Loading...
HomeMy WebLinkAboutTRO4103718.30 z 0 W X x �Q o00 ,� 0 x S Ur U Z Z Z Z D O U z 0 0 z � W O w Z 0 to 3 Qq O U w W af a I Q J N Q M N Z 0 LL.I LY Z LUMINAIRE WIRES WILL BE A CONTINUOUS RUN FROM FUSE HOLDER TO FIXTURE WITH NO SPLICES. GROUND ROD FU SE KITS QUICK DISCONNECT TO LUMINAIRE 3 AMP IN LINE FUSE KITS S.E.C. OR EQUAL LUMINAIRE WIRES WALL BE p12 AWG IN A JACKETED CABLE. REFER TO WSOOT LOCKING LID STANDARD —H8 GREEN INSULATED WIRE DUTY JUNCTION BOX TYPES ? & 2 TO FIXTURE GROUND LUG STANDARD PLAN J-40.10-02 GROUND LUG 11/4, MINIMUM 1 I DRAIN HOLE-M '"PLiCE KITS CLEAR EPDXYA KI15 ON ALL THIRD i 2' MIN. GROUT TOP CONCRETE FOUNDATION TO WIRE RUNS WIRE 4" CONCRETE PAD UNDER POLE BASEBE ; V LEVEL WITH 7pp OF SIDEWALK / OR CUR@. I �����1 2' MIN. #8 DARE COPPER I GROUND WIRE GROUND CLAMP 1 -#8 EOUIPMEN WIREW/GREEN INSULATION 2" PVC CCNDUI1 II FROM SERVICE CABINET SYSTEM 2 - LIGHTING SYSTEM WIRES TO CONTACTOR (SIZED AS REQ'D,) CONCRETE - f FOUNDATION I 3' SQ. OR.OI-._- 5/8"z8' COPPER CLAD --- GROUND ROO NOTE-S.. 1. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 2. IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG, 'tY 1� O PUBLIC WORKS �Nzo� DEPARTMENT TYPICAL LIGHTING UNDERGROUND SYSTEM I STD. PLAN - 119 - - PPROVED: Y. L; t II z fi ~ 3' O O o STREET LIGHT POLE -JUNCTION BOX PLAN VIEW I I c I I 4" DEEP I � I e 4 I z . H SIDE VIEW t I - I LIGHTING STANDARD & JUNCTION BOX -= --- ---------- —fit I PLAN VIEW t' I INDIVIDUAL JUNCTION BOX NOTE: I CLASS 'B' CONCRETE TO BE I USED IN CONSTRUCTION OF PAD 1 I T PUBLIC WORKS CONCRETE PAD DETAILS STD. PLAN - 120 i r DEPARTMENT DVEn: , DATE, EPDXY Fll_.l. INLINE SPLICE rnnv�i ril I WYE SPLICE SPLICE KIT FUSE KIT FUSE KIT & SPLICE KIT DETAILS Y O ADOPTED CITY OF RENTON MA Standard plans �F O� LST DATE 11/5/96 NOTES:. All dimensions are minimum. Exact configurations vary among different manufacturers. The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2 Boxes shall be 28% minimum of overall thickness. Lid support members shall be welded to the frame. 4000PS1 concrete is allowed if box reinforcement consists of 6 X 6 — W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep extension boxes. When noted in the contract. Type 2 Boxes shall be provided with a 10' X 27 1 /2" 10 gage divider plate complete with fasteners. Non —concrete Boxes may be submitted for approval. Evaluation will include an H-20 Load Test. JUNCTION BOX DIMENSION TABLE i G I I ITEM BOX TYPE I TYPE 1 TYPt ALTERNATE A ALTERNATE B A Box Outside length 22" 22" 33" B Box Outside Width 17" 1 17" 22 1 2" C Box Inside Length 18" 19" 28" D Box Inside Width 13" 14" 17" E Lid Length 18" 18" 26 1 2" F ILid Width 13" 13" 17" G Box Depth 1 12" 12" 12" H Lid & Frame Depth 5 16" 5 16" 5 16" J Wall Thickness (Min.) 1 1 2" 1 1 2" 1 1 2" K Wire Reinforcement W-3 W-2.5 W-2.5 L Legend See Detail See Detail See Detail ITEM MATERIALS Box 6000 PSI concrete See Notes Frame Diamond Plate Steel — A786 Liupport 1 8"Min. Thick Steel C, L or Lid Diamond Plate Steel — A786 Anchors Steel Wire or Tee Plate Reinforcement