HomeMy WebLinkAboutTRO4103718.12:
a
a�
0
Y
O
L
U
C
m
C
n
I
I'
I'
I !
1
„ I
f
5 � I
'Atyac .
m
a
6
.. _ , r _.. ....,._.
r
i
r
, r
r r
(p {r
1 / 4
Q9--- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------------------- - - - - ------------ - ---- -- --------- -
i
z - - - - - - - - - - - - - - - - - -
,r
r: s,
0
N
o �. SE 172ND ST 1
z ae�at3��:�t3 1
'
,m __. ._.. �, __ .... 1 i
_/
1 tD(I /
iBRASS [SK r _ _ 15+00
0
b7
at� .
_._
w 00
M �,. _, .__�,, _. .._ ._�.:. ..... _.
S J
O . , ...
1�
CD
; t as 6&
., _.
z
r
S3C
r
W
W
N
W
o
w
U
a
Q
__
a-
0o
Q
'2
N
W
N
11
M
11
n
1
Q
N
\
\
m
m
z
O
Cn
w
m
O
z
LUM.
N0,
POLE *
ID. N0.
CIRCUIT
N0.
LOCATION
OFFSET
(FEET)
LED LAMP
WATTAGE
MAST ARM
(FEET)
MOUNTING
HGT, (FT.)
STANDARD
PLAN #
1
4376
W-
A
108tTH AVE SE 4+11
26.0' RT
60 LED
4'
14'
117.2
2. ;.
M 7
Ui
A
108tTH AVE SE 3+45
26.0' RT
13.r -,�- Se 60
6' 4'
3514'
117.1
3--1371
M
A
108TH AVE SE 2+51
26.0' RT
Js 2- 3 60
6' 4'
3514'
117.1
4-
18
A
108TH AVE SE 1+57
26.0' RT
ss - 60
6' 4'
3514'
117.1
5
43
A
SE 172ND ST 10+62
19.5' LT
44 LED
NA
14'
116.1
6
',3 Lk
, =
A
A
A
SE 172ND ST 11+72
19.5' RT
44 LED
NA
14'
116.1
7
SE 172ND ST 12+82
19.5' LT
44 LED
NA
14'
116.1
8
° `
SE 172ND ST 13+92
19.5' LT
44 LED
NA
14'
116.1
g
A
SE 172ND ST 15+02
19.5' LT
44 LED
NA
14'
116.1
10
A
SE 172ND ST 16+25
19.5' LT
44 LED
NA
14'
116.1
11
y38q
r A
1A A
SE 172ND ST 17+12
51.5' LT
44 LED
NA
14'
116.1
12
4310
SE 172ND ST 17+67
14.0' RT
44 LED
NA
14'
116.1
13
143cl1
,-- I
A
SE 172ND ST 16+82
1 39.5' RT
44 LED
NA
14
116.1
* TO BE NUM_ BERED AT TIME OF CONSTRUCTION
;i�E 5hEEl 1L1 1-ok NDDi►1014P�L 'LN" oKMATJOW
WIRING SCHEDULE
CONDUIT
RUN
CONDUIT
SIZE
CONDUCTORS
NOTES
1
2.0" PVC (SCHEDULE 40)
2-#8, 1-#8 GREEN
2
2.0 PVC SCHEDULE 80
2-#8, 1-#8 GREEN
3
2.0" PVC (SCHEDULE 40)
2-#8, 1-#8 GREEN
3-#14 PHOTOCELL
4
2.0" PVC (SCHEDULE 40)
PSE POWER
his 5ff�i�/'
CA UT/DN:
LOCATION OF EXISTING UTILITIES SHOWN IS
APPROXIMATE AND MAY NOT BE ACCURATE
OR ALL INCLUSIVE. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO POTHOLE AS REQUIRED
AND FIELD VERIFY LOCATION OF UTILITIES
PRIOR TO PROCEEDING WITH CONSTRUCTION.
OINSTALL NEIGHB❑RH❑❑D STREET PEDESTRIAN
LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN
1161, CONCRETE F❑UNDATI❑N, AND ASS❑CIATED
JUNCTION BOX PER DETAILS ON SHEET P AND 3, AND
LUMINAIRE POLE SCHEDULE,
O INSTALL ARTERIAL STREET DEC❑RATIVE PEDESTRIAN
LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN
117.2, CONCRETE F❑UNDATI❑N, AND ASSOCIATED
JUNCTI❑N BOX PER DETAILS ON SHEET 2 AND 3, AND
LUMINAIRE POLE SCHEDULE,
30 INSTALL ARTERIAL STREET DEC❑RATIVE ROADWAY
LUMINAIRE FIXTURES AND POLE PER STANDARD PLAN
117,1, CONCRETE F❑UNDATI❑N, AND ASS❑CIATED
JUNCTI❑N BOX PER DETAILS ON SHEET 2 AND 3, AND
LUMINAIRE POLE SCHEDULE.
INSTALL ELECTRICAL SERVICE CABINET # XXX PER
DETAILS ON SHEET 3, LOCATED ON 108TH AVE SE AT
APPR❑XIMATE STATION 4+00, 26' RT. C❑❑RDINATE WITH
PSE FOR SERVICE C❑NNECTION, LABEL BACK OF
CONTACTOR CABINET WITH ADDRESS LOCATION; USE 1"
LETTERS,
O INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD.
LEGEND
NEW
LED PEDESTRIAN LUMINAIRE
AND DECORATIVE POLE
LED ROADWAY LUMINAIRE
AND DECORATIVE POLE
EHO
- - - - - - - PVC CONDUIT (SEE WIRING SCHEDULE)
® TYPE 1 JUNCTION BOX WITH
CONCRETE PAD
I mij I I Vvim
O
RECOMMENDED
FOR APPROVAL
30 0 30 60
BY
scale feet BY
SERVICE CABINET T=3 71805
AWIRE NOTE
CONSTRUCTION NOTE
UNDERGROUND UTILITY NOTE:
YOU MUST CALL 1-800-424-5555 NOT LESS THAN 72 HOURS
BEFORE BEGINNING EXCA VA TION WHERE ANY UNDERGROUND
UTILITIES MAY BE LOCATED, FAILURE TO DO SO COULD MEAN
BEARING SUBSTANTIAL REPAIR COSTS (UP TO THREE TIMES THE
COST OF REPAIRS TO THE SERVICE).
BY
CHECKED FOR COMPLIANCE
• TO CITY STANDARDS
DATE J 9�
DATE
DATE
Traff
NORTHWEST EX
Ti4A FF/C EXPERTS
11410 NE 124th St., #590, Kirkland, WA 98034
Phone:425.522.4118 Fax:425.522.4311
NAL
3-//-!�'f