Loading...
HomeMy WebLinkAboutWWP2703712.4N CL SI TYP - REMOVE EX 72" DIA BRICK MH AND REPLACE WITH NEW 84" DIA SMH 1968, PER DETAIL 1/C-2 PK 2 s V A \ \ STA 1+04 /\o DEL RY" OFFSET 1' RT x N 181163.90 01� \ o- SEE NOTE 5 E 1303744.48 \ c c T EL 41.09 / \ \ \ p \ \ STA 1 +00 AB-2 `TYP 5 9 N 181167.6 1 E 1303802.05'1(P p 0 10 20 \ \ ° . p l SEE DETAIL 1/C-2 24" SS / \ ° �� PVC OMNIScale in Feet TO AB-1 AS REQUIREQ 1+50 ° REMOVE EX 4 / GB-15 \ ° \ \ .. \ 5 8 TYP \ \ \ \ \ 12 VCP SS 2' N U TYP c i c _ — EXr18"PVC —� 7 EX 60" DIA • • / SMH 4692 SADDLE TYPE / 9' C, STA 2+27± ° MIN a / I GB-14 Z \ _ w ° NI112 81151.07 ° TYP 3 E 1303866.48 z/ 5 GP EL 53.98 W Q EX 12" VCP SS AN s T T pU.CT . SMH PLUGGED _� ``...__..._—...__...—_..._ — w---- 'TVGP GP w --� / AND ABANDONED r BELOW GRADE Eth EX 15" CONIC SS : BNSF PREMISES: WORK SHALL COMPLY WITH THE PROJECT'S BNSF TEMPORARY OCCUPANCY PERMIT AND THE REQUIREMENTS NOTED ON THESE PLANS AND IN THE SPECIFICATIONS, SEE NOTE 4. 65 CONSTRUCTION NOTES: 10 REMOVE AND REPLACE PAVEMENT PER RENTON STD PLANS 110 AND 110.1. EXISTING PAVEMENT THICKNESS IS ANTICIPATED TO BE 6" OF ASPHALT OVER 4" OF 60 CONCRETE. NEW HMA SHALL MATCH TOTAL THICKNESS OF EXISTING PAVEMENT (-10"), CONCRETE BASE SHALL NOT BE REPLACED. 20 REMOVE AND REPLACE SIDEWALK, CURB AND GUTTER, 55 AND PAVEMENT PER RENTON STD PLANS 102 AND 103, AND PER WSDOT STD PLAN F-10.12-02. 1 O3 REMOVE EXISTING 6' CHAIN LINK FENCE AS NECESSARY AND REINSTALL/REPLACE FENCE TO MATCH EXISTING. 50 (a� 40 REMOVE AND REINSTALL DISTURBED RAILROAD TIES -d-I BETWEEN BARK AND GRAVEL LOT TO MATCH EXISTING. o NI 2 O5 REMOVE SOIL IN SLAYERS AROUND MH TO PREVENT 45 Q SOIL LOADING ON ONE SIDE OF THE MH. 60 CUT UPSIZED PENETRATION WITH POWER SAW, NO HAMMERING ALLOWED. CONNECT NEW SEWER PIPING Oz 0 40 WITH NPC WATERSTOP GROUTING RING, OR EQUAL. FILL Q VOID WITH NON SHRINK GROUT. w O7 REMOVE AND REPLACE MH CHANNEL PER SPECIAL w PROVISIONS SECTION 7-26, EXCEPT EXTEND CHANNEL 35 HEIGHT TO TOP OF 24" SS. OREMOVE EXISTING VEGETATION AS NECESSARY AND REPLACE WITH SEED, FERTILIZER AND MULCH. O9 REMOVE AND REPLACE DISTURBED GRAVEL AND BARK 30 TO MATCH EXISTING. �i �I 10 TRENCH BACKFILL SHALL BE CSTC FOR ALL SEWER 0 o UNDER PAVEMENT. NATIVE MATERIAL FOR TRENCH 25 �I BACKFILL MAY BE USED ELSEWHERE PROVIDED IT n'� MEETS THE REQUIREMENTS OF GRAVEL BORROW PER m o�o WSDOT SECTION 9-03.14(1). INSTALL UNDERGROUND fix WARNING TAPE IN TRENCH PER SPECIAL PROVISIONS �!al C: 1 SECTION 7-08.3(3)B. 20 6- 8 CONSTRUCTION C/L EQUALS PIPE C/L. ziz w Jl�o 12 REPLACE CHANNELIZATION MARKERS PER RENTON STD K4 PLANS H007, 109 AND 109.1. 15 WIo 'I� X BHC Consultants, LLC 1601 Fifth Avenue, Suite 500 Seattle, Washington 98101 t ; � � 206.505.3400 C J ��. t-� z 206.505.3406 (fax) Y SEATTLE TACOMA www.bheconsultants.com ' X EX 24" VCP SS FIELD VERIFY I E, TYP EX 24" VCP SS, SEE DWG C-3 } SEWER RELINE REQUIREMEN PROTECT EXIST UTILITIES, TYP EXISTING RIGHT OF WAY ENTERPRISE CAR RENTAL AC ram• � AC 441 co 02 C/L SUNSET BLVD N CL I APPROX EX APPROX FINISHED w w FENCE LINE GRADE AT CONSTRUCTION C/L o �—� ---_ a X W C) LO 00 C- i / rn / I z w /'�L VERIFY DEPTH OF EX UTILITIES, TYP _ _„PVC SS ITH 122+_ OF S ^I �CO O?w N Z R W WIN N Imo- CMCMM WWw LJ O N v 1+ 0 Es W, 49545 �0- GjST��ti��w�( (j