ASTM A-82 Steel *GALVANIZED STEEL LEGEND DETAIL_ (Mark L) SIGNALS LIGHTING TS—LT TELEMETRY -Form Letters with 1 /8" Weld Bead. Grind off Diamond Pattern before forming letters. APPR°DI DWG. NAME: JR-12 SP PAGE: J013 DATE M -- .._ ----- - z a All � o= �• wo 15� v a C Za UY 0 IV) O a z t Z U J N 0 O W m U Of � m C ( ' io O� �21N -1 1 tom`! � W ~_ Wl-,j `o �i B z N �o 113 :2 WaE La Re dig j 0o` -� �Y M8K mtK U $�+ y� ;iO o� Inn -jY a 3�m QW N sliGG �U o U_ �> S��Jm Q � 8 AO—O - - _ Noww �e � 3u o o zo �2 o—o - N In zo 1---4 �o �"' �00 �0 t0 1 N z 4. �� LU �Of (�W ��� �3$ cc), O" Z6 QU �fT a��� O�,xJd8�aF� I 4a w qO;y� j HB 0 as I — I I w 1 I I O U I Of C I N I 1 I Z al m I I 0• ' I L--J I _ ,z, U� I — — I w w I I , E- 4. I L — -�1 w ti�Y.O STD; PLAN - 122.1 PUBLIC! WORK15 SERVICE CABINET $ DEPARTMENT WITHOUT BIBS Pt�out ! i fiNrTO _ 1rIC _ I�FA��� [ I 114T TS1 TRAFFIC SIGNAL SYSTEM LEGEND LT= I �1 iLLUMINATION SYSTEM LEGEND REVISION C r"Lhi IV VICYY T— � U s� ^, vk � I� q- BELL ENDS -/ MIN. MAX. ON CONDUIT TYP. 6" GRAVEL PAD COMPACTED TYPICAL JUNCTION BOX INSTALLATION DETAILS Lld m TYPE '1' BOX A TYPE 'II' BOX L7 z1z3/18, 1"Long HOOK DETAIL PLAN SYMBOLS (2 Hooke per Ud) JUNCTION BOX DETAILS Y O� ADOPTED CITY OF RENTON ♦ p W Standard plans F'N o LST DATE: 1 1 /89 DWG. NAME: JR-36 SP PAGE: J016 I I STREET LIGHTING CONTACTOR CABINET WIRING SCHEMATIC � TYPE i.iiSERVICE 120, 240 VOLT I I CS 100 A MAIN BREAKER (MIN.) 2 POLE 240 VOLT 0 0 a m - Q D' BRANCH BREAKERS E 120/240 VOLT z TEST 16 POLE SWITCH — A B i B II TERMINAL B C� C I BLOCK B B -- I B B B A UTjLI PLUG (GFI) T A A A STREET LIGHTING CONTACTORS B B� B I I D I CIRCUIT WIRES TO LIGHTING RUNS A PHOTO -CELL TO GROUND I MOUNTED ON ROD NEAREST LUMINAIRE I WIRING COLOR CODE A. WHITE JACKET (NEUTRAL) B. BLACK JACKET (LINE) C. GREEN JACKET (GROUND) D. RED JACKET (LOAD; E, GREEN OR BARE WIRE (GROUND) STD. PLAN - 123 { + PUBLIC WORKS DEPARTMENT STREET LIGHTING CONTACTOR CABINET SCHEMATIC P ovl �l� ?, �O�, i i oor�A 1 of w,a NOR TH WE.S T T vA -F-1c ExPER Ts 3025 FS FOIST 11410 NE 124th St., #590, Kirkland, WA 98034 S/0NA Phone: 425.522,4118 Fax- 425,522.4311 r �/c sI�E17 . p �,. ■.. �r- IFATA M fell RECOMMENDED FOR APPROVAL BY BY BY CHECKED FOR COMPLIANCE TO CITY STANDARDS DATE y- f _z / II DATE DATE CONDUIT ENTR. AREA e " o'a PLAN VIEW SIZE TO FIT SIZE TO FIT I- CABINET �{ CABINET . " I -Grade Levet N FRONT VIEW SIDE .VIErA' STREET LIGHT CONTACTOR FOUNDATION Shun to plumb ��h�m to plumb ___._ See Note 3 __ —See N.te 3 ;I - #4 hoops ;I {4 hoops O I #4 hof egcll comer — — rf4 bar egch �grne, -- s - ---J �= E" MIN 1 \ ?" to 2' 6" MIN 1" to 2" 3/8" diameter plastid drain 3/8" diameter plastic drain SDe' VIEW SIDE VIEW ?'-6' __ otnet tlepih � 1'-6" Cab{net depth 1'-6" (--- + 2 T— I + 2 —--_� b K4, bar each e_ rner W . `m + —,y4 hoops + p5 d each o bar ner PLAN VIEW PLAN VIEW I PAD MOUNT PAD MOUNT CONTROLLER CABINET FOUNDATION BATTERY BACKUP SYSTEM (BBS) FOUNDATION For NOTES see Std. Plan 126.2 PUBLIC WORKS CABINET FOUNDATION DETAILS RD PLAN - 126.1 DEPARTMENT 1- NT`-F