Loading...
HomeMy WebLinkAboutWWP2703712.3N LEGEND: ABBREVIATIONS SYMBOLS AND DESIGNATIONS T Co EXISTING PROPOSED AASHTO AMERICAN ASSOC. OF STATE MBMFR MANUFACTURER O HIGHWAY MH MANHOLE r_� -------- RIGHT OF WAY -- -- — BNSF PREMISES TRANSPORTATION OFFICIALS MIN MINIMUM TITLE AB ANCHOR BOLT MON MONUMENT TITLE DETAIL NUMBER CENTERLINE GRAVITY SEWER AC ASPHALT CONCRETE MUTCD MANUAL ON UNIFORM TRAFFIC -- PROPERTY LINE SANITARY SEWER MANHOLE OR STRUCTURE ACP ASPHALT CONCRETE PAVEMENT CONTROL DEVICES DETAIL ADS POLYETHYLENE PIPE MW MONITORING WELL L2� SCALE-. 1/2" = 1'-0" C-2 � -- - - EASEMENT ///////////, TO BE REMOVED OR ABANDONED ALD ALDER — DRAWING NUMBER WHERE DETAIL APPROX APPROXIMATE N NORTH IS REFERENCED. USE DASH IF CONTOUR ASPHALT CONCRETE PAVEMENT (ACP) - PLAN APWA AMERICAN PUBLIC WORKS NAD NORTH AMERICAN DATUM DETAIL APPEARS ON THE SAME ASSOCIATION NAVD NORTH AMERICAN VERTICAL DATUM SHEET AS SHEET REFERENCED. Mic MONUMENT IN CASE PRE -CAST CONCRETE AVE AVENUE NE NORTHEAST NIC NOT IN CONTRACT BF BLIND FLANGE NO. NUMBER TITLE MON® SURFACE MONUMENT CSBC SECTION, ELEVATION OR BH BORE HOLE NTS NOT TO SCALE TITLE /� BLVD BOULEVARD NW NORTHWEST PROFILE REFERENCE LETTER o PK NAIL BM BENCH MARK SECTION A REBAR & CAP BNSF BURLINGTON NORTHERN SANTA FE OC ON CENTER SCALE: 1/2" - V-0" - _� DASH IF SECTION IS TAKEN ON THE OD OUTSIDE DIAMETER CB CATCH BASIN OH OVERHEAD SAME DRAWING. USE DRAWING SEWER MANHOLE CCW COUNTER CLOCK WISE OP OVERHEAD POWER NUMBER IF SECTION WAS TAKEN CDF CONTROLLED DENSITY FILL OPG OPENING ON A DIFFERENT SHEET. POWER POLE CF CLEARING LIMIT FENCE POWER POLE W/UNDERGROUND CONNECT CHLK CHAIN LINK P POWERCIPP CURED IN PLACE PIPE PE PLAIN END, PROFESSIONAL ENGINEER SECTION LETTER GUY ANCHOR C/L, CL CENTERLINE PG PERFORMANCE GRADE A - CLR CLEAR PSF POUNDS PER SQUARE FOOT C-1 CO CLEANOUT PSI POUNDS PER SQUARE INCH DRAWING NUMBER WHERE DETAIL CALLOUT POWER MANHOLE CONIC CONCRETE PVC POLYVINYL CHLORIDE SECTION IS DRAWN. USE DASH IF CPLG COUPLING PVMT PAVEMENT SECTION APPEARS ON SAME 4/C-1 TELEPHONE MANHOLE CSBC CRUSHED SURFACING BASE COURSE PWR POWER SHEET AS CUT. CSTC CRUSHED SURFACING TOP COURSE DRAWING # GAS VALVE RD ROAD ELEVATION LETTER DETAIL # WATER VALVE D/W DRIVEWAY REINF REINFORCEMENT A D DEPTH, DOUBLE REQ D REQUIRED DBH DIAMETER BREAST HEIGHT RET RETAINING C-1 WATER METER DI DUCTILE IRON ROW, R/W RIGHT OF WAY �— DRAWING NUMBER WHERE ELEVATION IS DIA DIAMETER RRC RED REBAR AND CAP DRAWN. USE DASH IF ELEVATION WATER VAULT LID DIP DUCTILE IRON PIPE RT RIGHT APPEARS ON SAME SHEET AS DIPS DUCTILE IRON PIPE SIZE REFERENCED. FIRE HYDRANT DR DRIVE S SOUTH, SLOPE BLOW -OFF DTREE DECIDUOUS TREE SCH SCHEDULE DWG DRAWING SD STORM DRAIN BORE SITE (W/ FIELD DESCRIPTION) SDMH STORM DRAIN MANHOLE PIPING DESIGNATIONS E EAST, ELECTRICAL SDR STANDARD DIMENSION RATIO EA EACH SE SOUTHEAST MONITORING WELL EW