Loading...
HomeMy WebLinkAboutWWP2703729.2A PORTION OF THE NW 1/4 OF SECTION 29, TWP. 23 N., RGE. 5 E, KING COUNTY, WA FF=445.50 / SSMH 13, TYPE 1 —48"4 / / I STA. 10+24.88, 23.50' RT. RI M=434.06 i IE IN=425.42 8" 0 "SE / / r IE OUT=425.32, 8 NW CONTRACTOR TO VERIFY SIZE AND DEPTH PRIOR TO CONSTRUCTION, AND NOTIFY ENGINEER OF ANY DISCREPANCIES . 1 --------------------------------- I 33+00 0 34+00 3 20 FF=448.00 8' SIDEWALK 8' DEDICATED R/W \ \ \ 1 \ \ \ \ 1 \ \ \ \ \ \ \ \ \ \ 1 \ \ \ \ \ 1 \ \ \ \ \ \ l \ \ \ \ \ ------------— — — — — — — — — — — — — — — — — I N 275 LF, 8" 0 PVC SS N 35+00 ® S=4.99% 3 — FO FO FO �--�c} FO 29 0 N 36+00 0087000028 BENSON ROAD S (MINOR ARTERIAL) 16 FF=454.70 SSMH #4, TYPE 1-48"0 STA, 36+39.74, 26.00' LT. RIM=447.15 IE OUT=439.15 8" 0 NW i FO FO FO y 00 �L 1 36+89 QD L0 Cy) Q0 +� I o � �i � 00 445 EXISTING GRADE @ — PROPOSED 8` S.D. 440 _- -- 435 ss16 _ i 4.30 SSMH 4 TY'PE 1-48" 0 _ STA. 36+39.74, 26.00' LT. e� IMOUT 7 -15 E439.15 8"0 NW 425 GM, 415 Cal 2 Working Days Before You Dig 811 U01m Undergrotnd Location Center (D,MT,PD,OR,WA) SSMH 3 TYPE 1 —48"0 STA. 10+2_4.88, 23.50' RT. RIM=434.06 IE IN=425.42 8"0 SE IE OUT=4 25.32, 8" NH' CONTRACTOR TO VERIFY SIZE AND DEPTH PRIOR TO CONSTRUCTION, AND NOTIFY ENGINEER OF ANY DISCREPANCIES 34+00 CONSULTING ENGINEERS L L C Osth Avenue South 10 1 * (4&1 Suite 205 Federal Way, WA 98003 FEDERAL WAY (253) e3"113 www.esmcivil.com EVERETT (425) 297 99- ELLENSBURG (509) 962-26a8 Civil Engineering Land Surveying Land Planning Public Works I Project Management I Landscape Architecture ESM JOB # 1670-004-013 35+00 �Ndo Kai - ���� 0 FIRST SUBMITTAL - �; r SECOND SUBMITTAL_ MYLAR SUBMITTAL 51088 c/� ��DAfAL 36+00 ESM 02/11/14 SURVEYED: SCALE: 1 rs40• ESM 04 15 14 DESIGNED: ESM 05/12/14 DRAWN: at ONE NCH CHECKED AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY REVISION BY DATE AP P R APPROVED: FO NA SCALE: 1 "=20' HORIZ. 1 "=5' VERT. 20 10 0 20 40 0087000220 S=3 72 902 37+00 HORIZONiALL NAD 1983/1991 0 �- CITY OF It— RENTON DATUM Planning/Building/Public Works Dept. S 28TH ST KEY MAP NOTES: 1. SEE SHEET HC-01 FOR HORIZONTAL CURVE DATA. 2. EXISTING DRY UTILITIES SHALL BE REMOVED OR RELOCATED BY THE APPROPRIATE UTILITY COMPANIES AND COORDINATED WITH THE CONTRACTOR. NOTIFY THE ENGINEER OF ANY DISCREPANCIES. 3. CONTRACTOR SHALL RECORD ANY FIELD DEVIATION FROM THE ENGINEERING PLANS. THESE RECORDS SHALL BE KEPT ON CONSTRUCTION DRAWINGS AND TURNED OVER TO THE ENGINEER UPON COMPLETION OF THE PROJECT. 4. STREET NAME SIGNS AND STOP SIGNS TO BE INSTALLED PER CITY OF RENTON STANDARDS G012 & G013. FINAL LOCATIONS TO BE DETERMINED DURING CONSTRUCTION BY THE CITY. SIGNS WILL NEED TO BE INSTALLED PRIOR TO AS—BUILTS AND COMPLETION OF CONSTRUCTION. 5. ALL TRENCH RESTORATION SHALL BE PER THE CURRENT CITY OF RENTON TRENCH RESTORATION AND STREET OVERLAY DETAIL. ALLOWABLE PIPE MATERIALS 1. REINFORCED CONCRETE PIPE 2. DUCTILE IRON (WATER SUPPLY, CLASS 50 OR 52) 3. SOLID WALL POLYETHYLENE PIPE (SWPE; ALSO KNOWN AS HDPE PIPE OR HDPP) 4. CORRUGATED POLYETHYLENE PIPE (CPEP) 445 440 435 430 425 CHECKED FOR COMPLIANCE TO CITY STANDARDS �' �� �-� S '/f • Z of � DATE: LaRosa 05/12/201 SANITARY SEWER PLAN AND PROFILE FiELDB00K: PAGE: DRAWING NO: SS-01 SHEET: 22 OF: