Loading...
HomeMy WebLinkAboutWWP2703712.9N LEGEND: ABBREVIATIONS SYMBOLS AND DESIGNATIONS T co EXISTING PROPOSED AASHTO AMERICAN ASSOC. OF STATE MBMFR MANUFACTURER � — — — — — — — — RIGHT OF WAY --•••--•••— BNSF PREMISES HIGHWAY MH MANHOLE TRANSPORTATION OFFICIALS MIN MINIMUM TITLE N AB ANCHOR BOLT MON MONUMENT TITLE DETAIL NUMBER CENTERLINE GRAVITY SEWER AC ASPHALT CONCRETE MUTCD MANUAL ON UNIFORM TRAFFIC ACP ASPHALT CONCRETE PAVEMENT CONTROL DEVICES DETAIL PROPERTY LINE SANITARY SEWER MANHOLE OR STRUCTURE ADS POLYETHYLENE PIPE MW MONITORING WELL A�r ALD ALDER SCALE: 1/2" = 1'-0" C-2 EASEMENT ///////////, TO BE REMOVED OR ABANDONED APPROX APPROXIMATE N NORTH DRAWING NUMBER WHERE DETAIL IS REFERENCED. USE DASH IF APWA AMERICAN PUBLIC WORKS NAD NORTH AMERICAN DATUM DETAIL APPEARS ON THE SAME CONTOUR ASPHALT CONCRETE PAVEMENT (ACP) -PLAN ASSOCIATION NAVD NORTH AMERICAN VERTICAL DATUM li AVE AVENUE NE NORTHEAST SHEET AS SHEET REFERENCED. MICA MONUMENT IN CASE is PRE -CAST CONCRETE NIC NOT IN CONTRACT MON SURFACE MONUMENT °000� �o CSBC BF BLIND FLANGE NO. NUMBER TITLE BH BORE HOLE NTS NOT TO SCALE TITLE SECTION ELEVATION OR BLVD BOULEVARD NW NORTHWEST PROFILE REFERENCE LETTER 0 PK NAIL BM BENCH MARK SECTION A BNSF BURLINGTON NORTHERN SANTA FE OC ON CENTER SCALE: 112" = 1'-0" REBAR &CAP OD OUTSIDE DIAMETER DASH IF SECTION IS TAKEN ON THE CB CATCH BASIN OH OVERHEAD SAME DRAWING. USE DRAWING SEWER MANHOLE CCW COUNTER CLOCK WISE OP OVERHEAD POWER NUMBER IF SECTION WAS TAKEN CDF CONTROLLED DENSITY FILL OPG OPENING ON A DIFFERENT SHEET. POWER POLE CF CLEARING LIMIT FENCE CHLK CHAIN LINK P POWER SECTION LETTER POWER POLE W/UNDERGROUND CONNECT CIPP CURED IN PLACE PIPE PE PLAIN END, PROFESSIONAL ENGINEER GUY ANCHOR C/L, CL CENTERLINE PG PERFORMANCE GRADE A - CLR CLEAR PSF POUNDS PER SQUARE FOOT C-1 CO CLEANOUT PSI POUNDS PER SQUARE INCH DRAWING NUMBER WHERE DETAIL CALLOUT POWER MANHOLE CONC CONCRETE PVC POLYVINYL CHLORIDE SECTION IS DRAWN. USE DASH IF CPLG COUPLING PVMT PAVEMENT SECTION APPEARS ON SAME 4/C-1 TELEPHONE MANHOLE CSBC CRUSHED SURFACING BASE COURSE PWR POWER SHEET AS CUT. CSTC CRUSHED SURFACING TOP COURSE DRAWING # GAS VALVE RD ROAD ELEVATION LETTER DETAIL # WATER VALVE D/W DRIVEWAY REINF REINFORCEMENT A D DEPTH, DOUBLE REQ'D REQUIRED DBH DIAMETER BREAST HEIGHT RET RETAINING C-1 WATER METER DI DUCTILE IRON ROW, RAN RIGHT OF WAY �— DRAWING NUMBER WHERE ELEVATION IS DIA DIAMETER RRC RED REBAR AND CAP DRAWN. USE DASH IF ELEVATION WATER VAULT LID DIP DUCTILE IRON PIPE RT RIGHT APPEARS ON SAME SHEET AS DIPS DUCTILE IRON PIPE SIZE REFERENCED. FIRE HYDRANT DR DRIVE S SOUTH, SLOPE DTREE DECIDUOUS TREE SCH SCHEDULE BLOW -OFF DWG DRAWING SD STORM DRAIN BORE SITE (W/ FIELD DESCRIPTION) SDMH STORM DRAIN MANHOLE PIPING DESIGNATIONS E EAST, ELECTRICAL SDR STANDARD DIMENSION RATIO MONITORING WELL EA EACH SE SOUTHEAST EW EACH WAY SERV SERVICE EL, ELEV ELEVATION SF SILT FENCE PIPING IS IDENTIFIED BY ITS SIZE FOLLOWED BY PIPING SYSTEM