EACH WAY SERV SERVICE EL, ELEV ELEVATION SF SILT FENCE PIPING IS IDENTIFIED BY ITS SIZE FOLLOWED BY PIPING SYSTEM AS FOLLOWS: GUARD POST EP EDGE OF PAVEMENT SSFM SANITARY SEWER FORCE MAIN EX EXISTING SMH SEWER MANHOLE DESIGNATES NEW PIPING: SIGN SS SANITARY SEWER SHRUB FF FINSHED FLOOR SST STAINLESS STEEL 8" SS FIG FINISH GRADE ST STREET PVC DECIDUOUS TREE, DIA (# OF TRUNKS) FT,' FEET STA STATION STD STANDARD DESIGNATES EXISTING PIPING: PAINTED POWER G GAS STL STEEL w M GALV GALVANIZED SW SOUTHWEST GRAY GRAVEL �� EX 8" CONC SS PAINTED TELEPHONE GV GATE VALVE T TELEPHONE o T&B TOP AND BOTTOM PAINTED FIBER OPTIC HDPE HIGH DENSITY POLYETHYLENE TBM TEMPORARY BENCHMARK FOR NEW PIPING MATERIAL, FITTINGS, AND VALVES, SEE SPECIFICATIONS. A HMA HOT MIX ASPHALT TELJB TELEPHONE JUNCTION BOX GENERAL PIPING MATERIAL MAY BE NOTED. PAINTED TV HORIZ HORIZONTAL TELR TELEPHONE RISER PAINTED WATER HT HUB AND TACK TV TELEVISION (CABLE) PIPING SYSTEM DESIGNATIONS FOR EXISTING PIPING INDICATE TYPE OF HYD HYDRANT TVJB TELEVISION (CABLE) JUNCTION BOX SERVICE AND TYPE OF MATERIAL IF KNOWN. CONTRACTOR SHALL VERIFY ALL PAINTED GAS TVR TELEVISION (CABLE) RISER EXIST PIPE MATERIAL AND NOT RELY ON THIS DESIGNATION PRIOR TO ID INSIDE DIAMETER TYP TYPICAL CONSTRUCTION. SEWER IE INVERT ELEVATION IN, " INCH UGP UNDERGROUND POWER FENCE IPS IRON PIPE SIZE UNO UNLESS NOTED OTHERWISE JB JUNCTION BOX VCP VITRIFIED CLAY PIPE RAISED -BUTTON SOLID STRIPE VERT VERTICAL DRAWING REFERENCE L LENGTH RAISED -BUTTON SKIP STRIPE LF LINEAR FEET W/ WITH EDGE OF PAVEMENT LN LANE W WATER, WEST G GENERAL LT LEFT WL WATER LEVEL C CIVIL WM WATER METER �j CONCRETE MAX MAXIMUM WSDOT WASHINGTON STATE DEPARTMENT � MB MAIL BOX OF TRANSPORTATION GRAVEL MDD MAXIMUM DRY DENSITY WS WATER SERVICE Q� �Cn Call 48 Hours 09z z Before You Dig S=03 712 1-800-424-5555 z U �s zr <r S UNDERGROUND SERVICE o w<I 1 of wash jl of w"asr1 BHC Consultants, LLC �� /�G �4, �ti.�� DATE SURVEYED: SCALE w o w � KPG VERTICAL NAVD 1988 83/1 C T1, O CENTRAL RENTON SEWER INTERCEPTOR MAY 2015 1601 Fifth Avenue, Suite 500 ��� N HORIZONTAL: NA.D 1983/1991 �� DESIGNED: �� . Seattle, Washington 98101 -- C' T. WHITEHOUSE, P.E. R E N T� N RELINE & UPSIZE PROJECT EIELD6°°K. z ..11 Z PAGE: ��� 206.505.3400 49545 �770 DRAWN I DATU M P. SIti3Oti DRAWING No: w 206.505.3406 (fax) A� �� �° �o ONE INCH Y o� �rST�� w�' ,�� STE �� ss Eo FOR BIB T�v o5/2o JSK CHECKED: G AT FULL SCALE Public works Dept. LEGEND, ABBREVIATIONS, SYMBOLS &DESIGNATIONS (�-3 SEATTLE TACOMA www.bhcconsultants.com N��. s ON cs J. KRESHEI, .E. SCALE ONE N R� CH s'% �' sIo dill 15 �/�i5 NO. REVISION BY DATE APPR APPROVED: s+EET of � R. BORN, P.E. 7 jj-1 G z -• D DZ mm CG 7 ` �= C 000 Cil En � C3 Nz m Z m m m 0 D D m 0 0 o° 00 ' D �Z zm c� m= 'm° m `" fu N z Z m 0 O m D Z C co m �m rn7 xy o C) > I o� z o zmz b� w Cm c z N z DO D o p o m CD D