No preview available
HomeMy WebLinkAboutTRO4103729.1M SC� 29, T2. 25 N., RGE. 5 E WA. M Y Z _ ---- i II ! I _ !I ---- - -- - <' '�f — 1 ! I I E! ! , : , In , 0 , 1 ' : �I I , r I. , ! 6 4+� —1 _ Xo n s t _ o . e . e z F 2 I' { 8THi Q 3X I 1 D 1 i 2 o � I� I � f I 1 � ! 1� ! U) EX. 150W PSE t o 1 1 ; I. L LUMINAIRE TO REMAIN. o 13 ------------ : ° Lj_�1 a _ .._ V ° ° : - .�° ► C ! / ,_ r f F------------- W j \� ; � `tea �\ `` h - �-_ �: 6 , \ tiei [Y' ! . i \� i `�\\ ! 14 •----------- \___________ _____ _ ____________ QO 5 ZZ o . -� _, .� =J \ \�. Qzz z J EX. 150W PSE r <� LUMINAIRE TO REMAIN` X' BEN'ER A N GTE 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT CITY OF RENTON STANDARD SPECIFICATIONS AND STANDARD DETAILS. .� \ 2. ALL JUNCTION BOXES SHALL BE IN ACCORDANCE WITH WSDOT STANDARD PLAN J-40.10-03. ANY JUNCTION BOX PLACED WITHIN SIDEWALK OR DRIVEWAY SHALL11 w _ EX. 150W PSE` \� HAVE ANTI—SKID LID AND FRAME. LUMINAIRE TO REMAIN a 3. INSTALL ALL FOUNDATIONS, POLES, LUMINAIRES, JUNCTION BOXES PER POLE \ \ Q SCHEDULE AND CITY STANDARD DETAILS ON SHEETS IL2, IL3 AND IL4. w Q 4. INSTALL ALL CONDUIT AND WIRING PER WIRING SCHEDULE AND CITY STANDARD \\ 0 DETAILS ON SHEETS IL2, IL3 AND IL4. m \ SOSI CRU CT ON NOTES OINSTALL FOUNDATION AND ELECTRICAL SERVICE CABINET AT S 28TH ST, STA. 11+04.5, 18.0' LT. CABINET SHALL HAVE TWO ILLUMINATION CIRCUITS MINIMUM. USE CITY STANDARD DETAILS 122.1 AND 126.1. LABEL CABINET AS 2O COORDINATE WITH PUGET SOUND ENERGY (PSE) FOR NEAREST ELECTRICAL o POINT OF SERVICE. ROUTE SERVICE ENTRANCE CONDUIT AND CONDUCTORS TO POINT OF SERVICE PER PSE REQUIREMENTS. COORDINATE WITH PSE FOR SERVICE CONNECTION. 3OCONSTRUCT FOUNDATION AND RELOCATE EXISTING FLASHING BEACON ASSEMBLY TO NEW FOUNDATION. RELOCATE EXISTING JUNCTION BOX WITHIN FIVE FEET OF NEW FOUNDATION. INTERCEPT EXISTING CONDUIT AND ROUTE TO RELOCATED JUNCTION BOX. INSTALL 2" SCHEDULE 40 PVC CONDUIT FROM JUNCTION BOX TO NEW FOUNDATION. INSTALL AND TERMINATE EXISTING CONDUCTORS. USE WSDOT STANDARD PLAN J-21.10-03. 0 z pR �'� pF w,aS � � z 30730 0 X\ RFOtSTER�O ASS/ONAL ENG\ LEGEND PEDESTRIAN POLE, LUMINAIRE, FOUNDATION AND TYPE 1 JUNCTION BOX WITH CONCRETE PAD ARTERIAL POLE, LUMINAIRES, FOUNDATION AND TYPE 1 JUNCTION BOX WITH CONCRETE PAD ARTERIAL POLE, LUMINAIRES, FOUNDATION AND TYPE 2 JUNCTION BOX WITH CONCRETE PAD FLASHING BEACON ASSEMBLY TYPE 1 JUNCTION BOX WITH CONCRETE PAD TYPE 2 JUNCTION BOX WITH CONCRETE PAD ® ELECTRICAL SERVICE CABINET ----- PVC CONDUIT (SEE WIRING SCHEDULE) WIRE NOTE CONSTRUCTION NOTE T-31290 RECORD DOCUMENT BY DATE RECOMMENDED FOR APPROVAL BY DATE BY DATE BY DATE H ERMAN TRAFFIC ENGINEERING 15324 Southeast 133rd Court, Renton, Washington 98059 425-277-1 740 tel. 425-277-5718 fax hte@comcast.net L _F 5-7—w-GiU1