HomeMy WebLinkAboutWWP2703712.9N LEGEND: ABBREVIATIONS SYMBOLS AND DESIGNATIONS
T
co EXISTING PROPOSED AASHTO AMERICAN ASSOC. OF STATE MBMFR MANUFACTURER �
— — — — — — — — RIGHT OF WAY --•••--•••— BNSF PREMISES HIGHWAY MH MANHOLE
TRANSPORTATION OFFICIALS MIN MINIMUM TITLE
N AB ANCHOR BOLT MON MONUMENT TITLE DETAIL NUMBER
CENTERLINE GRAVITY SEWER AC ASPHALT CONCRETE MUTCD MANUAL ON UNIFORM TRAFFIC
ACP ASPHALT CONCRETE PAVEMENT CONTROL DEVICES DETAIL
PROPERTY LINE SANITARY SEWER MANHOLE OR STRUCTURE ADS POLYETHYLENE PIPE MW MONITORING WELL
A�r
ALD ALDER SCALE: 1/2" = 1'-0" C-2
EASEMENT ///////////, TO BE REMOVED OR ABANDONED APPROX APPROXIMATE N NORTH DRAWING NUMBER WHERE DETAIL
IS REFERENCED. USE DASH IF
APWA AMERICAN PUBLIC WORKS NAD NORTH AMERICAN DATUM DETAIL APPEARS ON THE SAME
CONTOUR ASPHALT CONCRETE PAVEMENT (ACP) -PLAN ASSOCIATION NAVD NORTH AMERICAN VERTICAL DATUM
li AVE AVENUE NE NORTHEAST SHEET AS SHEET REFERENCED.
MICA MONUMENT IN CASE is PRE -CAST CONCRETE NIC NOT IN CONTRACT
MON SURFACE MONUMENT °000� �o CSBC BF BLIND FLANGE NO. NUMBER TITLE
BH BORE HOLE NTS NOT TO SCALE TITLE SECTION ELEVATION OR
BLVD BOULEVARD NW NORTHWEST PROFILE REFERENCE LETTER
0 PK NAIL BM BENCH MARK SECTION A
BNSF BURLINGTON NORTHERN SANTA FE OC ON CENTER SCALE: 112" = 1'-0"
REBAR &CAP OD OUTSIDE DIAMETER DASH IF SECTION IS TAKEN ON THE
CB CATCH BASIN OH OVERHEAD SAME DRAWING. USE DRAWING
SEWER MANHOLE CCW COUNTER CLOCK WISE OP OVERHEAD POWER NUMBER IF SECTION WAS TAKEN
CDF CONTROLLED DENSITY FILL OPG OPENING ON A DIFFERENT SHEET.
POWER POLE
CF CLEARING LIMIT FENCE
CHLK CHAIN LINK P POWER SECTION LETTER
POWER POLE W/UNDERGROUND CONNECT CIPP CURED IN PLACE PIPE PE PLAIN END, PROFESSIONAL ENGINEER
GUY ANCHOR C/L, CL CENTERLINE PG PERFORMANCE GRADE A -
CLR CLEAR PSF POUNDS PER SQUARE FOOT C-1
CO CLEANOUT PSI POUNDS PER SQUARE INCH DRAWING NUMBER WHERE DETAIL CALLOUT
POWER MANHOLE CONC CONCRETE PVC POLYVINYL CHLORIDE SECTION IS DRAWN. USE DASH IF
CPLG COUPLING PVMT PAVEMENT SECTION APPEARS ON SAME 4/C-1
TELEPHONE MANHOLE CSBC CRUSHED SURFACING BASE COURSE PWR POWER SHEET AS CUT.
CSTC CRUSHED SURFACING TOP COURSE DRAWING #
GAS VALVE
RD ROAD ELEVATION LETTER DETAIL #
WATER VALVE D/W DRIVEWAY REINF REINFORCEMENT A
D DEPTH, DOUBLE REQ'D REQUIRED
DBH DIAMETER BREAST HEIGHT RET RETAINING C-1
WATER METER
DI DUCTILE IRON ROW, RAN RIGHT OF WAY �— DRAWING NUMBER WHERE ELEVATION IS
DIA DIAMETER RRC RED REBAR AND CAP DRAWN. USE DASH IF ELEVATION
WATER VAULT LID DIP DUCTILE IRON PIPE RT RIGHT APPEARS ON SAME SHEET AS
DIPS DUCTILE IRON PIPE SIZE REFERENCED.