sSjONAL S AND ¢EP�p,CE W EX12"uCPS 101 F 10 PIPE TRENCH DETAIL PER RENTON STD PLAN 110 LO LO 6 X 7 I N M 2+00 N N M �LO =J �w W2 w0� II I� _ J z I­_z o 00 NW r` 00 r- cl i * I,"q, Ww WAA SURVEYED: SCALE: VERTICAL: NAVD 1988 KPG HORIZ: 1 "_ 1 0'_0" HORIZONTAL: NAD 1983/1991 DESIGNED: T. WHITEHOUSE, P.E. VERT: 1 "=5'-0" DRAWN: w� P. SIMON ONE INCH DATUM WV " ISSUED FOR BID TJW 05/2015 JSK CHECKED: AT FULL SCALE �4 TE J. KRESHEL, P.E. IF NOT ONE INCH SIGNAL SCALE ACCORDINGLY NO. REVISION BY DATE APPR APPROVED: R. DORN, P.E. cM P i- Q 'a p ; • ° a ~ 11 CONSTRUCTION � CENTERLINE 'o ----. w Z Q � ' � 4 - 65 m 55 50 45 40 35 25 20 15 Ad CITY 0E mu RENTON Public Works Dept. NOTES: 1. CONTRACTOR SHALL PREPARE AND SUBMIT FOR REVIEW AND APPROVAL A TRAFFIC CONTROL PLAN FOR WORK IN SUNSET BLVD N. THE TRAFFIC CONTROL PLAN SHALL BE APPROVED BY THE ENGINEER PRIOR TO BEGINNING ANY WORK IN SUNSET BLVD N AND BE IN ACCORDANCE WITH THE CITY APPROVED ROW PERMIT TO BE OBTAINED BY THE CONTRACTOR. SEE DWG G-2 FOR ADDITIONAL TRAFFIC CONTROL NOTES. 2. SEE SPECIAL PROVISIONS SECTION 7-27 FOR TEMPORARY SEWER BYPASS PUMPING/SYSTEMS REQUIREMENTS. 3. REFER TO GEOTECHNICAL ENGINEERING REPORT (AVAILABLE FOR REFERENCE ONLY) FOR INFORMATION ON PROJECT SOIL BORINGS AB-1, AB-2, GB-14 AND GB-15. 4. SEE GENERAL BNSF NOTES AND REQUIREMENTS ON DWG G-2. 5. ALL MANHOLE EXCAVATION SHALL HAVE AN ENGINEERED SHORING PLAN (PE SEALED) APPROVED BY BNSF PRIOR TO CONSTRUCTION. CONTRACTOR SHALL SUBMIT SHORING PLAN THREE WEEKS PRIOR TO CONSTRUCTION FOR ENGINEER AND BNSF APPROVAL, SEE WSDOT SECTION 2-09 FOR STRUCTURAL SHORING REQUIREMENTS. 6. SEE GENERAL CONSTRUCTION SEQUENCE NOTES ON DWG G-2. 7. THE LOCATION OF EXISTING UTILITIES SHOWN ARE APPROXIMATE- TAKEN FROM UTILITY LOCATE MARKINGS AND/OR AVAILABLE RECORD DRAWINGS. DEPTHS OF WATER, NATURAL GAS, AND UNDERGROUND POWER, TELEPHONE, CABLE, AND/OR FIBER OPTIC MAINS AND SERVICES ARE UNKNOWN. EXACT LOCATIONS MUST BE DETERMINED BY THE CONTRACTOR PRIOR TO AND DURING CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL DAMAGES CAUSED DUE TO FAILURE TO LOCATE AND PRESERVE ANY/ALL EXISTING UTILITIES. 8. EROSION CONTROL MEASURES SHALL BE PROVIDED/IMPLEMENTED AS REQD AND APPROPRIATE IN ACCORDANCE WITH THE EROSION CONTROL NOTES ON DWG G-2 AND APPLICABLE CITY OF RENTON STD PLANS. 9. REMOVE AND DISPOSE OF EXISTING SEWER PIPE, MANHOLE AND APPURTENANCES IN ACCORDANCE WITH THE SPECIFICATIONS. 10. THE LOCATION AND DEPTH OF EXISTING SEWER, MANHOLES AND RELATED APPURTENANCES ARE APPROXIMATE AND SHALL BE FIELD VERIFIED/LOCATED BY THE CONTRACTOR TO RECONNECT AND/OR TIE-IN NEW AND EXISTING SYSTEM FACILITIES. ADJUSTMENTS SHALL BE MADE AS REQUIRED AND NECESSARY. 11. ALL EXCAVATIONS SHALL BE CLOSED UP OR PROTECTED AT THE END OF EACH WORK DAY. Call 48 Hours 12. SEE SPECIAL PROVISIONS SECTION 1-08.13 Before You Di FOR SPECIFIC WORK CONSTRAINTS. g 1-800-424-5555 UNDERGROUND SERVICE S=03 712 DATE: CENTRAL RENTON SEWER INTERCEPTOR Y 2015 FIELDBO RELINE & UPSIZE PROJECT PAGE: DRAWING NO: SEWER UPSIZE PLAN & PROFILE C - 1 SHEET: OF: 4 6 Z X -0 m') t z =z z yC0 0 �m m- m aK co,u m z m m 0 n i r > 71 U �30 o°o ' � C zm[n D) r{ r> 'z �zm _ ~ ED 0 S n CIT -Ti z cn 0 0 A m D Z G: C m �z �rn ��z o O> ww1�� t o� 1 az o �z� t7 W c N