HomeMy WebLinkAboutTRO4103718.30
z
0
W
X
x
�Q
o00
,�
0
x
S Ur
U
Z Z
Z
Z D
O U
z
0
0
z
�
W
O
w
Z
0
to
3
Qq
O
U
w
W
af
a
I
Q
J
N
Q
M
N
Z
0
LL.I
LY
Z
LUMINAIRE WIRES WILL BE A CONTINUOUS RUN
FROM FUSE HOLDER TO FIXTURE
WITH
NO SPLICES.
GROUND ROD
FU SE KITS QUICK DISCONNECT
TO LUMINAIRE
3 AMP IN LINE FUSE KITS
S.E.C. OR EQUAL
LUMINAIRE WIRES WALL BE p12
AWG IN A JACKETED CABLE.
REFER TO WSOOT LOCKING LID STANDARD
—H8 GREEN INSULATED WIRE
DUTY JUNCTION BOX TYPES ? & 2
TO FIXTURE GROUND LUG
STANDARD PLAN J-40.10-02
GROUND LUG
11/4, MINIMUM
1
I DRAIN HOLE-M
'"PLiCE KITS CLEAR EPDXYA
KI15 ON ALL THIRD
i
2' MIN. GROUT
TOP CONCRETE FOUNDATION TO
WIRE RUNS
WIRE
4" CONCRETE PAD
UNDER POLE BASEBE
;
V
LEVEL WITH 7pp OF SIDEWALK
/ OR CUR@.
I
�����1
2' MIN. #8 DARE COPPER
I GROUND WIRE
GROUND
CLAMP
1 -#8 EOUIPMEN
WIREW/GREEN INSULATION
2" PVC CCNDUI1
II
FROM SERVICE CABINET
SYSTEM
2 - LIGHTING SYSTEM
WIRES TO CONTACTOR
(SIZED AS REQ'D,)
CONCRETE
-
f FOUNDATION I 3' SQ.
OR.OI-._-
5/8"z8' COPPER CLAD
---
GROUND ROO
NOTE-S..
1. EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE
SECURELY FASTENED TO THE GROUND LUG INSIDE THE
POLE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS
SHALL REMAIN ACCESSIBLE FOR INSPECTION AND
MAINTENANCE.
2. IF THE FIXTURE MANUFACTURER HAS MADE PROVISION FOR
THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED
WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE
TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE
FIXTURE MANUFACTURER HAS A GROUND LUG A #8 GREEN
INSULATED WIRE SHALL BE RUN FROM THE FIXTURE
GROUND LUG TO THE POLE GROUND LUG,
'tY
1� O
PUBLIC WORKS
�Nzo� DEPARTMENT
TYPICAL LIGHTING
UNDERGROUND SYSTEM
I STD. PLAN - 119
- -
PPROVED:
Y.
L; t
II
z
fi
~ 3'
O O o
STREET LIGHT POLE
-JUNCTION BOX
PLAN VIEW
I
I
c
I
I
4" DEEP
I
�
I
e 4 I
z
. H
SIDE VIEW
t
I
-
I
LIGHTING STANDARD & JUNCTION BOX -= --- ---------- —fit
I
PLAN VIEW t'
I
INDIVIDUAL JUNCTION BOX
NOTE:
I
CLASS 'B' CONCRETE TO BE
I
USED IN CONSTRUCTION OF PAD
1
I
T
PUBLIC WORKS CONCRETE PAD DETAILS STD. PLAN - 120
i r DEPARTMENT DVEn: ,
DATE,
EPDXY Fll_.l.
INLINE SPLICE
rnnv�i ril I
WYE SPLICE
SPLICE KIT
FUSE KIT
FUSE KIT & SPLICE KIT DETAILS
Y O ADOPTED
CITY OF RENTON
MA
Standard plans
�F O� LST DATE 11/5/96
NOTES:.
All dimensions are minimum. Exact configurations vary among different manufacturers.
The noted lid thickeners overall minimums. The Diamond Pattern for Type 1 or Type 2
Boxes shall be 28% minimum of overall thickness.
Lid support members shall be welded to the frame.
4000PS1 concrete is allowed if box reinforcement consists of 6 X 6 — W3 X W3 welded
wire fabric welded to the frame.
When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep
extension boxes.
When noted in the contract. Type 2 Boxes shall be provided with a 10' X 27 1 /2" 10
gage divider plate complete with fasteners.
Non —concrete Boxes may be submitted for approval. Evaluation will include an H-20
Load Test.
JUNCTION BOX DIMENSION TABLE i G I I
ITEM
BOX TYPE
I TYPE 1
TYPt
ALTERNATE A
ALTERNATE B
A
Box Outside length
22"
22"
33"
B
Box Outside Width
17"
1 17"
22 1 2"
C
Box Inside Length
18"
19"
28"
D
Box Inside Width
13"
14"
17"
E
Lid Length
18"
18"
26 1 2"
F
ILid Width
13"
13"
17"
G
Box Depth
1 12"
12"
12"
H
Lid & Frame Depth
5 16"
5 16"
5 16"
J
Wall Thickness (Min.)
1 1 2"
1 1 2"
1 1 2"
K
Wire Reinforcement
W-3
W-2.5
W-2.5
L
Legend
See Detail
See Detail
See Detail
ITEM
MATERIALS
Box
6000 PSI concrete See Notes
Frame
Diamond Plate Steel — A786
Liupport
1 8"Min. Thick Steel C, L or
Lid
Diamond Plate Steel — A786
Anchors
Steel Wire or Tee Plate
Reinforcement
ASTM A-82 Steel
*GALVANIZED STEEL
LEGEND DETAIL_ (Mark L)
SIGNALS
LIGHTING
TS—LT
TELEMETRY
-Form Letters with 1 /8" Weld
Bead. Grind off Diamond
Pattern before forming
letters.