FIRE HYDRANT
DR DRIVE S SOUTH, SLOPE
DTREE DECIDUOUS TREE SCH SCHEDULE
BLOW -OFF DWG DRAWING SD STORM DRAIN
BORE SITE (W/ FIELD DESCRIPTION) SDMH STORM DRAIN MANHOLE PIPING DESIGNATIONS
E EAST, ELECTRICAL SDR STANDARD DIMENSION RATIO
MONITORING WELL EA EACH SE SOUTHEAST
EW EACH WAY SERV SERVICE
EL, ELEV ELEVATION SF SILT FENCE PIPING IS IDENTIFIED BY ITS SIZE FOLLOWED BY PIPING SYSTEM AS FOLLOWS:
GUARD POST EP EDGE OF PAVEMENT SSFM SANITARY SEWER FORCE MAIN
DESIGNATES NEW PIPING:
EX EXISTING SMH SEWER MANHOLE
SIGN SS SANITARY SEWER
FF FINSHED FLOOR SST STAINLESS STEEL 8" SS
SHRUB FG FINISH GRADE ST STREET
PVC
FT,' FEET STA STATION
DECIDUOUS TREE, DIA (# OF TRUNKS)
STD STANDARD DESIGNATES EXISTING PIPING:
PAINTED POWER G GAS STL STEEL
GALV GALVANIZED SW SOUTHWEST
GRAY GRAVEL EX 8" CONIC SS
PAINTED TELEPHONE GV GATE VALVE T TELEPHONE
T&B TOP AND BOTTOM
PAINTED FIBER IOPTIC HDPE HIGH DENSITY POLYETHYLENE TBM TEMPORARY BENCHMARK FOR NEW PIPING MATERIAL, FITTINGS, AND VALVES, SEE SPECIFICATIONS. A
HMA HOT MIX ASPHALT TELJB TELEPHONE JUNCTION BOX GENERAL PIPING MATERIAL MAY BE NOTED.
PAINTED TV HORIZ HORIZONTAL TELR TELEPHONE RISER
HT HUB AND TACK TV TELEVISION (CABLE) PIPING SYSTEM DESIGNATIONS FOR EXISTING PIPING INDICATE TYPE OF
PAINTED WATER HYD HYDRANT TVJB TELEVISION (CABLE) JUNCTION BOX SERVICE AND TYPE OF MATERIAL IF KNOWN. CONTRACTOR SHALL VERIFY ALL
PAINTED GAS TVR TELEVISION (CABLE) RISER EXIST PIPE MATERIAL AND NOT RELY ON THIS DESIGNATION PRIOR TO
ID INSIDE DIAMETER TYP TYPICAL CONSTRUCTION.
IE INVERT ELEVATION
SEWER IN, " INCH UGP UNDERGROUND POWER
IPS IRON PIPE SIZE UNO UNLESS NOTED OTHERWISE
FENCE
JB JUNCTION BOX VCP VITRIFIED CLAY PIPE
RAISED -BUTTON SOLID STRIPE VERT VERTICAL DRAWING REFERENCE
RAISED -BUTTON SKIP STRIPE L LENGTH
LF LINEAR FEET W/ WITH
LN LANE W WATER, WEST G GENERAL
EDGE OF PAVEMENT
LT LEFT WL WATER LEVEL C CIVIL
WM WATER METER
CONCRETE S=371203
MAX MAXIMUM WSDOT WASHINGTON STATE DEPARTMENT
�o' MB MAIL BOX OF TRANSPORTATION
GRAVEL
MDD MAXIMUM DRY DENSITY WS WATER SERVICE
0
RECORD DRAWING
These record drawings have been prepare
1 based on construction records and as -built
C:information provided by the contractor and Call 48 Hours
others. BHC Consultants, LLC has not
verified the accuracy and/or completeness Before You Dig
of this information_
I�
1-800-424-5555
UNDERGROUND SERVICE
I
BHC Consultants LLC ** **
I, DATE
E ORIGINAL ORIGINAL SURVEYED sccLe
KPG VERTICAL: NAVD ,988 MAY 2015
ti 1601 Fifth Avenue, Suite 500 SEALED BY: SEALED BY: DESIGNED: N/A "°RIZ°NT NAD ,g83,,9g, C 1 Y CENTRAL RENTON SEWER INTERCEPTOR
. Seattle, Washin ton 98101 T. wHITEHousE, P.E. RELINE & UPSIZE PROJECT
F'E DB°°K:
\ s 9 TYLER JAMES WHITEHOUSE JEFFREY S. KRESHEL T
K' 206.505.3400 5/14/15 5/14/15 RECORD DRAWING TJW' DRAW": tR I V 0 �1
C O IY U L I AN I 206.505.3406 fax PAGE:
2�2016 R.AD P. SIMON DRAWING No:
49545 32796 ONE 'Nc" I DATUM G
(fax) ISSUED FOR BID TJU� 05/015 JSK CHECKED:AT Public works Dept. LEGEND, ABBREVIATIONS, SYMBOLS & DESIGNATIONS
SEATTLE T�4rOMA www.bhcconsultants.com
** ** J. KRESHEL, P.E. IF NOT ONELL INCH
PR APPROVED SCALE ACCORDINGLY SHEET: OF:
N0. REVISION BY DATE AP
t_
R. DORN,
D
7J
0
�Cz
i C C
7
f
im
C 0
C
M
C � _
^ Cn
Ul �_
m
W
N z
ITI
z
Mm
O
D
D
T
0
0
033
0
ao
'AU)
'D
Dm
iC
�O
m�
i Nm
cn
ru z
z
m
O
D
�
z
v�
>
r
zz
1
�o
SID
y
� 1
N-
1
mm
�
m
�
~w�
o
D
T
0
0
a
00
D
Mc
m