Loading...
HomeMy WebLinkAboutTRO4103732.1NE 114, NW 114, SEC.14, TWP.. 3N., RGE.. 5E , W.M. MATCH LINE STA 0+50 SEE SHEET I L2 4 R f W _, MATCH LINE STA 20+75 SEE SHEET I L2 C3 � 0 Zam J Q ILLUMINATION LEGEND EXISTING NEW DESCRIPTION I P m 0 JUNCTION BOX TYPE 1, 2 STANDARD DAVIT POLE DECORATIVE POLE - - - - - CONDUIT/CONDUCTOR ER3 SERVICE CABINET 0 CONSTRUCTION NOTE 0 LUM. POLE NO. WIRE NOTE ILLUMINATION CONSTRUCTION NOTES i INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL1.1, AND PER CITY OF RENTON STD PLANS 115, 119, 120, 121, & JO13. INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL 1. 1, AND PER CITY OF RENTON STD PLANS 1 16.1, 119, 120, & 121. CONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLAN 126.1. 3 FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1 & 123. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. (4)EXISTING STREET LIGHT POLE TO REMAIN. POWER SOURCE CONNECTION POINT UNKNOWN AT THE TIME OF PLAN 5 PREPARATION. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 1201240 VOLT SINGLE PHASE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK-UP, SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES. ILLUMINATION POLE SCHEDULE LUM. POLE I.D. * MOUNT. ARM SERVICE/ WATTAGE LUMINAIRE TYPE----- BASE COMMENT POLE NO. STREET NO STATION 1OFFSET HEIGHT VOLTAGE LENGTH CIRCUIT TYPE DISTRIBUTION SE 132 ST ! - 11+33.5 16.5' LT 25' 240 8' ILLUM A 94 LED ATB2 40BLEDE70R3 NL FIXED NEW POLE PER RENTON STD PLAN 115, DRlVERT 2 SE 132 ST - 13+14.0 16.5' LT 25' 240 8' i ILLUM A 94 LED AT82 40BLEDE70 MVOLT R3 NL FIXED NEW POLE PER RENTON STD PLAN 115 700mA DRIVER 3 SE 132 ST - 14+87.5 16.5' LT 25' 240 8' ILLUM A 94 LED ATB2 4DBLEDER3 NL FIXED NEW POLE PER RENTON STD PLAN 115. 00mA DRIVVERR 700mA 7 SE 132 ST - 16+02.0 16.5' LT 25' 240 $' ILLUM A 94 LED ATB2 40BLEDE70 MVOLT R3 NL FIXED NEW POLE PER RENTON STD PLAN 115. I 700mA DRIVER 5 ROSARIO AVE NE 1+11.5 15.0' RT 14' 240 - ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K i NE 2 LANE - 30+46.5 , 12.5' LT 14' 240 - ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116. 1. CY17T4--VS3AR-3L-44W-4K ` 7 NE 2 LANE - 31 +45.0 ' 12.5' RT 14' 240 - ILLUM B 44 LED PRESTIGE CY17T4-VS3AR--3L-44W-4K FIXED NEW POLE PER RENTON STD PLAN 1 16. 1. NE 2 LANE _ - 32+43.0 12.5' LT 14' 240 ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 1 16.1. CY17T4-VS3AR-3L-44W-4K NE 2 LANE ` - 33+37.5 12.5' RT 14' 240 - ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W--4K 10 NE 2 LANE - 34+32.0 12.5' LT 14' 240 - ILLUM B 44 LED PRESTIGE CY 17T4-VS3AR-3L-44W-4K FIXED NEW POLE PER RENTON STD PLAN 116.1. 11 SHADOW AVE NE - 22+91.0 16.5' LT 14' 240 - _ ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116. 1. CY17T4-VS3AR-3L-44W-4K Q12 SHADOW AVE NE - 21+95.5 16.5' RT 14' 240 - ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4--VS3AR-3L-44W 4K 13 SHADOW AVE NE - 21 +08.5 ; 16.5' LT 14' 24D - ILLUM B 44 LED PRESTIGE FIXED NEW POLE PER RENTON STD PLAN 116.1. CY17T4-VS3AR-3L-44W-4K * STATIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ADJUSTMENTS WITH ENGINEER PRIOR TO IMPLEMENTING. ** TO BE NUMBERED AT THE TIME OF CONSTRUCTION. ILLUMINATION WIRING SCHEDULE j� RACEWAY SIZE CONDUIT ILLUM. #8 EQUIP. G #S PULL WIRE SERVICE #2 NO. 1 2" SCH40 PVC 2 1 2" SCH40 PVC SPARE 1 2 2" SCH80 PVC 2 1 2" SCH80 PVC (SPARE) 1 3 12" SCH40 PVC 2 1 4 2„ SCH80 PVC 3 5 2" SCH40 PVC 4 1 6 2" SCH80 PVC 2 1 * OTHER CONDUIT MAY BE PRESENT 14& dl� '/s_// 10 40 1 0 20 60 SCALE IN FEET Tm373201 a b rn� C�d 4& cr a cn