APPR°DI DWG. NAME: JR-12 SP PAGE: J013 DATE
M
-- .._
----- -
z
a
All � o=
�•
wo 15� v a
C Za UY
0
IV)
O
a
z
t
Z U J N 0
O W m
U Of �
m
C ( ' io
O�
�21N -1 1 tom`! � W
~_
Wl-,j
`o �i B
z N �o 113 :2 WaE La Re dig
j
0o` -� �Y M8K mtK U $�+ y� ;iO
o�
Inn -jY a 3�m
QW N
sliGG �U o
U_
�> S��Jm Q
�
8
AO—O - - _ Noww �e � 3u o
o
zo �2
o—o - N In
zo 1---4 �o �"' �00
�0 t0 1 N z
4. �� LU
�Of (�W ��� �3$
cc),
O" Z6 QU �fT a���
O�,xJd8�aF�
I
4a
w
qO;y�
j
HB 0
as
I —
I
I w
1 I
I
O U I Of C I
N I 1 I Z
al
m
I I 0• '
I L--J
I
_
,z, U�
I — —
I
w
w
I I
, E-
4.
I
L — -�1 w
ti�Y.O
STD; PLAN - 122.1
PUBLIC! WORK15 SERVICE CABINET
$ DEPARTMENT WITHOUT BIBS Pt�out ! i
fiNrTO _ 1rIC _ I�FA���
[ I 114T
TS1
TRAFFIC SIGNAL SYSTEM LEGEND
LT=
I
�1
iLLUMINATION SYSTEM LEGEND
REVISION
C
r"Lhi IV VICYY
T— �
U s� ^,
vk �
I�
q- BELL ENDS -/
MIN. MAX. ON CONDUIT
TYP.
6" GRAVEL PAD
COMPACTED
TYPICAL JUNCTION BOX INSTALLATION DETAILS
Lld
m TYPE '1' BOX
A TYPE 'II' BOX
L7 z1z3/18, 1"Long
HOOK DETAIL PLAN SYMBOLS
(2 Hooke per Ud)
JUNCTION BOX DETAILS
Y O� ADOPTED
CITY OF RENTON
♦ p W Standard plans
F'N o LST DATE: 1 1 /89
DWG. NAME: JR-36 SP PAGE: J016
I
I
STREET LIGHTING CONTACTOR CABINET
WIRING SCHEMATIC
�
TYPE i.iiSERVICE 120, 240 VOLT
I
I
CS
100 A MAIN BREAKER (MIN.)
2 POLE 240 VOLT
0 0
a
m -
Q
D'
BRANCH BREAKERS E
120/240 VOLT z
TEST 16 POLE
SWITCH —
A
B i B
II
TERMINAL B C�
C
I
BLOCK B B
-- I B B B
A UTjLI
PLUG (GFI)
T
A A A STREET LIGHTING
CONTACTORS
B
B� B
I
I
D
I
CIRCUIT WIRES TO LIGHTING RUNS
A
PHOTO -CELL TO GROUND
I
MOUNTED ON ROD
NEAREST
LUMINAIRE
I
WIRING COLOR CODE
A. WHITE JACKET (NEUTRAL)
B. BLACK JACKET (LINE)
C. GREEN JACKET (GROUND)
D. RED JACKET (LOAD;
E, GREEN OR BARE WIRE (GROUND)
STD. PLAN - 123
{
+ PUBLIC WORKS
DEPARTMENT
STREET LIGHTING CONTACTOR
CABINET SCHEMATIC
P ovl
�l� ?,
�O�,
i
i
oor�A 1
of w,a
NOR TH WE.S T
T vA -F-1c ExPER Ts 3025
FS FOIST
11410 NE 124th St., #590, Kirkland, WA 98034 S/0NA
Phone: 425.522,4118 Fax- 425,522.4311
r
�/c sI�E17
. p �,. ■.. �r-
IFATA
M fell
RECOMMENDED
FOR APPROVAL
BY
BY
BY
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
DATE y- f _z
/
II
DATE
DATE
CONDUIT ENTR. AREA
e "
o'a
PLAN VIEW
SIZE TO FIT SIZE TO FIT
I- CABINET �{ CABINET
. " I -Grade Levet
N
FRONT VIEW SIDE .VIErA'
STREET LIGHT CONTACTOR FOUNDATION
Shun to plumb ��h�m to plumb
___._ See Note 3 __ —See N.te 3
;I - #4 hoops ;I {4 hoops
O I #4 hof egcll comer — — rf4 bar egch �grne,
-- s - ---J
�=
E" MIN 1 \ ?" to 2' 6" MIN 1" to 2"
3/8" diameter plastid drain 3/8" diameter plastic drain
SDe' VIEW SIDE VIEW
?'-6' __ otnet tlepih � 1'-6" Cab{net depth 1'-6"
(--- + 2 T— I + 2 —--_�
b
K4, bar each
e_
rner
W .
`m
+
—,y4 hoops
+
p5
d each
o bar
ner
PLAN VIEW PLAN VIEW
I
PAD MOUNT PAD MOUNT
CONTROLLER CABINET FOUNDATION BATTERY BACKUP SYSTEM (BBS) FOUNDATION
For NOTES see Std. Plan 126.2
PUBLIC WORKS CABINET FOUNDATION DETAILS RD PLAN - 126.1
DEPARTMENT
1-
NT`-F