HomeMy WebLinkAboutTRO4103732.1NE 114, NW 114, SEC.14, TWP.. 3N., RGE.. 5E , W.M.
MATCH LINE STA 0+50
SEE SHEET I L2
4
R f W _,
MATCH LINE STA 20+75
SEE SHEET I L2
C3
� 0
Zam
J Q
ILLUMINATION LEGEND
EXISTING NEW DESCRIPTION
I
P
m 0 JUNCTION BOX TYPE 1, 2
STANDARD DAVIT POLE
DECORATIVE POLE
- - - - - CONDUIT/CONDUCTOR
ER3 SERVICE CABINET
0 CONSTRUCTION NOTE
0 LUM. POLE NO.
WIRE NOTE
ILLUMINATION CONSTRUCTION NOTES
i INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION
POLE SCHEDULE, SHEET IL1.1, AND PER CITY OF RENTON STD PLANS 115, 119,
120, 121, & JO13.
INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION
POLE SCHEDULE, SHEET IL 1. 1, AND PER CITY OF RENTON STD PLANS 1 16.1, 119,
120, & 121.
CONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLAN 126.1. 3
FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1 &
123. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE
VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS.
(4)EXISTING STREET LIGHT POLE TO REMAIN.
POWER SOURCE CONNECTION POINT UNKNOWN AT THE TIME OF PLAN
5
PREPARATION. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC
REQUIREMENTS. PSE TO PROVIDE 1201240 VOLT SINGLE PHASE POWER SOURCE.
CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL
HOOK-UP, SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY
ALL ASSOCIATED FEES.
ILLUMINATION
POLE SCHEDULE
LUM.
POLE I.D.
*
MOUNT.
ARM
SERVICE/
WATTAGE
LUMINAIRE TYPE-----
BASE
COMMENT
POLE NO.
STREET
NO
STATION
1OFFSET
HEIGHT
VOLTAGE
LENGTH
CIRCUIT
TYPE
DISTRIBUTION
SE 132 ST !
-
11+33.5
16.5'
LT
25'
240
8'
ILLUM A
94
LED
ATB2 40BLEDE70R3 NL
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
115,
DRlVERT
2
SE 132 ST
-
13+14.0
16.5'
LT
25'
240
8'
i ILLUM A
94
LED
AT82 40BLEDE70 MVOLT R3 NL
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
115
700mA DRIVER
3
SE 132 ST
-
14+87.5
16.5'
LT
25'
240
8'
ILLUM A
94
LED
ATB2 4DBLEDER3 NL
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
115.
00mA DRIVVERR
700mA
7
SE 132 ST
-
16+02.0
16.5'
LT
25'
240
$'
ILLUM A
94
LED
ATB2 40BLEDE70 MVOLT R3 NL
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
115. I
700mA DRIVER
5
ROSARIO AVE NE
1+11.5
15.0'
RT
14'
240
-
ILLUM B
44
LED
PRESTIGE
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
116.1.
CY17T4-VS3AR-3L-44W-4K
i
NE 2 LANE
-
30+46.5
, 12.5'
LT
14'
240
-
ILLUM B
44
LED
PRESTIGE
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
116. 1.
CY17T4--VS3AR-3L-44W-4K
` 7
NE 2 LANE
-
31 +45.0
' 12.5'
RT
14'
240
-
ILLUM B
44
LED
PRESTIGE
CY17T4-VS3AR--3L-44W-4K
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
1 16. 1.
NE 2 LANE
_ -
32+43.0
12.5'
LT
14'
240
ILLUM B
44
LED
PRESTIGE
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
1 16.1.
CY17T4-VS3AR-3L-44W-4K
NE 2 LANE
` -
33+37.5
12.5'
RT
14'
240
-
ILLUM B
44
LED
PRESTIGE
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
116.1.
CY17T4-VS3AR-3L-44W--4K
10
NE 2 LANE
-
34+32.0
12.5'
LT
14'
240
-
ILLUM B
44
LED
PRESTIGE
CY 17T4-VS3AR-3L-44W-4K
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
116.1.
11
SHADOW AVE NE
-
22+91.0
16.5'
LT
14'
240
-
_
ILLUM B
44
LED
PRESTIGE
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
116. 1.
CY17T4-VS3AR-3L-44W-4K
Q12
SHADOW AVE NE
-
21+95.5
16.5'
RT
14'
240
-
ILLUM B
44
LED
PRESTIGE
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
116.1.
CY17T4--VS3AR-3L-44W 4K
13
SHADOW AVE NE
-
21 +08.5
; 16.5'
LT
14'
24D
-
ILLUM B
44
LED
PRESTIGE
FIXED
NEW
POLE
PER
RENTON
STD
PLAN
116.1.
CY17T4-VS3AR-3L-44W-4K
* STATIONS/OFFSETS ARE APPROXIMATE.
CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH ENGINEER PRIOR TO IMPLEMENTING.
** TO BE NUMBERED AT THE TIME OF CONSTRUCTION.
ILLUMINATION WIRING SCHEDULE
j�
RACEWAY
SIZE CONDUIT
ILLUM.
#8
EQUIP.
G #S
PULL
WIRE
SERVICE
#2
NO.
1
2" SCH40 PVC
2
1
2" SCH40 PVC SPARE
1
2
2" SCH80 PVC
2
1
2" SCH80 PVC (SPARE)
1
3
12" SCH40 PVC
2
1
4
2„ SCH80 PVC
3
5
2" SCH40 PVC
4
1
6
2" SCH80 PVC
2
1
* OTHER CONDUIT MAY BE PRESENT
14& dl� '/s_//
10 40
1
0 20 60
SCALE IN FEET
Tm373201
a
b
rn�
C�d
4&
cr
a
cn