE
LUMINAIRE
CITY
POLE
POLE
POLE
POLE
MOUNT
MAST ARM
CURB/EDGE LINE
WATTAGE
LUMINAIRE TYPE
TYPE
POLE TYPE
STANDARD
COMMENTS
NO.
STREET
ID #
STATION
OFFSET
HEIGHT
LENGTH
OVER HANG
VOLTAGE
TYPE
DISTRIBUTION
#
1
152nd Ave SE
(E. SIDE)
11+27
222' RT
35'
12'
4.5'
240 VAC
94 W
94W — AT82 40BLEDE70 MVOLT R3 NL
R3
280645807T4C
LIGHTING CIRCUIT B LEG 4
NEW
2
SR 169
(S. SIDE)
15+02
44' RT
40'
8'
0.0'
240 VAC
138 W
138W — AT82 60BLEDE70 MVOLT R3 NIL
R3
330645808T4A
LIGHTING CIRCUIT A
NEW
3
SR 169
(S. SIDE)
16+00
44' RT
40'
8'
0.0'
240 VAC
138 W
138W — ATB2 60BLEDE70 MVOLT R3 NL
R3
330645808T4A
LIGHTING CIRCUIT A
NEW
4
SR 169
(S. SIDE)
17+41
44' RT
40'
8'
0.0'
240 VAC
138 W
138W — ATB2 60BLEDE70 MVOLT R3 NL
R3
330645808T4A
LIGHTING CIRCUIT A
NEW
WIRE / CONDUIT SCHEDULE
RUN
CONDUIT
NO.
SIZE
CONDUCTORS
COMMENTS
1
A,
2» PVC
2
2—#8
ILLUMINATION CIRCUIT A
NEW
1—#8
GROUND CIRCUIT A
2
»
2 PVC
2—#10
ILLUMINATION CIRCUIT A
NEW
1—#8
GROUND CIRCUIT A
3A
2' PVC
2—#8
ILLUN41NATION CIRCUIT B
LEG 4
NEW
1—#8
GROUND CIRCUIT B LEG
4
4
»
2 PVC
2—#10
ILLUMINATION CIRCUIT B
—4
LEG 4
NEW
1—#8
GROUND CIRCUIT B LEG
T=16990
U 150005C-5
CITY OF RENTON
Approved by: Z + /v. •&a is - Date: c.4 /�. /.s
Approved by: Date:
Approved by: Date:
Approved by: Date -
MAPLE VALLEY HIGHWAY
R.A- 3/15 p DN TRAFFIC CONSULTANTS G.N. 3115 152ND AVENUE SE INTERSECTION VICINITY
i
R.A. 3/15 ,�„� 8316 - 309th Avenue SE Preston, WA 98050 CEDAR RIVER STATION CITY OF RENTON MARCH 2O15
_ _ �
R.A. 3/15E�
- REVISIONS BY APPR. OFF -SITE LIGHTING
SHT 1 OF 2
:'
z
z
(7)
c
0
M
3
I�
z
z
m
0
W
M
M
0
D
N to
D
�
o
z
1Z