AS FOLLOWS: GUARD POST EP EDGE OF PAVEMENT SSFM SANITARY SEWER FORCE MAIN DESIGNATES NEW PIPING: EX EXISTING SMH SEWER MANHOLE SIGN SS SANITARY SEWER FF FINSHED FLOOR SST STAINLESS STEEL 8" SS SHRUB FG FINISH GRADE ST STREET PVC FT,' FEET STA STATION DECIDUOUS TREE, DIA (# OF TRUNKS) STD STANDARD DESIGNATES EXISTING PIPING: PAINTED POWER G GAS STL STEEL GALV GALVANIZED SW SOUTHWEST GRAY GRAVEL EX 8" CONIC SS PAINTED TELEPHONE GV GATE VALVE T TELEPHONE T&B TOP AND BOTTOM PAINTED FIBER IOPTIC HDPE HIGH DENSITY POLYETHYLENE TBM TEMPORARY BENCHMARK FOR NEW PIPING MATERIAL, FITTINGS, AND VALVES, SEE SPECIFICATIONS. A HMA HOT MIX ASPHALT TELJB TELEPHONE JUNCTION BOX GENERAL PIPING MATERIAL MAY BE NOTED. PAINTED TV HORIZ HORIZONTAL TELR TELEPHONE RISER HT HUB AND TACK TV TELEVISION (CABLE) PIPING SYSTEM DESIGNATIONS FOR EXISTING PIPING INDICATE TYPE OF PAINTED WATER HYD HYDRANT TVJB TELEVISION (CABLE) JUNCTION BOX SERVICE AND TYPE OF MATERIAL IF KNOWN. CONTRACTOR SHALL VERIFY ALL PAINTED GAS TVR TELEVISION (CABLE) RISER EXIST PIPE MATERIAL AND NOT RELY ON THIS DESIGNATION PRIOR TO ID INSIDE DIAMETER TYP TYPICAL CONSTRUCTION. IE INVERT ELEVATION SEWER IN, " INCH UGP UNDERGROUND POWER IPS IRON PIPE SIZE UNO UNLESS NOTED OTHERWISE FENCE JB JUNCTION BOX VCP VITRIFIED CLAY PIPE RAISED -BUTTON SOLID STRIPE VERT VERTICAL DRAWING REFERENCE RAISED -BUTTON SKIP STRIPE L LENGTH LF LINEAR FEET W/ WITH LN LANE W WATER, WEST G GENERAL EDGE OF PAVEMENT LT LEFT WL WATER LEVEL C CIVIL WM WATER METER CONCRETE S=371203 MAX MAXIMUM WSDOT WASHINGTON STATE DEPARTMENT �o' MB MAIL BOX OF TRANSPORTATION GRAVEL MDD MAXIMUM DRY DENSITY WS WATER SERVICE 0 RECORD DRAWING These record drawings have been prepare 1 based on construction records and as -built C:information provided by the contractor and Call 48 Hours others. BHC Consultants, LLC has not verified the accuracy and/or completeness Before You Dig of this information_ I� 1-800-424-5555 UNDERGROUND SERVICE I BHC Consultants LLC ** ** I, DATE E ORIGINAL ORIGINAL SURVEYED sccLe KPG VERTICAL: NAVD ,988 MAY 2015 ti 1601 Fifth Avenue, Suite 500 SEALED BY: SEALED BY: DESIGNED: N/A "°RIZ°NT NAD ,g83,,9g, C 1 Y CENTRAL RENTON SEWER INTERCEPTOR . Seattle, Washin ton 98101 T. wHITEHousE, P.E. RELINE & UPSIZE PROJECT F'E DB°°K: \ s 9 TYLER JAMES WHITEHOUSE JEFFREY S. KRESHEL T K' 206.505.3400 5/14/15 5/14/15 RECORD DRAWING TJW' DRAW": tR I V 0 �1 C O IY U L I AN I 206.505.3406 fax PAGE: 2�2016 R.AD P. SIMON DRAWING No: 49545 32796 ONE 'Nc" I DATUM G (fax) ISSUED FOR BID TJU� 05/015 JSK CHECKED:AT Public works Dept. LEGEND, ABBREVIATIONS, SYMBOLS & DESIGNATIONS SEATTLE T�4rOMA www.bhcconsultants.com ** ** J. KRESHEL, P.E. IF NOT ONELL INCH PR APPROVED SCALE ACCORDINGLY SHEET: OF: N0. REVISION BY DATE AP t_ R. DORN, D 7J 0 �Cz i C C 7 f im C 0 C M C � _ ^ Cn Ul �_ m W N z ITI z Mm O D D T 0 0 033 0 ao 'AU) 'D Dm iC �O m� i Nm cn ru z z m O D � z v� > r zz 1 �o SID y � 1 N- 1 mm � m � ~w� o D T 0 0 a 00 D Mc m